Connecting the power supply
Check whether or not the source voltage in your area matches the required voltage for the controller power
supply. Note: If the source voltage is 110V, do NOT connect a 230V power supply. This can severely damage
your device. The DecaLED
®
Controller 3 Mini is supplied with a power cable. The device is powered by an
IEC cord which fits into the power adapter (1) on the backside of the device. Keep pushing the IEC until it is
fixed into position in the adapter. The device can be turned on by using the power switch. An indicator shows
whether the device is turned on or off.
Connecting the DecaLED
®
24V products to the DecaLED
®
Controller 3 Mini.
Configuration
1. Maximum amount of connected DecaLED
®
24V products
A maximum of 6 channels (2x RGB channels) can be controlled separatelyseparately, only a maximum
loading capacity of 3A(1A per individual channel) is allowed on a single output and the maximum amount of
the total load can not exceed 4A distributed over all 2 outputs.
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input)
and one XLR 3 female connector (transited output) or 3-polar terminal connector.
The XLR 3-polar connector: 1 = ground, 2 = data -, 3 = data +
3. Connector configuration outputs - The output configuration is depicted below. The output connections
consist of eight 5-polar terminal connectors.
The 4-polar terminal connector:
1 = +
2 = R
3 = G
4 = B
A 120 ohm impedance DMX signal cable MUST be used for signal connection.
Configuration:
1. Maximum amount of connected
A maximum of 24 channels (8x RGB channels) can be controlled separately. The maximum amount of connected
DecaLED RGB modules must not exceed 250. Please note: only 50 modules are allowed on a single output.
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male Chassis part XLR-3 female
The 5-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 5-polar terminal connectors.
5-polar terminal connector
R
R
3-polar terminal connector
1 = Blue
2 = Red
3 = Green
4 = White
5 = Yellow
NOTE:
DMX signal cable
: 120 ohm impedance DMX signal cable
MUST
be used for signal connection.
Connecting the Tension Provider
Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device.
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules to the DecaLED Controller 1 for RGB modules
Only 50pcs DecaLED RGB modules
are allowed on a single output and the
maximum amount of connected modules
can not exceed 250pcs.
R
DMX Controller
A LED Setup Tool
(XB-R1)
Or
DecaLED Controller 1
for RGB modules
(A Driver Unit)
DMX out
DMX in
R
R
R
IR EYE(Sensor)
LED REMOTE
IR In
-Page 5-
Configuration:
1. Maximum amount of connected
A maximum of 6 channels (2x RGB channels) can be controlled separately. O
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules(24V)
nly a maximum loading capacity of
3A(1A per individual channel) is allowed on a single output and the maximum amount of the total load can not
exceed 4.5A distributed over all 2 outputs.
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male
Chassis part XLR-3 female
The 4-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.
4-polar terminal connector
R
3-polar terminal connector
1 = +
2 = R
3 = G
4 = B
NOTE:
DMX signal cable
MUST
: 120 ohm impedance DMX signal cable
be used for signal connection.
Connecting the Tension Provider
The device is powered by an IEC cord which fits into the power socket on the backside of the device. Keep pushing
the IEC until it is fixed into position in the socket. The device can be turned on by means of the power switch. An
indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules(24V) to the DecaLED Controller 3 Mini for 24V
DMX Controller
DecaLED Setup Tool
Or
DecaLED Controller 3 Mini
for 24V
(A Driver Unit)
DMX out
DMX in
R
R
R
Only a maximum loading capacity of 3A(1A
per individual channel) is allowed on a single
output and the maximum amount of the total
load can not exceed 4.5A distributed over all
2 outputs.
-Page 4-
IR EYE(Sensor)
LED REMOTE
IR In
R
Configuration:
1. Maximum amount of connected
A maximum of 24 channels (8x RGB channels) can be controlled separately. O
2. Connector configuration
The DMX configuration is depicted below. The DMX connections consist of one XLR 3 male connector (input) and
one XLR 3 female connector (transited output) or 3-polar terminal connector .
DecaLED RGB modules(12V)
nly a maximum loading capacity of
3A(1A per individual channel) is allowed on a single output and the maximum amount of the total load can not
exceed 12A distributed over all 8 outputs.
The XLR 3-polar connector: 1 = GROUND
2 = DATA -
3 = DATA +
Chassis part XLR-3 male Chassis part XLR-3 female
The 4-polar terminal connector:
3. Connector configuration outputs
The output configuration is depicted below. The output connections consist of eight 4-polar terminal connectors.
4-polar terminal connector
R
3-polar terminal connector
1 = +
2 = R
3 = G
4 = B
NOTE:
DMX signal cable
: 120 ohm impedance DMX signal cable
MUST
be used for signal connection.
Connecting the Tension Provider
Check whether or not the source Voltage in your area matched the required voltage for the controller power supply.
Note: If the source Voltage is 110V, do NOT connect a 230V power supply. This can severely damage your device.
The Controller comes with a complete power cable. The device is powered by an IEC cord which fits into the power
adapter (1) on the backside of the device. Keep pushing the IEC until it is fixed into position in the adapter. The
device can be turned on by means of a power switch. An indicator shows whether the device is turned on or off.
Connecting the DecaLED RGB modules(12V) to the DecaLED Controller 2 for 12V
DMX Controller
A LED Setup Tool
(XB-R1)
Or
DecaLED Controller 2
for 12V
(A Driver Unit)
DMX out
DMX in
R
R
R
Only a maximum loading capacity of 3A(1A
per individual channel) is allowed on a single
output and the maximum amount of the total
load can not exceed 12A distributed over all
8 outputs.
IR EYE(Sensor)
LED REMOTE
IR In