background image

14

Do not use strong acids or high concentrations as these may 
attack  and  destroy  the  element  or  other  metal  parts  of  the 
boiler.

NOTE

Set

Clean

1.  To start the process press the “       “ key for 5 seconds, “Clean” LED light will come on 

and time window display last setting time (default setting is 8 hours). 

2.  Press “     “ or “     “ for 5 seconds, to change display into hours, increase or decrease 

to set the required time, each button press will increase or decrease 1 hour, maximum 
is 24 hours, minimum is 1 hour. 

3.  Once the setting is done the flashing will stop and the process will begin automatically 

by opening, the inlet valve for the boiler to fill with the descaling solution. The inlet 
valve will then close and the solution will remain inside the boiler for the preset time.

5.3 Descaling Process

5.4 Flushing and Draining

1.  At the end of the sequence, the drain valve will open and the boiler will drain and then 

flush with clean water; when the cycle is complete the drain LED will go off.

2.  Ensure there is sufficient descaling solution in the container to completely fill the boiler 

- when liquid level reaches set point , the LED on circuit board will light up.

If  during  descaling  the  power  supply  is  interrupted  do  not 
operate the steam generator until either the descaling process 
has been reset or the acid solution has been drained and the 
boiler ushed with clean water – minimum 3 ushes.

CAUTION

6. TROUBLE SHOOTING 

Fault

1.  Check power supply voltage.
2.  If  Indicator  LED  of  power  supply  on 

circuit  board  is  not  in  red  then  check  
transformer.  

3. If the LED is red, remove controller, use  

circuit  board  and  turn  the  steam 
generator  If  steam  generator  doesn’t 
work .then circuit board is faulty, change 
circuit board.

4. If the circuit board is ok and the steam 

generator  works  normally,  Check  the 
control cable port and controller. 

Cause

Solution

1. No Power Supply
2. Transformer faulty
3.Main  Circuit  Board 

faulty

4. Control Cable or Port
faulty

There  is  no 
display on the 
control  panel 
w h e n   t h e 
on/off  switch 
is pressed 

Summary of Contents for DSTEAM90

Page 1: ...Steam Generator STEAM GENERATOR...

Page 2: ......

Page 3: ...10 4 1 Steam Room Design 7 6 TROUBLE SHOOTING 14 8 TERMS OF WARRANTY 17 Davis Shirtliff Ltd 2022 Contents herein are not warranted 5 OPERATION 12 7 MAINTENANCE 16 5 2 Setting Time Temperature 13 5 3...

Page 4: ...g a steam head and auto drain valve Provision for auto descaling is provided OPERATING CONDITIONS Water Pressure Min 0 25Bar Max 8Bar Water Quality Hardness less than 50ppm CaCo above which regular de...

Page 5: ...where both the electrical power and water supply can be isolated in an emergency WARNING The minimum water inlet pressure is 0 25 bar and a maximum of 8 bar working pressure should not exceed 5 bar W...

Page 6: ...led on level ground WARNING The Steam generator should not be in close proximity to hazardous substances WARNING The size of heater required to heat a particular size of steam room is dependent on typ...

Page 7: ...Insulation Material 7 Detect the water level Water Level Probe 8 Steam Outlet Steam Outlet 9 13 Operates if the pressure in the boiler exceeds 10 2bar 10 11 12 Pressure Relief Valve 0 To protect boile...

Page 8: ...lly when not steaming On Off On Off Light Light Temperature Display Time Display Push to operate lights Drain Drain Fan Mode Mode Enter 4 Dual function button used when steaming to set the time temper...

Page 9: ...Drain LED 13 Operation mode indicator red is for steam on demand mode and green for conventional timing Mode LED 14 Green indicates heating is on red indicates the required temperature Heating LED 15...

Page 10: ...W will heat up to 3 1m of air For dense materials such as stones and ceramics which conduct heat more 3 rapidly allow for up to 2kW per m of air Hot air rises so restricting the height to around 2 met...

Page 11: ...e included in the controller to set working times in regular intervals of 30minutes The steam generator should be installed in a dry well ventilated place in close proximity to the steam room It can b...

Page 12: ...fort it s h o u l d b e a t t h e farthest place from the seat STEAM GENERATOR Valve Water Level Probe Overheat Switch According to the location it may be necessary to attach an additional length of p...

Page 13: ...am room at approximately 1 2 to 1 5 meters high and away from the door respective Use a 4mm screw to fix it in place and connect to the wire from the controller 10 Temperature Sensor 4 Screw Installat...

Page 14: ...Fig 10 11 9kW Steam Generator Circuit Diagram 12 15kW Steam Generator Circuit Diagram Fig 11...

Page 15: ...the water inlet valve will turn off 3 After a few minutes of operation the generator will begin steaming for small steam generator 2 3 minutes and about 3 5 minutes for larger generators 4 Press the k...

Page 16: ...altering the settings of the JP1 pins on the circuit board Fan Enter Set Clean 5 2 Setting Time and Temperature 0 The steam generator default settings are 40 C temp and 1 hour of operation which can b...

Page 17: ...with clean water when the cycle is complete the drain LED will go off 2 Ensure there is sufficient descaling solution in the container to completely fill the boiler when liquid level reaches set poin...

Page 18: ...here is no steam being produced 1 Replace main circuit board 2 Replace relay circuit board 3 Replace heating elements 1 Main Circuit Board Faulty 2 Relay Circuit Board Faulty 3 Heating Elements Faulty...

Page 19: ...sulting in leaks from around the elements The extent of the problem will vary according to the degree of hardness in the local water supply It is recommended to use water softener NOTE All commercial...

Page 20: ...ranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by replace...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...INS498A 04 22...