6.4 Load Env (
Value)
6.4 Load Env (
Value)
Explanation: This message indicates that the envelope feeder is empty or
needs a different size envelope loaded. This message should clear when the
envelope sensor is depressed.
Signal diagram reference: See Figure 6–6.
Action: Do the following if the message appears intermittently or fails to
clear:
1.
Remove the envelope feeder and inspect the four pin connector, the pins
that align the envelope feeder, and the general area for damage. Replace
any damaged FRUs.
2.
Swap the following FRUs:
•
The envelope feeder
•
The DC control board
•
The paper feed controller board or the paper feed unit.
6–8 Power and Control Panel FIPs