background image

31

TYPE 0

1

OPERATING PARAMETERS

Electric-lock 

output 

operating: 

If=0 

“boost” 

output 

for 

electric-lock 

ar

t.1

10 

po

w

er 

supply

, If=1 

24V 

output 

contr

olled 

by 

the 

EL

OCK_

IN 

in

put 

as 

pulsed 

mo

de,If=2 

24V 

output 

contr

olled 

by 

the 

EL

OCK_IN 

in

put 

as 

st

ep-b

y-st

ep 

mode, 

If=3 

electr

o-brak

output 

for 

no

t self-lock

ing 

operat

or

s, 

If=4 

24V 

output 

fo

r electric-lock 

po

w

er 

supply 

via 

an 

ext

ernal 

rela

y, 

If=5 

24V 

output 

for 

electr

o-magne

ts 

po

w

er 

supply 

for 

barrier

s, 

If>5 

24V 

output 

contr

olled 

by 

the 

EL

OCK_IN 

in

put 

as 

tem

porized 

mode 

(the 

se

value 

indicat

es 

the 

switch-of

f dela

y in seconds).

• 000: “Boost” output f

or electric-lock ar

t.1

10 po

w

er supply

• 00

1: “2

4V 

 pulse output max 5W

• 002: “2

4V 

 st

ep-b

y-st

ep output max 5W 

• 003: “Electr

o-brak

e output f

or no

t self-locking operat

or

• 004: “Output f

or electric-lock po

w

er supply via an e

xt

ernal rela

• 005: “output f

or electr

o-magne

ts po

w

er supply f

or barrier

• >005: “2

4V 

 tem

porized output max 5W

(6sec………………255sec)

Run 

directi

on 

in

ver

sion: 

If=1 

aut

omatically

 re

ver

ses 

the 

outputs 

open/close 

of 

the 

operat

or

and 

an

opening/closing 

limit 

switches in

puts, a

voiding ha

ving t

o manual change the wiring when installing the operat

or in an in

ver

ted position.

• 000: “Standar

d installation”

• 00

1: “In

ver

ted installation”

Multiplier operations-count

er: Multiply the number of operations af

ter which the t

otal operations-count

er will be updat

ed.

To vie

w the v

alues, ref

er t

o the section “

Visualisation of in

puts and operations-count

er status”.

• 000: “

x1

00

• 00

1: “

x1

000

• 002: “

x1

0000

• 003: “

x1

00000

Maint

enance 

Operatio

ns-count

er: 

if 

rese

the 

count

er 

and 

disables 

the 

int

er

vention 

req

uest 

, if> 

indicat

es 

the 

number 

of 

ope

rations 

(x 

500) 

to 

be 

made 

bef

ore 

the 

contr

ol 

panel 

ex

ecut

es 

second 

add

itional 

pre-flash 

to 

indicat

the 

need 

of 

maint

enance.

i.g.: If P065 = 050, operations number = 50x500 = 25000 operations

W

arning:

 Bef

ore 

you 

se

t a 

ne

value 

of 

the

 count

er

-manoeuvres 

maint

enance, 

the 

same 

must 

be 

rese

t b

se

tting 

P065= 

and 

only lat

er P065 = “ne

w v

alue”.

• 000: “R

eq

uest Maint

enance disabled

• >000: “N

umber of operations (x 500) f

or req

uired maint

enance

(1

...................................255)

Selection of operating flashing light output: If=0 int

ermitt

ent flashing light output;

If=1 Fix

ed flashing light output (f

or flashing lights with int

ermitt

ent int

erior cir

cuits).

• 000: “int

ermitt

ent flashing light output

• 00

1: “fix

ed flashing light output

SAFET

Y 1

Operation 

of 

the 

SFT 

in

put: 

if 

saf

ety 

edge 

alw

ays 

enabled, 

if 

saf

ety 

edge 

enabl

ed 

only 

while 

closing, 

if 

saf

ety 

edge

 enabled 

only 

while 

closing 

and 

bef

ore 

an

mo

vement, 

if 

saf

ety 

edge 

enabled 

only 

when 

opening, 

if 

saf

ety 

edge 

enabled 

only 

while 

opening 

and 

bef

ore 

an

mo

vement; 

as 

for 

the 

obstacle 

de

tection 

with 

int

ernal 

anti-crushing 

sensor

, also 

the 

activ

ation 

of 

the 

in

puts 

SFT1 

and 

 SFT2 

causes 

the 

com

ple

te 

or 

par

tial 

re

ver

sal 

as 

se

by 

P055 

(du

ration 

of 

in

ver

sion 

on 

obstacles 

while 

opening, 

and 

P056 

(duration 

of 

re

ver

sal 

on 

obstacle 

while 

closing)

• 000: “saf

ety edge alw

ays enabled

• 00

1: “saf

ety edge enabled only while closing

• 002: “saf

ety edge enabled only while closing and bef

ore an

y mo

vement

• 003: “saf

ety edge enabled only when opening

• 004: “saf

ety edge enabled only while opening and bef

ore an

y mo

vement

SAFET

Y 2

Dela

on 

limit 

switch 

de

tection: 

the 

operation 

is 

st

opped 

af

ter 

1,5 

sec 

from 

limit 

switch 

de

tection. 

When 

during 

this 

dela

st

op 

is de

tect

ed, the operat

or is suddenly st

opped

• 000: “limit switch dela

y disabled

• 00

1: “limit switch dela

y enabled

Adjustment of acceleration durability

W

arning:

 if sof

t star

t is activ

at

ed, the acceleration is deactiv

at

ed indipendently fr

om P0

70 v

alue.

• 

000: 

“acceleration 

deactiv

at

ed 

(it 

runs 

an 

acceleration 

of 

minimum 

durability

almost im

per

ceptible)

• 00X: “adjusts the acceleration durability at 1

,5 sec (X*6 ms)

Unused parame

ter

Unused parame

ter

Unused parame

ter

Unused parame

ter

Unused parame

ter

Summary of Contents for SWINGER

Page 1: ...r portails battants Notice d emploi et avertissements Operador electromecánico para puertas con hoja batiente Instrucciones de uso y advertencias Operador electromecânico para portões de folha batente Instruções para utilização e advertências Siłownik elektromechaniczny do bram skrzydłowych Instrukcja montażu i użytkowania Электромеханический привод для распашных ворот Инструкция по эксплуатации и...

Page 2: ...The Declaration of Incorporation may be consulted by entering http www deasystem com DEA SYSTEM S p A Via Della Tecnica 6 36013 PIOVENE ROCCHETTE VI ITALY LIEVORE TIZIANO Amministratore ...

Page 3: ... K E E P T H E 230 V P O W E R S U P P LY C A B L E S A P A RT M I N I M U M 4 M M I N T H E O P E N O R 1 M M T H RO U G H I N S U L A T I O N FRO M LO W V O LTA G E C A B L E S M O TO RS P O W E R S U P P LY C O N T RO L S E L E C T RI C LO C K S A E RI A L A N D A U X I L I A RY C I RC U I T S P O W E R S U P P LY A N D FA S T E N T H E L A T T E R W I T H A P P RO P RI A T E C L A M P S N E A ...

Page 4: ...ION AND ASSEMBLY 4 1 For a satisfactory installation of the product is important to Verify that the gate complies with the legal requirements and then define the complete project of the installation Verify that the gate is well balanced and that it has no points of friction in opening and closing Identify an area that allows a smooth and safe manual operation of the operator Verify that the operat...

Page 5: ...4 15 14 Boost output for electric lock max 1 x art 110 if P062 0 24V pulse output max 5W if P062 1 step by step if P062 2 electro brake output for not self locking operators if P062 3 output for electric lock power supply via external relay if P062 4 output for electro magnets power supply for barriers if P062 5 or temporized output if P062 5 15 16 17 24 V Flashing light output max 15W art Lumy 24...

Page 6: ...llation requires different commands and or additional to the standard you can configure each input to the required rate Refer to Chapter Advanced Programming ENC M1 ENC M2 F N 1 x 1 5 mm 2 1 2 3 4 5 6 1 2 3 4 5 6 FLASH LUMY 24A S max 15W N O N O N C SAFETY Only if needed START PED TX RX TX RX COM N C N O PHOTO 2 PHOTO 1 COM N O COM N O COM N C COM N C COM N C 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2...

Page 7: ...aintenance intervention request ma noeuvres counter disabled 3 Hold down the key to display a cyclic 3 options or rele ase the button to exit the parameter 3 Selection type of operators IMPORTANT 1 Scroll down the parameters with and keys until you visua lise P028 2 Access the parameter by pressing the key 3 Verify that the value corresponds to d000 GEKO otherwise you must select it by pressing an...

Page 8: ...ning you can manually intervene by giving an impulse to Start button or pressing the OK on the control panel simulating the stroke 6 Once the procedure is ended the display will show WARNING Once you have executed the learning stroke operate a complete cycle opening closing and then check the manual release to make sure it is working properly If it s to hard increase the value of P057 of 1 or more...

Page 9: ...nly by pressing its hidden button Afterwards only transmitters personalized with the same encryption key can be memorized through the usual procedure unless a memory reset is carried out P004 8 Adjustment of operating parameters If you need to modify the operating parameters force speedness etc 1 Scroll down the parameters until you visualize the desire para meter i g P032 2 Access the parameter b...

Page 10: ...key 3 When flashes press the key 4 Release the key as soon as stops flashing Default parameters for the configuration currently in use are restored 5 At the end of the operation display returns to P007 Warning After you restore the default parameters you must program the control panel again and adjust all ope rating parameters in particular remember to properly set the configuration of parameters ...

Page 11: ... The display shows alternately the writing 4 Press the button the display shows the flashing writing 5 Press the button again and hold for 5 seconds releasing it be fore the procedure is terminated The display shows the fixed writing followed by before returning to the list of parameters 6 Access to programming is unlocked 4 Inputs configuration Where the installation requires different commands a...

Page 12: ...ccessfully Operators mouvement not detected Make sure that operators and encoders connections are well done Check that jumpers J5 and J9 are well positioned as shown on the electric wiring If this error appears again replace the control panel 9 START UP The start up phase is very important to ensure maximum security and compliance to regulations including all the requirements of EN 12445 standard ...

Page 13: ...Make sure that the electronic device for power adjustment is in good condition The operator jerks or is noisy during movement it stops mi dway or else it does not start If the leaf of the gate does not move freely release the operator and readjust the rotation points The power of the gearmotor may be insufficient for the characteristics of the gate s leaf check the choice of model whenever require...

Page 14: ...TS CONFIGURATION PARAMETERS INPUT_3 selectioning input type 000 IN3 type free contact 001 IN3 type constant resistance 8K2 INPUT_1 operating selection 000 NONE unused parameter 001 START start 002 PED pedestrian 003 OPEN separated open 004 CLOSE separated close 005 OPEN_PM man present open 006 CLOSE_PM man present close 007 ELOCK IN electric lock activation See P062 008 PHOTO 1 photocell 1 009 PHO...

Page 15: ... tot 100 tot Operators speed adjustment during slow down while closing 15 tot 100 tot Slow down duration adjustment while opening 0 tot 80 to Slow down duration adjustment while closing 0 tot 80 to Operator 1 force adjustment while opening if 100 obstacle detection deactivated 15 tot 100 tot Operator n 1 force adjustment while closing if 100 obstacle detection deactivated 15 tot 100 tot Operator n...

Page 16: ... 0 indicates the duration in seconds of the run after inversion resulting from detection of an obstacle during the opening 000 complete reversal on obstacle 000 duration of reversal on obstacle 1sec 10sec Adjust the inversion on obstacle period detected by internal anti crushing sensor or by the safety input when activated If 0 it makes a complete inversion if 0 indicates the duration in seconds o...

Page 17: ...0x500 25000 operations Warning Before you set a new value of the counter manoeuvres maintenance the same must be reset by setting P065 0 and only later P065 new value 000 Request Maintenance disabled 000 Number of operations x 500 for required maintenance 1 255 Selection of operating flashing light output If 0 intermittent flashing light output If 1 Fixed flashing light output for flashing lights ...

Page 18: ...32 ...

Page 19: ...Exclusive Australian Distributor Customer Service 03 9364 8288 See downee com au for your state office Tech Support 1800 241 733 techsupport downee com au downee com au deasystem com ...