1300 790 890
www.davidgolf.com.au
18
PROBLEM
There is a green LED on GFI
switch but there is no power
at power supply 12vdc
PROBABLE CAUSE
Power supply disconnected
from GFI.
Defective power supply.
Obstruction in hopper
preventing range balls from
entering drop mechanism.
Obstruction holding drop
mechanism in open position.
REMEDY
Reconnect power supply.
Replace power supply.
Remove obstruction.
Remove obstruction.
Actuator motor not working.
There is an LED on the control
board but actuator doesn’t
work
There is no power present at
black connector located on the
actuator motor.
Defective actuator motor
NO power at the control board
Defective control board
Plug is disconnected from
actuator
Check for power at the actua-
tor, it should read 12vdc at the
connector at all times.
Depress GFI reset button LED
on GFI
On top right corner should be
green if power is present.
Replaced actuator
Check for power in from power
supply.12vdc
Replaced control board
Reconnect plug
Summary of Contents for Easy Picker BALL DISPENSER
Page 15: ...1300 790 890 www davidgolf com au 15 FIGURE 10 WIRING 120 VAC TO 12 VDC 2010 TO PRESENT ...
Page 16: ...1300 790 890 www davidgolf com au 16 FIGURE 11 WIRING HARNESS 2010 TO PRESENT ...
Page 22: ...1300 790 890 www davidgolf com au 22 ...