97
Step
Action
Displayed
Message
Comment(s)
8
Use the UP, DOWN, LEFT, and
RIGHT Buttons to set the Gain
Number to 00 and then press the
ENTER Key.
Record the reading as a TOF
Value for Gain Number 00 in the
table.
Increment the Gain Number and
press the ENTER Key, note the
TOF Value. Repeat this process to
document the TOF Values for the
thirty remaining Gain Numbers.
Calibration Table
Gain
Number
Label
Value
TOF
Value
Difference
Value
00 252
248
01 250
245
02 248
234
... ...
...
31 131
14
TRAN SENSOR
GAIN
(0 -
31)
YYY
0
0
Note:
The LEFT and RIGHT Buttons
shift the cursor position.
9
In the table, where both the Label
Value and TOF Value are above
20, subtract them and record the
result as a Difference Value (see
below). Then find the largest
Difference Value in your table – its
corresponding Gain Number will be
used for sampling the media.
Calibration Table
Gain
Number
Label
Value
TOF
Value
Difference
Value
00 252
248 4
01 250
245 5
... ...
... ...
06 200
88 112
07 189
58 131
08
178
32
146
09 167
19 N/A
... ...
... ...
30 135
14 N/A
31 131
14 N/A
TRAN SENSOR
GAIN
(0 -
31)
YYY
3
1
In this example, Gain Number 08 is
chosen because, where both the
Label Value (178) and TOF Value
(32) are above twenty, it delivers the
highest Difference Value (146).