Care should also be taken when servicing or 
disassembling the unit and associated pipework to 
avoid possible injury from pressurised water. Unplug 

power, relieve pressure by opening a tap on the 

discharge side of the unit and allow any water in the 
unit to cool before attempting to dismantle.

Part Numbers

Model

Number 
of lamps 

GPH840N2/S

Number of 
sleeves 
QS880

Oring 

S24x3N70

Lamp 
connector 

S114/2

UV130

1

1

1

2

UV250

2

2

1

2

During service DO NOT use lubricants or sealants of 
any type on the orings. Keep the inside of the quartz 
sleeve dry and clean.

WARNING - Do not use hydrocarbon based or 
hydrocarbon propelled sprays around the electrical 
components of this unit.

After Sales Service

For professional after sales service or repair, contact your dealer.

For assistance in locating your nearest dealer, contact Davey Water Products Pty 
Ltd, customer service centre on 1300 232 839, by fax 1300 369 119 or by email 
[email protected]. In New Zealand on 0800 654 333, by fax on 0800 654 334 
or by email to [email protected] or visit davey.com.au.

Summary of Contents for Steriflo UV130

Page 1: ...Please pass these instructions on to the operator of this equipment Installation and Operating Instructions Ultra Violet Water Treatment System UV130 and UV250...

Page 2: ...to 45 C Contact your dealer for details of UV systems suitable for hot water service DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ THESE INSTRUCTIONS Maximum operating pressure for stain...

Page 3: ...nection 6 Electrical Power Surge Protection 8 Pipe Connections 8 Pre treatment drinking water 9 Lamp Installation 9 Operation 10 Maintenance 10 Water Quality 12 Lamp Alarm System 12 Trouble Shooting 1...

Page 4: ...d by the guarantee Your Ultra Violet water treatment system is designed to handle clean water The system should not be used for any other purpose without specific referral to CCL The use of the system...

Page 5: ...for access to the end nut The open end nut and the blank end nut are interchangeable so lamp removal can be from either end Housing your Steriflo System To protect your Steriflo system from the weath...

Page 6: ...trical connections should be serviced only by qualified persons If the electrical supply lead of this system is damaged it must only be replaced by a qualified service personnel Connect lead to power...

Page 7: ...talled to fixed wiring without the plug a two pole switch must be fitted and its ON and OFF positions shall be marked The Steriflo control box has a red LED alarm indicator light mounted on its front...

Page 8: ...SASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ THESE INSTRUCTIONS Pipe Connections NOTE Prior to installation remove the transport plugs from the inlet outlet and lamp end cap Never use PVC pipe d...

Page 9: ...eatment chamber check that the chamber is clean to ensure the sticker will adhere correctly The Quartz Sleeve is pre installed in the treatment chamber and provided the endcaps have not been disturbed...

Page 10: ...preferably overnight The Steritank HP or Acquasafe solution can be dosed to the water tank or if necessary added as a shot dose to the bowl of any filter housing installed with the UV system and slowl...

Page 11: ...gs 1 Remove lamp as described 2 Remove drain port cap and empty water from chamber 3 Undo nut at one end of the chamber and remove oring repeat with nut at other end and remove oring withdraw sleeve c...

Page 12: ...ill light and the alarm contacts will changeover These are able to close a normally open solenoid valve The alarm function can be checked by switching the unit off disconnecting the lamp and then swit...

Page 13: ...er supply b UV LAMP FLICKERING ALARM ON 1 Failed lamp 2 Incorrect lamp or ballast fitted c UV LAMP OUT ALARM ON 1 Lamp failed 2 Poor connection to lamp check clean connector lamp pins 3 Ballast failed...

Page 14: ...2 2 1 2 During service DO NOT use lubricants or sealants of any type on the orings Keep the inside of the quartz sleeve dry and clean WARNING Do not use hydrocarbon based or hydrocarbon propelled spra...

Page 15: ...o keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doub...

Page 16: ...eceipt as proof of purchase you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee Davey shall not be liable for any loss of profits or any consequ...

Reviews: