Connecting the power supply

Check whether or not the source voltage in your area matches the required voltage for the controller power 

supply. Note: If the source voltage is 110V, do NOT connect a 230V power supply. This can severely damage 

your device. The DecaLED

®

 Controller 3 Mini is supplied with a power cable. The device is powered by an 

IEC cord which fits into the power adapter (1) on the backside of the device. Keep pushing the IEC until it is 

fixed into position in the adapter. The device can be turned on by using the power switch. An indicator shows 

whether the device is turned on or off. 

Connecting the DecaLED

®

 24V products to the DecaLED

®

 Controller 3 Mini. 

Configuration 

1. Maximum amount of connected DecaLED

®

 24V products

A  maximum  of  6  channels  (2x  RGB  channels)  can  be  controlled  separatelyseparately,  only  a  maximum 

loading capacity of 3A(1A per individual channel) is allowed on a single output and the maximum amount of 

the total load can not exceed 4A distributed over all 2 outputs.

2. Connector configuration

The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) 

and one XLR 3 female connector (transited output) or 3-polar terminal connector.

The XLR 3-polar connector:   1 = ground, 2 = data -, 3 = data +

3. Connector configuration outputs - The output configuration is depicted below. The output connections 

consist of eight 5-polar terminal connectors. 

The 4-polar terminal connector: 

1 = +

2 = R

3 = G

4 = B

A 120 ohm impedance DMX signal cable MUST be used for signal connection. 

Configuration:

1. Maximum amount of connected 
A maximum of 24 channels (8x RGB channels) can be controlled separately. The maximum amount of connected 
DecaLED   RGB modules must not exceed 250. Please note: only 50 modules are allowed on a single output.

2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and 
one XLR 3 female connector (transited output) or 3-polar terminal connector .

DecaLED   RGB modules

The XLR 3-polar connector:  1 = GROUND

2 = DATA -
3 = DATA + 

Chassis part XLR-3 male    Chassis part XLR-3 female

The 5-polar terminal connector: 

3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 5-polar terminal connectors.

5-polar terminal connector

R

R

3-polar terminal connector

1 = Blue
2 = Red
3 = Green
4 = White
5 = Yellow

NOTE:
DMX signal cable

: 120 ohm impedance DMX signal cable 

MUST

 be used for signal connection.

Connecting the Tension Provider

Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device. 
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power 
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The 
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.

Connecting the DecaLED   RGB modules to the DecaLED   Controller 1 for RGB modules

Only 50pcs DecaLED   RGB  modules 
are allowed on a single output and the 
maximum amount of connected modules 
can not exceed 250pcs. 

R

DMX Controller

A LED Setup Tool

(XB-R1)

Or

DecaLED  Controller 1

for RGB modules

(A Driver Unit)

DMX out

DMX in

R

R

R

IR EYE(Sensor)

LED REMOTE

IR In

-Page 5-

Configuration:

1. Maximum amount of connected
A maximum of 6 channels (2x RGB channels) can be controlled separately. O

2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .

DecaLED RGB modules(24V)

nly a maximum loading capacity of

3A(1A per individual channel) is allowed on a single output and the maximum amount of the total load can not
exceed 4.5A distributed over all 2 outputs.

The XLR 3-polar connector: 1 = GROUND

2 = DATA -
3 = DATA +

Chassis part XLR-3 male

Chassis part XLR-3 female

The 4-polar terminal connector:

3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.

4-polar terminal connector

R

3-polar terminal connector

1 = +
2 = R
3 = G
4 = B

NOTE:
DMX signal cable

MUST

: 120 ohm impedance DMX signal cable

be used for signal connection.

Connecting the Tension Provider

The device is powered by an IEC cord which fits into the power socket on the backside of the device. Keep pushing
the IEC until it is fixed into position in the socket. The device can be turned on by means of the power switch. An
indicator shows whether the device is turned on or off.

Connecting the DecaLED RGB modules(24V) to the DecaLED Controller 3 Mini for 24V

DMX Controller

DecaLED Setup Tool

Or

DecaLED Controller 3 Mini

for 24V

(A Driver Unit)

DMX out

DMX in

R

R

R

Only a maximum loading capacity of 3A(1A
per individual channel) is allowed on a single
output and the maximum amount of the total
load can not exceed 4.5A distributed over all
2 outputs.

-Page 4-

IR EYE(Sensor)

LED REMOTE

IR In

R

Configuration:

1. Maximum amount of connected 
A maximum of 24 channels (8x RGB channels) can be controlled separately. O

2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and 
one XLR 3 female connector (transited output) or 3-polar terminal connector .

DecaLED   RGB modules(12V)

nly a maximum loading capacity of 

3A(1A per individual channel)  is allowed on a single output and the maximum amount of the total load can not 
exceed 12A distributed over all 8 outputs.

The XLR 3-polar connector:  1 = GROUND

2 = DATA -
3 = DATA + 

Chassis part XLR-3 male    Chassis part XLR-3 female

The 4-polar terminal connector: 

3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.

4-polar terminal connector

R

3-polar terminal connector

1 = +
2 = R
3 = G
4 = B

NOTE:
DMX signal cable

: 120 ohm impedance DMX signal cable 

MUST

 be used for signal connection.

Connecting the Tension Provider

Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device. 
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power 
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The 
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.

Connecting the DecaLED   RGB modules(12V) to the DecaLED   Controller 2 for 12V

DMX Controller

A LED Setup Tool

(XB-R1)

Or

DecaLED  Controller 2

for 12V

(A Driver Unit)

DMX out

DMX in

R

R

R

Only a maximum loading capacity of 3A(1A 
per individual channel) is allowed on a single 
output and the maximum amount of the total 
load can not exceed 12A distributed over all 
8 outputs.

IR EYE(Sensor)

LED REMOTE

IR In

-Page 5-

Summary of Contents for 95350246

Page 1: ... DecaLED Setup Tool Control Mode available in Slave Control mode DMX Mode and Master mode In DMX Mode allows to configure different load output modes as needed consisting of RGB mode Color mode Color Brightness mode and Single mode In Master Mode available in Manual Mode and Auto Mode allows to select 1 10 patterns plus a sequence of 10 patterns with chase speed fade time In Full DMX Control Mode ...

Page 2: ... objects when cleaning Warranty This product is guaranteed to have no defects as a result of material and manufacturing mistakes for a period of one year after the date of purchase This guarantee only comprises parts that have broken down and repairing costs Repairing will only be done under warranty if it is convincingly proven for example by way of an invoice that the day on which the complaint ...

Page 3: ...ut connection 3 pin XLR socket Terminal Strip 5 24 4 polar terminal strips 2pcs for connecting DecaLED RGB modules 24V DC Never connect the DMX signal and the Setup Tool to an XLR 3 polar input or output simultaneously This can severely damage your DecaLED Controller 3 Mini for 24V 6 7 To connect an external connected IR EYE sensor 8 To set work modes and relative parameters V DC outputs Built in ...

Page 4: ...Maximum amount of connected A maximum of 6 channels 2x RGB channels can be controlled separately O 2 Connector configuration The DMX configuration is depicted below The DMX connections consist of one XLR 3 male connector input and one XLR 3 female connector transited output or 3 polar terminal connector DecaLED RGB modules 24V nly a maximum loading capacity of 3A 1A per individual channel is allow...

Page 5: ...Controller 2 Mini for 12V RGB modules For further information please refer to its accompanying manual 1 1 Slave Control DMX Mode DecaLED Setup Tool Control Mode enables In this mode the Dip Switch 11 2 is flipped to the position and R G B output loading is set by default digit Function Dip Switch ON 1 2 4 5 3 6 Group 1 Group 2 Color R G B Channel 1 6 Group 1 2 Output 1 Output 2 Red Blue MODE 1 RGB...

Page 6: ...e driver will keep the last received DMX signal information until the driver is switched off or a new and valid DMX signal is sent 4 When in link the Slave will follow the Master all parameter settings of each slave connected unit will be of no effect 1 2 Master Control 1 AUTO mode 2 MANUAL mode AUTO mode and MANUAL mode are for Master Control Relevant functions are as below Preset programs 1 10 p...

Page 7: ... the different dipswitches that will add up to the value you wish to achieve for example Setting DMX address for 21 Flip switches1 3 5 to the ON position Setting DMX address for 201 Flip switches1 4 7 8 to the ON position Dipswitches Value 1 1 3 4 5 16 21 Dipswitches Value 1 1 4 8 7 64 8 128 201 In this mode the Dip Switch 11 2 is flipped to the position the Dip Switch 10 is to the position And th...

Page 8: ... Addressing Dip Switch to the OFF position Flip the dip switch 1 3 10 digit Addressing Dip Switch to set up fade time the dip switch 4 6 10 digit Addressing Dip Switch to select chase speed and the dip switch 7 9 10 digit Addressing Dip Switch to select built in 8 patterns Their details can be referred to the below table 0 OFF position 1 ON position 000 100 010 110 001 101 011 111 0 100 1 2 3 14 2...

Page 9: ... 2S 8 4S 7 8S 6 16S 5 4 3 2 1 32 5S 65S 130S 260S 512S 3 And fade time is available from 0 through 100 total 11levels 10 per level Page 11 4 Effective distance from IR sensor to LED Remote shall be limited within the range of 10m Otherwise it results out of control Pushbuttons Keys Functions RED pushbutton GREEN pushbutton BLUE pushbutton CYAN pushbutton MAGENTApushbutton YELLOW pushbutton WHITE p...

Page 10: ...orrectly by means of the DecaLED Setup Tool The connected DecaLED 24V products do not respond Check that the output cables and all connections have been connected correctly If necessary remove all outputs except 1 Only a maximum loading capacity of 3A 1A per individual channel is allowed on a single output and the maximum amount of the total load can not exceed 4A distributed over all 2 outputs Th...

Reviews: