STS400™ INSTALLATION MANUAL
48
4
Row 1: Last Reading Result
Row 2:Statistics
Rows 3 and 4: Reading Mask
Good Read
Master and
Slave 1
1234567890
G99% N01% M00% P00%
110000000000000
000000000000000
Good Read
Slave 3 and
Slave 4
1234567890
G99% N01% M00% P00%
000110000000000
000000000000000
No Read
No Read
G99% N01% M00% P00%
000000000000000
000000000000000
4.2.4 Init
Counters
NOTE:
This menu item is only visible if the connected reader is set as
master and the Array Layout Monitor parameter is enabled.
Use the following procedure to reset the Reading Mask statistics to 0:
1. Enter the Menu (by pressing the two arrow buttons simultaneously)
2. Select the "View" item with the arrow buttons and confirm with the middle button.
3. Select the "Init Counters" item with the arrow buttons and confirm with the middle button.
4.3 EXTENDED MENU
Through this menu item the parameters and calibrations of the complete system will be
backed up or restored in the BM100 backup module inside the CBX500 ATS-001.
To perform this procedure, see par. 6.2.2.