readings at appropriate indicator for pointer and digital indications are within
tolerances provided in Figure 201.
(8) Connect digital voltmeter at receptacle 9811−J104 pins J and K engine (No. 1) or
pins L and M (engine No. 2) and repeat step (7) to obtain digital readings for
indicator and voltage output to Flight Data Recorder (FDR) within limits of Figure
201.
(9) Open circuit breakers, step (2) (a) or (b) and remove signal generator.
(10) Reinstall electrical connectors 6142−P6 and 9811−P104.
(11) Close circuit breakers opened in step (2).
D
SERIES 100
AIRCRAFT MAINTENANCE MANUAL
MASTER
EFFECTIVITY: See Pageblock 61−44−00 page 201
61−44−00
Page 203
Jun 20/2005