background image

AUSTRALIA
Head Offi ce

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

   0800 654 333

Fax:     0800 654 334

Website: daveynz.co.nz

EUROPE

Monarch Pool Systems Europe

2 Rue A. Fresnel,

69680 Chaissie - France

Ph: 

+33 (0) 4 72 13 95 07

Fax: 

+33 (0) 4 72 33 64 57

Email: [email protected]

Website: daveyeurope.eu

DAVEY INTERNATIONAL
Australian Head Offi ce

Ph: 

+613 9730 9124

Fax: 

+613 9753 4248

Email: [email protected]

Website: davey.com.au

™ Davey is a trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2015.

NORTH AMERICA

Florida USA 

Ph: 

866 328 7867

Email: [email protected]

Website: daveypoolusa.com

MIDDLE EAST

Ph: 

+971 50 6368764

Fax: 

+971 6 5730472

Email: [email protected]

P/N 402440-3

Summary of Contents for ProMaster VSD ECO Series

Page 1: ...es may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installat...

Page 2: ...ly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performan...

Page 3: ...his is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduc...

Page 4: ...Motor Input Power W hp Speed Setting 1 116W 0 16 hp Speed Setting 5 488W 0 65 hp Speed Setting 10 1000W 1 34 hp Backwash Setting 1316W 1 76 hp Operating Limits Max Water temperature 40 C Max Ambient...

Page 5: ...240 volt 50 60Hz power supply and are equipped with a flex and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided...

Page 6: ...ivalent If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool Th...

Page 7: ...ould be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required Prior to us...

Page 8: ...elines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the...

Page 9: ...your pool and refer to the pressure indicated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation 0...

Page 10: ...o 10 A Davey Frill NeckWIZARD suction pool cleaner is recommended to run between speeds 3 to 6 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When...

Page 11: ...ge rubber o ring Firm hand tightness only is required The o ring thread can be lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered b...

Page 12: ...ox for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 240 volt only check the power point by plugging in a portable appliance to ensure power...

Page 13: ...the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterTM be certain to quote the model number from the...

Page 14: ...mer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are...

Page 15: ...he Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from Davey pro...

Page 16: ...ope 2 Rue A Fresnel 69680 Chaissie France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email export davey com au Website daveyeurope eu DAVEY INTERNATIONAL Australian Head Office Ph 613 9730 9124 Fax...