7
Pipe/wire-hole position on back side
Ship the air conditioner to the installation place originally packed;
Be careful while hanging the unit because the center of gravity of the unit is not centralized;
Do not make the angle of inclination more than 45 degrees while shipping;(Avoid horizontal
storage)
Be sure the electric insulation work is well done if installed on metal ceiling / wall.
Fix the unit feet with bolts (M10/M8). Be sure the unit is fixed strongly enough to against blast
or earthquake.
Make a concrete basement to the unit by the above references.
Pipe/wire-hole position on the bottom
Wiring
Hole
φ
35
2 Outdoor Unit
The refrigerant pipe and the drain pipe should be heat-insulated to avoid condensing and
water-dropping.
A reamer joint is adopted to connect the indoor unit with the outdoor unit.
The refrigerant pipe is used to connect indoor and outdoor units, showed as below.
The pipe can not be curved for more than 3 times.
Cover all exposed reamer joint pipes and refrigerant
pipes with heat-insulation material.
NOTE
Refrigerant Pipe Connection
Polythene pipe
Heat-insulation cover
Bendable
Reamer Joint
Outdoor
Unit
PIPE CONNECTION
A
B
Air inlet
Air outlet
Air inlet
Refrigerant/drain
Pipe hole
φ
85
Refrigerant/drain
Pipe hole
φ
85
Outdoor unit dimension
mm(WxHxD)
A(mm)
560
590
B(mm)
335
333
623
590
366
378
602
380
Mounting dimensions
845x700x320
900x860x315
940x1245x360
990x965x345
900x1170x350
Summary of Contents for XQS140UY1
Page 1: ...Kullanım Kılavuzu Salon Tipi Split Klima İç Ünite XVQ140UY1 Dış Ünite XQS140UY1 ...
Page 18: ...Kumanda Kılavuzu Salon Tipi Split Klima İç Ünite Dış Ünite XVQ140UY1 XQS140UY1 ...
Page 33: ...Montaj Kılavuzu Salon Tipi Split Klima İç Ünite Dış Ünite XVQ140UY1 XQS140UY1 ...
Page 53: ...User Manual Floor Standing Type Air Conditioner Indoor Unit Outdoor Unit XVQ140UY1 XQS140UY1 ...