Fig 7: Minimum Setting Dimensions
1. The water supply pipe and steam pipe should comply with local standards.
2. Connect the water inlet valve of the generator to the 15mm mains water supply using
a flexible hose with 1/2 inch fittings.
3. Steam outlet (1/2 inch or 3/4 inch) should use the same dimension copper pipe for
ease of connection
4.3 Water & Steam Connection
Fig 8: Accessory Installation Layout
T h e s t e a m n o z z l e
s h o u l d b e 3 0 0 m m
away from the ground .
For user comfort it
s h o u l d b e a t t h e
farthest place from the
seat.
STEAM GENERATOR
Valve
Water Level Probe
Overheat Switch
According to the location it may be necessary to attach an
additional length of pipe to the pressure relief valve in order to
divert the steam ow to a safe direction should the valve
operate.
NOTE
9
315mm - 9/12kW
215mm
415mm - 15kW
215mm
Ÿ
To hang the generator on a wall drill 3 holes 8mm in diameter as below image and
use the wall plugs and screws provided.
Ÿ
Fix the top 2 screws in place first then hang the generator by the 2 keyhole shaped
holes in the back plate.
Ÿ
Then with the front cover removed fix the third screw to secure the unit in place.