19537P-26 (11-14)
12 of 15
4. Power Cable
The C98-20PW is a 20-foot cable used to provide power to the M-RIM. It has a connector on one end
and is unterminated on the other end. It is important to choose a power “pick
-
off” point that can provide at
least two amperes of current at a voltage between 11-30VDC. Direct connection to a 2-Amp fuse/circuit-
breaker is preferred.
Parts/Tools Required
q
C98-20PW Power Cable (40892G-02)
o
Includes David Clark 2-Amp Fuse kit (40688G-47)
q
Power pick-off point (circuit breaker/Fuse box, 11-30VDC)
q
Soldering iron/Solder
q
Wire terminals
q
Wire cutters/ Wire strippers
q
Tape Measure
q
Wire ties
Figure 6: C98-20PW Cable with 40688G-47 2-Amp Fuse kit
Procedure
q
Determine the location of a 2-Amp circuit breaker to be used and how to connect to it (solder,
screw terminals, lugs, etc).
q
If only a higher-amperage circuit breaker is available, it may be used, but the David Clark 2-Amp
Fuse Kit must also be used.
q
Determine the location of the 11-30VDC and Ground pick-off points.
q
Determine the path of the cable between the power source and the M-RIM. The cable should be
routed using under-deck conduits and be as far as possible from radio antenna coax cables and
anywhere water may collect.
q
Measure the length of cable necessary, adding 3 ft as a service loop.
q
If necessary, trim the length of the cable to the length you just determined in the previous step.
Be sure to trim the UN-PREPARED end of the cable.
q
Route the cable. Use wire ties where necessary.