41
8 MESSAGES SHOWN ON THE DISPLAY
WORKING STATUS MESSAGES
Mess.
Description
Gate is closed
Gate is opened
Opening under way
Closing under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop input intervened or an obstacle is detected with limited inversion duration (P055 > 0 or P056 > 0)
Board in BOOT-MODE: Indicates that the firmware is corrupted or updating. To restore the firmware, use the DEAinstaller APP and make sure
NET-NODE is corrected to the correct port.
Warning: When updating the firmware, all data in the board memory (settings and radio commands) are lost. Make sure you have backed
up the memory to be restore data after the update.
Position reset under way: the research of the closing stop (in low speed) has started
ERROR MESSAGES
Mess.
Description
Possible solutions
Board programming attempted when a NET-NODE
device is connected.
Turn off power, disconnect the NET-NODE from the communication port and turn back
on;
External photocells and/or safety devices are activated
or out of order.
- Make sure that all safety devices and/or photocells installed are working properly.
Possible fault/overheating in the control unit’s power
circuit.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
Time-out operators run: The engine/s exceeded the
maximum operating time (4min) without ever stopping.
- Give a start pulse to start the position reset procedure;
- Ensure that this operation is successful.
Time-out obstacle detection: With anti-crushing sensor
disabled, was still detected the presence of an obsta
-
cle that prevents movement of the leaf for a period of
10 seconds more.
- Make sure there are no specific frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully.
Operators mouvement not detected.
- Make sure that operators and encoders connections are well done.
- If this error appears again, replace the control panel.
No/interrupted communication with remote memory
board (also NET-EXP or NET-NODE).
- Check that the connecting cable of the external memory card is connected properly.
- If you are performing a data transfer operation (DOWNLOAD / UPLOAD), make sure
that it is not interrupted (eg by unplugging the card before the end of the operation).
Please note
:
the interruption of an UPLOAD, also involves a total RESET of the control
unit.
Possible fault/overheating in the control unit’s power
circuit.
Turn off power for several minutes and turn back on. Give a start command: if the
message is repeated, replace the control unit.
Possible malfunction in the control unit’s power circuit
or in the encoder circuit.
Check the wiring of the encoder and the motor. Shut the power supply off and on again.
Give a start command: if the message is repeated, perform the following checks.
- Enter P003 and move the door using the + and - buttons.
- If the door moves at maximum speed and the display shows Err7, replace the motor’s
encoder card.
- If the motor still remains stationary, replace the control unit.
Sensitive regulation parameters were edited via
DEAinstaller APP without running motor stroke learning
at the end of the operation.
Run motor stroke learning (P003) first to be able to run any other operation.
You are trying to learn a motor with a number of encoder
channels different than the value set in parameter
P029.
Set the parameter value P029 correctly.
NET-NODE connected to the incorrect communication
port.
Connect NET-NODE to the correct port according to that indicated in the control unit
diagram.
Summary of Contents for SPACE
Page 2: ......
Page 197: ...195 0 5 cm 4a 4b 4c 4 5a 5b ...
Page 199: ...197 7a 7b 7c 7d 7 50 mm min 180cm TLP 20 mm max 30 ...
Page 215: ......