Commercial Mode Instruction (OC-B+OC-S )
If OC-B is under domestic model, only the OC-B controls the steam generator .OC-S will
not work. When OC-B is used on commercial model, the steam generator will be under
waiting status (the time window shows “Long” and on circuit board the LED will be
flashing) , press OC-S to operate steam generator , every press will make the steam
generator keep working for intervals of 30 minutes , the temperature control will depend
on the OC-B controller’s setting.
4. INSTALLATION
7
4.1 Steam Room Design
As a guide; For lightweight materials such as plastics and laminates, 1 kW will heat up to
3
1m of air. For dense materials such as stones and ceramics which conduct heat more
3
rapidly allow for up to 2kW per m of air. Hot air rises so restricting the height to around 2
meters will ensure the user is sitting in the steam. For higher ceilings, ensure to increase
the power requirement.
If greater power is required one OC-B controller may be used to control two or more
steam generators, e.g. if a 30kW steam generator is needed, one OC-B controller can
control two 15kW steam generator or three 10 kW steam generators .
Fig 1: Schematic Layout Multiple Generator
Temperature Sensor
Master
OC-B Controller
To Next Slave
Slave 1
Slave 2
Temperature
Sensor
OC-B Controller
Fig 2: Schematic Wiring of Multiple Generators
Master
Slave 1
To Slave
Slave 2
To Next Slave
From Master