![Davey Steriflo UV130 Installation And Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/davey/steriflo-uv130/steriflo-uv130_installation-and-operating-instructions-manual_3861344008.webp)
8
Electrical Power Surge Protection
An electrical power surge or spike can travel on the supply lines and cause
serious damage to your electrical equipment. The Steriflo control box has a 2 Amp
fuse
to protect the circuit. The fuse is not a lightning arrestor and may not protect the
Steriflo if lightning or a very powerful surge hits the unit.
If the installation is subject to electrical power surges or lightning we strongly
recommend the use of suitable additional surge protection devices on ALL
electrical equipment.
We recommend the use of an RCD or earth leakage circuit breaker on the power
supply to your unit.
DO NOT LOOK AT UV LAMP WHILE LAMP IS
OPERATING Ultra violet radiation is harmful to
skin & eyes.
DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU
HAVE FULLY READ THESE INSTRUCTIONS!
Pipe Connections
NOTE: Prior to installation remove the transport plugs
from the inlet, outlet and lamp end cap.
Never use PVC pipe directly connected to unit. PVC pipe and fittings can be used
after 90o bends of a suitable material are connected to the inlet and outlet of the
chamber. Larger diameter pipe may be used to minimise resistance to flow, but
maximum flow rates should not be exceeded, as correct water treatment cannot
be assured at higher flows. If flows may exceed the design maximum, install a
flow restriction device.
Do not use pipe thread sealing compounds (especially
hemp) on any part of this unit. ONLY use Teflon
sealing tape.
Use unions at pipe connections to enable easy removal and servicing. Use
sufficient tape to ensure airtight seal and do not over tighten. To prevent strain on
unit threads always support heavy inlet and outlet pipes.