19537P-26 (11-14)
A1
Appendix A
P/N 40688G-47 Waterproof Fuse Kit
Installation Instructions
Parts/Tools Required
·
1/8-inch diameter heat shrink tubing
·
Wire strippers
·
Crimp tool (Radio Shack P/N 64-409 or equivalent)
·
Crimp terminals
·
2-Amp fuse kit
Procedure
1. Using a heat gun, install 1/8" diameter heat shrink tubing* over one end of the 4" red wire
(supplied). Install the second piece of 1/8" diameter heat shrink tubing over the red wire on
the C98-20PW Power Cable.
2. Thread red wire of power cord with heat shrink tubing* into one end of fuse holder.
3. Thread the heat shrink end of the 4-inch red wire into other end of fuse holder.
4. Strip insulation on both wires 1/4 inch.
5. Crimp fuse clips to both wires. (Recommended crimp tool Radio Shack No. 64-409 or
equivalent).
6. Insert 2-amp fuse.
7.
Snap two halves of housing together.
Figure A1: Proper assembly of Fuse Holder Kit (40688G-47)
* Note: The heat shrink tubing is
necessary in order to provide
weather tightness.