Low Energy Operation:
Your ProMaster
TM
VSD Eco-Series pump has speed settings from
1500 to 3600 RPM:
- 1500 – Lowest Speed, 1
- 3600 – Highest Speed, 10
- 3800 – Backwash Speed
• Speed 1 provides the lowest speed and therefore the greatest energy
efficiency and savings. See page 9 for all other dial position speeds.
Operation
Recommended Speed Setting
Pool Filtration
Speed 1 to 4
Suction pool cleaner operation
Speed 5 to 8
Backwashing your media filter
Backwash Speed
Manually cleaning your pool
Speed 9 to 10
Water Feature operation
Spa Jet operation
Solar pool heating
Guidelines for Recommended Pump Operating Hours:
Australian Standards AS3633: “Private swimming pools - water quality”
states that “The minimum turnover rate shall be a single turnover of the full
volume of the pool water, within the period that the pump would normally be
operating….”
The table below provides a guide only to the running times of your pump
while in filtration mode in order to achieve the minimum turn over rate:
Pool Size
(Litres)
Speed Setting (hours)
Speed 1
Speed 5
Speed 10
20,000
3.3
1.7
1.1
30,000
5.0
2.5
1.7
40,000
6.7
3.3
2.2
50,000
8.3
4.2
2.8
60,000
10.0
5.0
3.3
80,000
13.3
6.7
4.4
100,000
16.7
8.3
5.6
8
NOTE:
Whenever you increase the pump run time, you should decrease
the chlorine output of your chlorinator to avoid the risk of over chlorination.