4096-225
3.4M & 3.7M Az/El TRUSS MOUNT
22
Ku-BAND FEED
DUAL POL - Coat the o-ring (item #6) with the silicone grease from the capsule
provided and place it in the feed horn o-ring groove. Attach the OMT (item #1) to the
feed horn (item #2) with the #6 hardware (item #'s 3,4,& 5). Attach two LNB's (customer
provided) to the OMT with the o-rings and hardware provided with the LNB's. See figure
2. Tighten securely.
Ku-BAND - DUAL POL - PARTS LIST
ITEM #
PART #
DESCRIPTION
QUANTITY
1
0183-272
OMT, Ku-BAND - DUAL - RECEIVE
1
2
0183-276
FEED HORN ASSEMBLY
1
3
8300-012
#6-32 x .75 S.S. STD. SCREW
6
4
8200-010
#6 LOCKWASHER
6
5
8112-001
#6-32 S.S. STD. HEX NUT
6
6
0198-120
O-RING
1
[ 5 ]
[ 4 ]
[ 2 ]
[ 6 ]
[ 1 ]
[ 3 ]
CUSTOMER PROVIDED LNB
FIGURE 2.
DAWNco • 3340 S. Lapeer Rd • Orion, MI 48359-1320 • Ph (248) 391-9200 • Fax (248) 391-9207 • [email protected]