background image

Precautions

 

This product is designed to control DecaLED

• 

®

 24V products and may not be used in conjunction with other 

appliances. 

Never open the housing without removing the power supply. Some parts may still powered. 

• 

Only qualified personnel may open the housing. 

• 

The DecaLED

• 

®

 Controller 3 Mini is only suited for indoor use. 

Check the DecaLED

• 

®

 Controller 3 Mini for visible damage before use. 

Never exceed the maximum allowed amount of strips to connect and choose a high quality connection 

• 

cord. 

Do  not  cover  the  ventilation  area  on  the  backside  of  the  device.  The  cooling  area  may  reach  high 

• 

temperatures, so make sure there is enough room for ventilation. Do not put other devices on top of or 

behind this device. 

If you find a defect, immediately turn off the device and contact your distributor. 

• 

Do not insert objects into the ventilation openings. 

• 

Do not use this device in humid environments. 

• 

Do not use this device in environments with strong magnetic fields and strongly polluted and/or dusty 

• 

rooms. 

All directions for installation and usage that are applicable to this product must be observed. Only let 

• 

qualified personnel work on electric connections and service. 

Cleaning

 

Only clean the product when the device is disconnected from the power supply. 

• 

Use a dry and smooth cloth for cleaning. 

• 

Do not use aggressive chemicals. 

• 

Do not let liquids penetrate the device. 

• 

Never use sharp objects when cleaning. 

• 

Warranty

This product is guaranteed to have no defects as a result of material and manufacturing mistakes for a 

• 

period of one year after the date of purchase. 

This guarantee only comprises parts that have broken down and repairing costs. 

• 

Repairing will only be done under warranty if it is convincingly proven (for example by way of an invoice) 

• 

that the day on which the complaint has been filed is within the guarantee period. 

The manufacturer cannot be held liable when the defect has occurred as a result of improper use, bad 

maintenance, use in an unsuitable environment or when repairs have been made by unqualified personnel. 

Controls and functions

Front Panel View 

1. Power adapter input, 100-240VAC, 50/60Hz, 100W

2. Fuse holder Use only with a 250V fuse

3. Power switch ON/OFF 

Power

DMX

1

DMX out

Controller 3 Mini for 24V

Product code: 95350246

IR

IR

EXT. Sensor

2

1

2

3

4

B

R G

+

DMX in

1 = Ground; 2 = Data - ; 3 = Data +

Max. Total 100W

Max. 70W per output

on

D

M

X

A

d

d

re

s

s

S

e

tt

in

g

1

2

3

4

5

6

7

8

9

0

1

2

4

8

16

32

64

128

256

Stand alone

(Dipswitch 10 = OFF)

1 - 3 Fade time
4 - 6 Speed
7 - 9 Program

Setup Tool

1

2

3

Made in PRC

CAUTION:
DO NOT OPEN!

CAUTION:

RISK OF ELECTRIC SHOCK

THIS UNIT MUST BE GROUNDED

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR!
METTRE CETTE APPAREIL A LA MASSE

Serial Number:

POWER

www.decaled.com

POWER IN:

100-240V

50/60Hz 100W

AC,

Product code: 95350246

Controller 3 Mini

for 24V

FUSE:

T2.5A 250V 5x20mm

Rear Panel View

1.
Green LED (flashing) indication for DMX signal.
Quick flashing: an DecaLED

Setup tool is updating.

Slow flashing: DMX signal active.
2.
Red LED (power) indication for presence of tension.
3.

(3-pin XLR socket / Terminal Strip)

XLR chassis part male, 3-polar for DMX connection.
4.
XLR chassis part female, 3-polar for DMX Output.

DMX LED

Power LED

DMX / Programming input

DMX output (connection) (3-pin XLR socket / Terminal Strip)

5. 24
4-polar terminal strips*2pcs for connecting DecaLED RGB modules(24V DC).

Never connect the DMX signal and the Setup Tool to an XLR 3-polar input or output simultaneously.

This can severely damage your DecaLED Controller 3 Mini for 24V.
6.
7.

To connect an external connected IR EYE sensor

8.
To set work modes and relative parameters

V DC outputs

Built-in IR sensor
IR in
10-digit Addressing Dip Switch & 2-digit Function Dip Switch

Note:

R

R

R

Controls & Functions:

1.

AC100~240V, 50/60Hz

2.

Use only with a 250V fuse

3.

ON/OFF

Power input
Fuse holder
Power switch

Front Panel View

1

2

3

1 2

3

4

3

4

5

6

7

8

Physical Dimensions:

-Page 3-

Summary of Contents for 95350246

Page 1: ... DecaLED Setup Tool Control Mode available in Slave Control mode DMX Mode and Master mode In DMX Mode allows to configure different load output modes as needed consisting of RGB mode Color mode Color Brightness mode and Single mode In Master Mode available in Manual Mode and Auto Mode allows to select 1 10 patterns plus a sequence of 10 patterns with chase speed fade time In Full DMX Control Mode ...

Page 2: ... objects when cleaning Warranty This product is guaranteed to have no defects as a result of material and manufacturing mistakes for a period of one year after the date of purchase This guarantee only comprises parts that have broken down and repairing costs Repairing will only be done under warranty if it is convincingly proven for example by way of an invoice that the day on which the complaint ...

Page 3: ...ut connection 3 pin XLR socket Terminal Strip 5 24 4 polar terminal strips 2pcs for connecting DecaLED RGB modules 24V DC Never connect the DMX signal and the Setup Tool to an XLR 3 polar input or output simultaneously This can severely damage your DecaLED Controller 3 Mini for 24V 6 7 To connect an external connected IR EYE sensor 8 To set work modes and relative parameters V DC outputs Built in ...

Page 4: ...Maximum amount of connected A maximum of 6 channels 2x RGB channels can be controlled separately O 2 Connector configuration The DMX configuration is depicted below The DMX connections consist of one XLR 3 male connector input and one XLR 3 female connector transited output or 3 polar terminal connector DecaLED RGB modules 24V nly a maximum loading capacity of 3A 1A per individual channel is allow...

Page 5: ...Controller 2 Mini for 12V RGB modules For further information please refer to its accompanying manual 1 1 Slave Control DMX Mode DecaLED Setup Tool Control Mode enables In this mode the Dip Switch 11 2 is flipped to the position and R G B output loading is set by default digit Function Dip Switch ON 1 2 4 5 3 6 Group 1 Group 2 Color R G B Channel 1 6 Group 1 2 Output 1 Output 2 Red Blue MODE 1 RGB...

Page 6: ...e driver will keep the last received DMX signal information until the driver is switched off or a new and valid DMX signal is sent 4 When in link the Slave will follow the Master all parameter settings of each slave connected unit will be of no effect 1 2 Master Control 1 AUTO mode 2 MANUAL mode AUTO mode and MANUAL mode are for Master Control Relevant functions are as below Preset programs 1 10 p...

Page 7: ... the different dipswitches that will add up to the value you wish to achieve for example Setting DMX address for 21 Flip switches1 3 5 to the ON position Setting DMX address for 201 Flip switches1 4 7 8 to the ON position Dipswitches Value 1 1 3 4 5 16 21 Dipswitches Value 1 1 4 8 7 64 8 128 201 In this mode the Dip Switch 11 2 is flipped to the position the Dip Switch 10 is to the position And th...

Page 8: ... Addressing Dip Switch to the OFF position Flip the dip switch 1 3 10 digit Addressing Dip Switch to set up fade time the dip switch 4 6 10 digit Addressing Dip Switch to select chase speed and the dip switch 7 9 10 digit Addressing Dip Switch to select built in 8 patterns Their details can be referred to the below table 0 OFF position 1 ON position 000 100 010 110 001 101 011 111 0 100 1 2 3 14 2...

Page 9: ... 2S 8 4S 7 8S 6 16S 5 4 3 2 1 32 5S 65S 130S 260S 512S 3 And fade time is available from 0 through 100 total 11levels 10 per level Page 11 4 Effective distance from IR sensor to LED Remote shall be limited within the range of 10m Otherwise it results out of control Pushbuttons Keys Functions RED pushbutton GREEN pushbutton BLUE pushbutton CYAN pushbutton MAGENTApushbutton YELLOW pushbutton WHITE p...

Page 10: ...orrectly by means of the DecaLED Setup Tool The connected DecaLED 24V products do not respond Check that the output cables and all connections have been connected correctly If necessary remove all outputs except 1 Only a maximum loading capacity of 3A 1A per individual channel is allowed on a single output and the maximum amount of the total load can not exceed 4A distributed over all 2 outputs Th...