12

Trouble Shooting

If the pump runs but there is no water flow or water flow is reduced,
the following condition may apply:

1.  The filter requires backwashing or it is blocked. Refer to the relevant 

section in the Filter Manual.

2.  The pump is not primed. Re-prime as per instruction in ‘Starting the pump’
3.  There are air leaks in the suction piping. Check all piping and eliminate 

leaks, also check for a loose strainer basket lid. Air bubbles in the water 
flowing back to the pool would indicate a leak in the suction to the pump 
allowing air to enter the pipework.

4.  A leaking pump shaft seal may also prevent operation. Evidence of this 

would be water on the ground under the pump.

5.  The pump is not able to get water from the pool. Check that the valves to 

the pump are fully open and that the pool water level is up to the skimmer 
box.

6.  Blockage in the piping or pump. Remove the strainer basket and check 

for any blockage to the pump impeller entry. Check the skimmer box for 
blockage.

If the pump does not operate, the following conditions may apply:

1.  The power is not connected. For 240 volt only, check the power point by 

plugging in a portable appliance to ensure power is available. Also check 
fuses and the main power supply switch

2.  Automatic overload is tripped. The pump has an in-built thermal overload 

which will re-set automatically after the motor has cooled following an 
overheating period. Determine the cause of the overload tripping and 
rectify. Re-set the pump by switching the power OFF for 30 seconds.

3.  Blockage is preventing the pump from rotating.
4.  Motor is burnt out - burning smell is evident. Replacement is required. 

If you are unable to resolve any installation or operation difficulties 
with your ProMaster

, contact the supplier from whom the pump was 

purchased or your nearest Authorised Davey Pool Equipment Service 
Centre. If any further assistance is required, contact the Davey Customer 
Service Centre at the address indicated in this manual.

LED Signal & Function

LED Signal

  

Function

ON  

Pump is running

OFF  

Pump is off

Slow Flash (Pump Running) 

Priming or Bachwash

Fast Flash (Pump Stopped) 

Fault detected - reset pump

Summary of Contents for ProMaster VSD ECO Series

Page 1: ...es may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installat...

Page 2: ...ly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performan...

Page 3: ...his is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduc...

Page 4: ...Motor Input Power W hp Speed Setting 1 116W 0 16 hp Speed Setting 5 488W 0 65 hp Speed Setting 10 1000W 1 34 hp Backwash Setting 1316W 1 76 hp Operating Limits Max Water temperature 40 C Max Ambient...

Page 5: ...240 volt 50 60Hz power supply and are equipped with a flex and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided...

Page 6: ...ivalent If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool Th...

Page 7: ...ould be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required Prior to us...

Page 8: ...elines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the...

Page 9: ...your pool and refer to the pressure indicated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation 0...

Page 10: ...o 10 A Davey Frill NeckWIZARD suction pool cleaner is recommended to run between speeds 3 to 6 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When...

Page 11: ...ge rubber o ring Firm hand tightness only is required The o ring thread can be lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered b...

Page 12: ...ox for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 240 volt only check the power point by plugging in a portable appliance to ensure power...

Page 13: ...the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterTM be certain to quote the model number from the...

Page 14: ...mer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are...

Page 15: ...he Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from Davey pro...

Page 16: ...ope 2 Rue A Fresnel 69680 Chaissie France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email export davey com au Website daveyeurope eu DAVEY INTERNATIONAL Australian Head Office Ph 613 9730 9124 Fax...

Reviews: