background image

5

Installation of the ProMaster

TM

 VSD Eco-Series Pump:

Location

The pump should be located as close to the water as practicable and mounted 
on a firm base in a well drained position, high enough to prevent any flooding. It is 
the installer’s/owner’s responsibility to locate the pump such that the nameplate 
can be easily read and the pump can be readily accessed for service.

Weather Protection

It is recommended that the pump is protected from the weather. Enclosures 
should be ventilated to prevent condensation build-up.

Power Connection

Davey ProMaster

TM

 is suitable for connection to a nominal 220/240 volt 50/60Hz 

power supply and are equipped with a flex and 3 pin plug. If a power outlet is not 
available within 3 metres of the pump, a 3 pin power point in a safe, dry place 
may need to be provided by an electrician. Extension cords are unsafe around 
pools - and should be avoided. If the supply cord of this product is damaged it 
must be replaced by the dealer or manufacturer, with genuine Davey spares.

This ProMaster

TM

 pool pump incorporates motor overload detection designed to 

protect the motor from overheating. If the motor gets too hot during operation, it’s 
operating speed will reduce to bring it within a acceptable operating temperature 
and then will speed up to the originally set speed.

To reset the motor, switch the power off for 30 seconds, and then return the 
power from the mains switch.

Summary of Contents for ProMaster VSD ECO Series

Page 1: ...es may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installat...

Page 2: ...ly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performan...

Page 3: ...his is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduc...

Page 4: ...Motor Input Power W hp Speed Setting 1 116W 0 16 hp Speed Setting 5 488W 0 65 hp Speed Setting 10 1000W 1 34 hp Backwash Setting 1316W 1 76 hp Operating Limits Max Water temperature 40 C Max Ambient...

Page 5: ...240 volt 50 60Hz power supply and are equipped with a flex and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided...

Page 6: ...ivalent If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool Th...

Page 7: ...ould be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required Prior to us...

Page 8: ...elines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the...

Page 9: ...your pool and refer to the pressure indicated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation 0...

Page 10: ...o 10 A Davey Frill NeckWIZARD suction pool cleaner is recommended to run between speeds 3 to 6 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When...

Page 11: ...ge rubber o ring Firm hand tightness only is required The o ring thread can be lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered b...

Page 12: ...ox for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 240 volt only check the power point by plugging in a portable appliance to ensure power...

Page 13: ...the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterTM be certain to quote the model number from the...

Page 14: ...mer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are...

Page 15: ...he Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from Davey pro...

Page 16: ...ope 2 Rue A Fresnel 69680 Chaissie France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email export davey com au Website daveyeurope eu DAVEY INTERNATIONAL Australian Head Office Ph 613 9730 9124 Fax...

Reviews: