DCA SERIES HUMIDITY CONTROL SYSTEMS

LIMITED PRODUCT WARRANTY

This certificate is our warranty to you. Please insure

that you or your installing dealer understand this

warranty. Dehumidifier Corporation of America, Inc.

applies this limited warranty on all units of its

manufacture to be free from defects in material and

workmanship under normal intended use and service

when units remain at original installation site and are

correctly installed and operated according to printed

instructions and in compliance with all local installation

and building codes and acceptable trade practices.

This Limited Warranty is void unless upon start-up

of the unit the “Start-up Report and Warranty

Registration” is completed and received at the

factory within 30 days of start-up. This will also

register the compressor warranty with the

compressor manufacturer.

The company shall, unless specified herein, during the

first three years after date of initial installation replace

any part supplied by DCA that fails because of a defect

in workmanship or material.

All controls, supplied by DCA, as part of a

dehumidification system will carry a one (1) year

warranty from date of start up as validated by the return

of the start up report returned to DCA no later than 30

days after the start up date.

All freon compressors and all other parts excluding

return air filters and blower belts, carry a three year

parts warranty. DCA will furnish a replacement

compressor, upon a compressor failure, shipped freight

collect. Subsequent compressor replacements, on a no

cost basis, will be at the discretion of DCA and will be

handled on a case by case basis. Normally after the

second compressor fails, within the 3 year warranty

period, a problem exists in the installation, maintenance

or causes beyond the control of DCA such as and not

limited to power fluctuations or lightning strikes. The

cause of failure must be determined before any action is

taken by DCA.

Refrigeration coils, as part of the DCA dehumidification

system, carry a three year warranty. DCA will furnish a

replacement refrigeration coil, upon a coil failure,

shipped freight collect. Subsequent coil replacements,

on a no cost basis, will be at the discretion of DCA and

handled on a case by case basis. Normally after the

second coil fails within the 3 year warranty period, a

problem exists in the installation, maintenance or

causes beyond the control of DCA. Premature coil fin

erosion normally signals that chemicals are stored in

the mechanical room, with the dehumidifier, or

contaminated return air is present and must be

corrected before any action is taken by DCA.

The definition of a defective dehumidifier part will be as

follows. In the case of a defective part, that falls in the

definition of its warranty period, the replacement part

will be shipped from the factory promptly with the

customer being billed immediately via COD, a valid

credit card via an existing open account with DCA. The

MODELS

DCA500 • DCA500/WH • DCA900 • DCA900/WH • DCA1400 • DCA1400/WH • DCA2000 • DCA2000/WH • DCA 2500

DCA 2500/WH • DCA 3000 • DCA 3000/WH • DCA 3300 • DCA 3300/WH • DCA 3500 • DCA 3500/WH • DCA3800 • DCA 3800/WH

DCA 4000 • DCA 4000/WH • DCA 4200 • DCA 4200/WH • DCA 5400 • DCA 5400/WH • DCA 7000 • DCA 7000/WH • DCA 8000

DCA 8000/WH • DCA 9000 • DCA 9000/WH • DCA 11000 • DCA 11000/WH • DCA 14000 • DCA 14000/WH

O W N E R ’ S   M A N U A L

Summary of Contents for DCA500

Page 1: ...I N S T A L L A T I O N O P E R A T I O N M A I N T E N A N C E SWIMMING POOL DEHUMIDIFIER OWNER S MANUAL...

Page 2: ...ing Of Remote Condenser And Charging Instructions 7 Air Flow Balancing 8 9 Unit Start Up Procedure 10 Maintenance And Service Procedure 10 Pool Water Heating Dehumidifier Procedure 11 Pool Chemical St...

Page 3: ...air The heat recovered by the above mentioned process known as latent heat and the electrical consumption of the compressor is delivered by the reheat condenser coil The air leaving the evaporator coi...

Page 4: ...ool an approved drain must be provided for proper disposal If codes permit schedule 40 PVC pipe is recommended for drainage pipe Slope the condensate drain line with a minimum of 1 4 inch per foot A P...

Page 5: ...te controls in a room that is not being conditioned by the dehumidification system unless system has remote sensors optional Controls should be mounted 5 feet from floor level on an interior wall All...

Page 6: ...air does not short cycle back to the return inlet If dehumidifier is installed without return air duct provide a minimum of 4 feel clearance between unit and closest obstruction 3 The recommended duct...

Page 7: ...Or Less 20 Or Less Discharge Discharge 5W Or More For Static Pressure Regain Intake TYPICAL DUCTED POOL ROOM INSTALLATION SMACNA DUCT DESIGNS DCA Dehumidifier Recommended Recommended Recommended Recom...

Page 8: ...re that all solder joints are clean oil free and absent of any foreign material Insert copper into valve until line bottoms out in valve Complete soldering process Pressurize line set to determine if...

Page 9: ...g Port Locations Return A L LO B HI CHART A Shows the location of the air balancing access ports and where to insert the HI and LO pressure tubes of the monometer or gauge Measure the pressure differe...

Page 10: ...ed Under no circumstances should the unit be run for temporary heat when building construction is in progress or when there is no water in the pool HUMIDISTAT This control turns the unit on or off whe...

Page 11: ...at to normal settings Typically between 50 RH and 60 RH and 82 F to 88 F MAINTENANCE AND SERVICE PROCEDURE Your DCA Dehumidifier requires minimal maintenance The following areas should be checked as r...

Page 12: ...f the dehumidifier FAILURE TO FOLLOW THE ABOVE RECOMMENDATIONS WILL RESULT IN THE VOIDING OF ALL WARRANTIES FROM DCA THAT WERE EITHER EXPRESSED IMPLIED OR WRITTEN STORAGE OF POOL OR SPA WATER CHEMICAL...

Page 13: ...Others A Air Filter B Damper Control and Timer C Outside Air Pre Heater D Bird Screen Termination 8 Mounting feet and vibratiobn isolators by others 9 Electric Gas Hot Water Add On Duct Heater By Othe...

Page 14: ...witch in in off position automatic position Unit does not shut off Malfunctioning controls Call service technician to repair or replace control Unit not operating properly Humidistat turned off Turn h...

Page 15: ...capacitor transformer or compressor Dehumidifying coil iced up Return air below 45 F Raise return air temperature Filters dirty or clogged Replace filters Low air flow Check blower motor and belt Adju...

Page 16: ...Change blower rotation 3 phase only Motor going off on internal Check for rated AMP draw overload Replace motor if defective Dirty filters Replace filters Supplyandreturnairregisters Remove restrictio...

Page 17: ...y filters Replace filters High humidity in space Incorrect duct work Check duct work design See manual Low air flow Adjust blower Check blower motor and pulley Dirty filters Replace filters Outdoor co...

Page 18: ...be at the discretion of DCA and will be handled on a case by case basis Normally after the second compressor fails within the 3 year warranty period a problem exists in the installation maintenance o...

Page 19: ...nusual use of supplemental heat 7 Actions or negligence of the installer or servicer of the unit that result in losses or damage of any kind including those due to inadequate A Sizing of the unit to t...

Page 20: ...low if required must be established 6 Duct work including duct grills and diffusers must be completed 7 A thorough leak check should be performed Due to the fact that the unit may be damaged while in...

Page 21: ...Giuffre PE Engineering 262 377 7501 tgiuffre dehumidifiercorp com Graham Gelhaar Service 262 377 7501 ggelhaar dehumidifiercorp com Jim Metzger Sales 262 377 7501 jmetzger dehumidifiercorp com Fax 26...

Reviews: