![Datamax H Class Operator'S Manual Download Page 79](http://html.mh-extra.com/html/datamax/h-class/h-class_operators-manual_512784079.webp)
71
OPTION
FEEDBACK
Allows feedback characters from an optional device to be returned to the
host device, in the format of:
<A;B;C;D;E;F>[CR]
Where:
A
-
Is the device type: R = RFID; and, S = Linear Scanner
B
-
Is the resulting status: C = entire label complete; F = faulted
(failed) label; and, U = unknown
C
-
Is the number of expected reads for bar codes or tags, given in
two characters.
D
-
Is the number of good reads for bar codes or tags, given in two
characters.
E
-
Is the printer’s internal Job and Sub Job Identifier, given in four
characters each.
F
-
Is the data that was read, delimited with semicolons (;) on
multiple reads.
DISABLED
Normal printer operating mode; no data is reported. (Default Setting)
SCANNER
Linear Scanner information is reported.
RFID HEX
RFID information is reported in hexadecimal format.
RFID ASCII
RFID information is reported in an ASCII format.
PROCESS SOH
(DATA)
Determines the way the printer responds to an Immediate Command
(e.g., Get Status, Request Memory Module Storage Information, etc.).
ENABLED
Upon receipt, operations are interrupted to process that command.
DISABLED
Normal printer operating mode. (Default Setting)