background image

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any 
malfunction within one year of the date of original purchase due to faulty materials or 
manufacture, Davey will at our option repair or replace it for you free of charge, subject  
to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first 

instance that you contact the Davey Dealer from which you purchased the Davey product. 
Alternatively you can phone our Customer Service line on 1300 232 839 in Australia,  
or 0800 654 333 in New Zealand, or send a written letter to Davey at the address listed 

below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product 

is faulty or defective, advise you on how to have your Davey product repaired, obtain a 
replacement or a refund.

Your Davey One Year Guarantee naturally does not cover normal wear or tear, replacement 
of product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage 
resulting from misuse or negligent handling, improper use for which the product was not 
designed or advertised, failure to properly follow the provided installation and operating 
instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, 
lightning or high voltage spikes, or unauthorized persons attempting repairs. Where 
applicable, your Davey product must only be connected to the voltage shown on the 
nameplate.

Your Davey One Year Guarantee does not cover freight or any other costs incurred in making 
a claim. Please retain your receipt as proof of purchase; you MUST provide evidence of the 
date of original purchase when claiming under the Davey One Year Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, 

damage or injury of any kind whatsoever arising directly or indirectly from Davey products. 
This limitation does not apply to any liability of Davey for failure to comply with a consumer 
guarantee applicable to your Davey product under the Australian or New Zealand legislation 
and does not affect any rights or remedies that may be available to you under the Australian 
or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for 
compensation for any other reasonably foreseeable loss or damage. You are also entitled 
to have the goods repaired or replaced if the goods fail to be of acceptable quality and the 
failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your 
nearest Davey Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

AUSTRALIA

Customer Service Centre

6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 

1300 232 839

Fax: 

1300 369 119

Website: davey.com.au
Email: [email protected]

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND

Customer Service Centre

7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 

0800 654 333

Fax: 

0800 654 334

Website: daveynz.co.nz
Email: [email protected]

® Davey is a registered trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2015.

* Installation and operating instructions are included with the product when purchased new. 

They may also be found at davey.com.au

Summary of Contents for Steriflo UV130

Page 1: ...Please pass these instructions on to the operator of this equipment Installation and Operating Instructions Ultra Violet Water Treatment System UV130 and UV250...

Page 2: ...to 45 C Contact your dealer for details of UV systems suitable for hot water service DO NOT DISASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ THESE INSTRUCTIONS Maximum operating pressure for stain...

Page 3: ...nection 6 Electrical Power Surge Protection 8 Pipe Connections 8 Pre treatment drinking water 9 Lamp Installation 9 Operation 10 Maintenance 10 Water Quality 12 Lamp Alarm System 12 Trouble Shooting 1...

Page 4: ...d by the guarantee Your Ultra Violet water treatment system is designed to handle clean water The system should not be used for any other purpose without specific referral to CCL The use of the system...

Page 5: ...for access to the end nut The open end nut and the blank end nut are interchangeable so lamp removal can be from either end Housing your Steriflo System To protect your Steriflo system from the weath...

Page 6: ...trical connections should be serviced only by qualified persons If the electrical supply lead of this system is damaged it must only be replaced by a qualified service personnel Connect lead to power...

Page 7: ...talled to fixed wiring without the plug a two pole switch must be fitted and its ON and OFF positions shall be marked The Steriflo control box has a red LED alarm indicator light mounted on its front...

Page 8: ...SASSEMBLE ANY COMPONENTS UNTIL YOU HAVE FULLY READ THESE INSTRUCTIONS Pipe Connections NOTE Prior to installation remove the transport plugs from the inlet outlet and lamp end cap Never use PVC pipe d...

Page 9: ...eatment chamber check that the chamber is clean to ensure the sticker will adhere correctly The Quartz Sleeve is pre installed in the treatment chamber and provided the endcaps have not been disturbed...

Page 10: ...preferably overnight The Steritank HP or Acquasafe solution can be dosed to the water tank or if necessary added as a shot dose to the bowl of any filter housing installed with the UV system and slowl...

Page 11: ...gs 1 Remove lamp as described 2 Remove drain port cap and empty water from chamber 3 Undo nut at one end of the chamber and remove oring repeat with nut at other end and remove oring withdraw sleeve c...

Page 12: ...ill light and the alarm contacts will changeover These are able to close a normally open solenoid valve The alarm function can be checked by switching the unit off disconnecting the lamp and then swit...

Page 13: ...er supply b UV LAMP FLICKERING ALARM ON 1 Failed lamp 2 Incorrect lamp or ballast fitted c UV LAMP OUT ALARM ON 1 Lamp failed 2 Poor connection to lamp check clean connector lamp pins 3 Ballast failed...

Page 14: ...2 2 1 2 During service DO NOT use lubricants or sealants of any type on the orings Keep the inside of the quartz sleeve dry and clean WARNING Do not use hydrocarbon based or hydrocarbon propelled spra...

Page 15: ...o keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doub...

Page 16: ...eceipt as proof of purchase you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee Davey shall not be liable for any loss of profits or any consequ...

Reviews: