TEST
POINT %
POINTER & DIGITAL
VOLTS (Nominal)
RECORDER
OUTPUT VOLTS
0
22.5
60
80
100
120
0.00
1.28
3.42
4.56
5.69
6.84
0.0
0.94
2.50
3.33
4.17
5.00
TOLERANCES: POINTER: + or − 0.07 Volts
Digital Readout: + or − 0.03 Volts
Recorder Output: + or − 0.03 Volts
dam01_7710112_002.cgm, cg, 10/07/03
NOTE:
The tesyt values in the table apply only when 5 volts (reference volts) is applied
to pin 5 of electrical connector 7700−P7 during calibration check. Should
reference voltage other than 5 volts be usedd, the following corrections must\
be made:
1.
Pointer Volts (Corrected) + Pointer Volts (Nom.) X Ref. Volts (Actual)
5.0 Volts
D
SERIES 100
AIRCRAFT MAINTENANCE MANUAL
TI CALIBRATION CHECK VALUES
Figure 202
MASTER
EFFECTIVITY: See Pageblock 77−10−11 page 201
77−10−11
Page 204
Dec 20/2004