10
grill
exhaust
3" (to non-combustible
construction /
minimum lid clearance)
12" (to combustible
construction)
10-1/16"
22-3/4"
25-1/2"
3/4"
2"
13-3/4"
Standard layout for non-combustible enclosure:
NOTE: If using a backguard
apron or rear wall, locate
electrical service on the right
hand side for rotisserie motor
connection
NOTE: See Fig. 05
for ventilation notes.
28-1/2"
Bottom of
support flange
3" Min. for Lid Clearance
3" Min. for Lid
Clearance
28”
34-7/8"
28"
23-3/4"
3-1/2"
18-1/2"
20"
11-1/8"
35-1/2"
Max.
opening for access doors/drawers
(see Fig. 05 and 06 for ordering
information)
4" x 4" opening
for gas supply line
opening for access
doors/drawers
(see Fig. 05 and 06 for
ordering information)
4" x 4"
opening
for gas
supply line
22-3/4"
18-1/2"
20"
10-1/8"
35-1/2"
Max.
Layout for insulated jacket only - combustible enclosure:
NOTE: If using a backguard apron or rear
wall, locate electrical service on the right
hand side for rotisserie motor connection
WARNING!
If installing the grill into a non-combustible
enclosure, all combustible construction must still be
outside the 12 inch clearance zone. If your island is
made of stucco over the top of wooden studs, the
wood can not be inside the 12 inch clearance zone to
combustible, even though the stucco is what is
touching the grill area.
INSULATED JACKET
Size
Part No.
30
70181
INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
FIG.04