Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
Do not install the unit near the door way.
There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet and affect
its appearance. If unavoidable, sunlight prevention should be taken into consideration.
( wall or obstacle )
4cm
(min)
>30(cm)
(min)
50cm(min)
50cm(min)
Front
>200cm
Rear
5cm
(min)
(1) Please stand the unit in hard and flat ground;
Please reserve space for installation and maintenance.
(1) Before installing the outdoor unit, you should:
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
Select a place that is easy to connect indoor unit's pipe and electric wires.
Avoid a place where combustible gas may leak or stay.
Pay attention that water may drain out of the outdoor unit while in "Heat" mode.
Ensure the enough space around the back and sides and the front of the unit.
Take the air conditioner weight into account and select a place where noise and vibration are
minimum.
.
.
.
...
( Ceiling)
The outdoor unit should be put in a position that guarantees the minimum space for sufficient air
circulation and to allow maintenance work and the connections of electrical and refrigerant circuit lines.
It may be installed on a floor or flat roof or wall-mounted, provided its weight is properly supported and
there is no transmission of vibration to the adjacent rooms.
Selecting installation place
INSTALLATION INSTRUCTIONS
(2) Please check the elevation difference between the indoor unit and the outdoor unit, the length of the
refrigerant pipe, and the curved places (bend) of the pipe are no more than the following numbers:
Elevation difference:
no more than 10 M (if the elevation difference between indoor and outdoor unit
is more than 10 meters, it is recommended that the outdoor unit be located
higher than the indoor unit.)
Pipe length:
no more than 20 M
Bends:
no more than 5 places
Summary of Contents for XQS140UY1
Page 1: ...Kullanım Kılavuzu Salon Tipi Split Klima İç Ünite XVQ140UY1 Dış Ünite XQS140UY1 ...
Page 18: ...Kumanda Kılavuzu Salon Tipi Split Klima İç Ünite Dış Ünite XVQ140UY1 XQS140UY1 ...
Page 33: ...Montaj Kılavuzu Salon Tipi Split Klima İç Ünite Dış Ünite XVQ140UY1 XQS140UY1 ...
Page 53: ...User Manual Floor Standing Type Air Conditioner Indoor Unit Outdoor Unit XVQ140UY1 XQS140UY1 ...