SG2 EXTENDED
Instruction Manual
10
1.5. Safety
information
For a correct and safe use of the safety light curtains of the SG2 series, the following points must
be observed:
The stopping system of the machine must be electrically controlled.
This control system must be able to stop the dangerous movement of the machine within the total
machine stopping time T as per paragraph 1.3.3, and during all working cycle phases.
Mounting and connection of the safety light curtain must be carried out by qualified personnel only,
according to the indications included in the special sections (refer to sections 2; 3; 4; 5) and in the
applicable standards.
The safety light curtain must be securely placed in a particular position so that access to the
dangerous zone is not possible without the interruption of the beams (refer section 2 “Installation
mode”).
The personnel operating in the dangerous area must be well trained and must have adequate
knowledge of all the operating procedures of the safety light curtain.
The TEST button must be located outside the protected area because the operator must check the
protected area during all Test operation.
The RESET/RESTART button must be located outside the protected area because the operator
must check the protected area during all Reset/Restart operations.
Please carefully read the instructions for the correct functioning before powering the light curtain.