Extended System-Level Command Functions
68
Class Series 2 Programmer’s Manual
Value
Units /
Interpretation
Selection / Definition
L
3 = Delayed
Scan Fault
Increases throughput when bar codes reside near the
trailing edge of the label (in the direction of FEED).
•
If unreadable, the fault will occur after the next
label prints.
•
The label immediately following a faulted label is
not scanned for errors.
•
VOID AND RETRY and REPRINT are automatically
disabled; the job can only be cancelled.
4 = Void Retry
& Cont.
VOID is printed on a faulted label, with reprint attempts
occurring automatically, until the RETRY COUNT has been
exceeded and then that label will be skipped (discarded)
and printing will continue to the next label in queue.
D
Void Distance
(.10 - 2.00)
Sets the distance (.10 - 2.00) to backup the faulted label to
print “VOID” on its trailing edge, which also indirectly
establishes the font size of the void message.
R
Retry Count
(0 – 3)
Establishes the number of times a reprint will be attempted
when using the RFID or Scanner option; if the last label
printed in this count has been voided, a fault will be
declared.
B
Enable / Disable
Y, N
Retract from presented distance prior to feed-clear motion.
This option is intended for use with applicator equipment
that may require certain GPIO signals for proper operation.
Table 5-2: Fault Handling Command
Example:
<STX>KcFHD112<CR>
The example above configures the printer to back up and print a one-inch tall “VOID”
message on a faulted label; if two successive faults occur during the printing of that
label, then the FEED Key must be pressed to clear the fault.
(FM) Feedback Mode –
See
<STX>a
for command details
.
(FS) Slew Speed –
This command controls the rate of label movement between
printing areas when the GPIO port is used; see Appendix L for ranges.
(GD) Display Mode –
This command controls the size of displayed menu
characters, where Enhanced makes them larger.
Summary of Contents for A-Class
Page 2: ......
Page 3: ......
Page 5: ......
Page 6: ......
Page 22: ...Overview 8 Class Series 2 Programmer s Manual ...
Page 30: ...Immediate Command Functions 16 Class Series 2 Programmer s Manual ...
Page 138: ...Extended System Level Command Functions 124 Class Series 2 Programmer s Manual ...
Page 160: ...Label Formatting Command Functions 146 Class Series 2 Programmer s Manual ...
Page 180: ...Generating Label Formats 166 Class Series 2 Programmer s Manual ...
Page 192: ...Appendix B Sample Programs 178 Class Series 2 Programmer s Manual ...
Page 200: ...Appendix D Reset Codes 186 Class Series 2 Programmer s Manual ...
Page 212: ...Appendix E Single Byte Symbol Sets 198 Class Series 2 Programmer s Manual ...
Page 264: ...Appendix G Bar Code Details 250 Class Series 2 Programmer s Manual ...
Page 308: ...Appendix Q Plug and Play IDs 294 Class Series 2 Programmer s Manual ...
Page 312: ...Appendix R Line Mode 298 Class Series 2 Programmer s Manual ...
Page 324: ...Appendix T WiFi Region Country Codes 310 Class Series 2 Programmer s Manual ...
Page 334: ......