background image

 

 

This product is covered by one or more of the following patents. 

European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1. 

Italian Patent IT 1,321,772. 

 

S5N-Px

-

-PP/NN

 SERIES 

INSTRUCTION MANUAL 

CONTROLS 

OUTPUT LED (S5N-

Px…A00/B01/C01/C10/C21/D00/E01/F01/T01) 

The yellow LED ON indicates that the NO output status is closed. 

STABILITY LED (S5N-

Px…B01/C01/C21/E01/F01) 

The  green  LED  ON  indicates  that  the  received  signal  has  a  reserve 
greater than 30% compared to the output switching value. 

POWER ON LED (S5N-Px

…G00) 

The green LED indicates that the sensor is operating. 

TRIMMER (S5N-Px

…B01/C01/C21/E01/F01/T01) 

The  trimmer  can  be  used  to  adjust  sensitivity;  the  operating  distance 
increases turning the trimmer clockwise. 
 

WARNING: The trimmer rotation is limited to 270° by a mechanical stop. 
Do not apply excessive torque when adjusting (max 40 Nmm). 

INSTALLATION 

The sensor can be fixed by means of the M18x1 threaded body through 

  18mm  hole,  using  the  specific  washer  and  the  two  CH.24  nuts 

enclosed (1.5Nm maximum tightening torque). 
Alternatively,  the  sensor  can  be  mounted  through  the  two  housing’s 
holes using two screws (M3x22 or longer) and washer. 
Amongst  the  various  possible  solutions,  we  suggest  to  choose  the 
combination that offers the best visibility of the signalling LEDs and the 
easiest access to the trimmer. 
Wide  range  of  accessories  available:  22mm  nuts,  h=8mm,  (2Nm 
maximum tightening torque) guarantee an improved torque and various 
orientable  fixing  brackets  ease  the  sensor 
positioning  (please  refer  to  the  accessories 
listed in the general catalogue). 
The operating distance is measured from the 
front surface of the sensor lens. 

C  models

:  To  improve  the  detection,  the 

object has to be moved closer or further away 
from the front surface of the sensor lens. 
In  case  of  lateral  translation,  the object must 
move as indicated in the figure. 

CONNECTIONS 

The connections are compliant to the EN 60947-5-2 standard. 

 

 

+

 

 

10 … 30 Vdc 

NC OUTPUT 

BROWN 

WHITE 

BLACK 

BLUE 

NO OUTPUT 

0 V 

 

S5N-

Px…G00 

+

 

 

10 … 30 Vdc 

TEST + 

BROWN 

WHITE 

BLACK 

BLUE 

TEST - 

0 V 

 

M12 CONNECTOR 

2

3

1

4

 

 

DIMENSIONS 

24

N°.2 Ø3.8

4

=

2.5

=

4

=

3.8

2

STABILITY LED

10

15

M1

8x1

1.5

14

3.5

24

3.5

1.5

4

4

2

=

3.8

14

12

10

14.5

N°.2 Ø3.8

TRIMMER

15

24

4

4

1.5

12

N°.2 Ø3.8

TRIMMER

39.5

15

M1

8x1

10

14

Ø

22

Ø

2.2

mm

14

=

M1

8x1

6.2

=

Ø4

25

25

25

RADIAL VERSION

FIBRE OPTIC VERSION

TRIMMER

OUTPUT LED

STABILITY LED

OUTPUT LED

OUTPUT LED

STABILITY LED

OUTPUT LED

STABILITY LED

without trimmer

L
X

X1

M O D E L S

with trimmer

X1

X

AXIAL VERSION

without trimmer

L
X

X1

M O D E L S

with trimmer

X

X1

CABLE VERSION

=

M12

=

M12

=

M12

14.5

L

14.5

L

79
43
46

69
42
36

57
42
24

67
43
34

72.5

14.5

10

 

 
 

TECHNICAL DATA 

 

S5N-PA AXIAL VERSION 

S5N-PR RADIAL VERSION

 

Power supply: 

10 … 30 Vdc (limit values) 

Ripple: 

2 Vpp max. 

Current consumption  
(output current excluded): 

35 mA max. 

Outputs: 

NO and NC; PNP or NPN

 

(short-circuit protection) 

Output current: 

100 mA max.  

Output saturation voltage: 

2 V max. 

Response time: 

0.5 ms (2 ms mod.F01/G00) 

Switching frequency: 

1KHz (250 Hz mod.F01/G00) 

Indicators: 

OUTPUT LED (YELLOW) excluding mod.G00 

STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01) 

POWER ON LED (GREEN) (mod.G00) 

Setting: 

sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01) 

Operating temperature: 

-

25 … 55 °C 

Storage temperature: 

-

25 … 70 °C 

Insulating strength: 

500 Vac 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 Vdc, between electronics and housing 

Operating distance (typical values): 

A00: 0.1…4 m on R2 

B01: 0.1…3.5 m on R2 

C01: 0…60 cm 
C10: 0…10 cm 
C21: 0…35 cm 

D00: 0.5…10 cm 

F01/G00: 0…25 m 

E01: 30 mm with OF-42 / 100 mm with OF-43 

T01: 0

.1…1 m on R2 

B01: 0.1…2 m on R2 

C01: 0…35 cm 

C10: 0…8 cm 
D00: 0…8 cm 

F01/G00: 0…20 m 

T01: 0.1…1 m on R2 

Emission type: 

red (630 nm) (mod. D00/E01) / red (660 nm) (mod.B01/T01) / 

infrared (880nm) (mod. A00/C01/C10/C21/G00) 

Ambient light rejection: 

according to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing material: 

PBT  

Lens material: 

PMMA 

Mechanical protection: 

IP67 

Connections: 

2 m cable 

 4 mm / M12 - 4 pole connector 

Weight: 

75 g. max. cable vers. / 25 g. max. connector vers.  

AtEx 2014/34/EU: 

II 3D EX tc IIIC IP67 T85°C 

 

 

SETTING 

Setting of S5N-

Px…A00 

Position the sensor and reflector on opposite sides. 
Find  the  points  where  the  yellow  LED  (OUT)  is  wswitched  ON  and  OFF  in 
both  vertical  and  horizontal  posizionts,  and  fix  the  sensor  in  the  center 
between these points. 

Setting of S5N-

Px…B01/T01 

Position the sensor and reflector on opposite sides. 
Turn the sensitivity trimmer to the maximum position. 
Moving the sensor both vertically and horizontally, determine the power on and off 
points of the yellow LED (OUT) and then mount the sensor in the middle of the 
points defined. Optimum operation is obtained when the green LED (mod.B01) is 
ON and the yellow LED is OFF. 

B01 models

: If necessary reduce sensitivity in order to detect very 

small targets. In order to improve alignment, repeat the procedure 
detailed above whilst progressively reducing the sensitivity. 

T01 model

: Turn the sensitivity trimmer counterclockwise until the 

yellow  LED  turns  ON 

(pos.A). 

Turn  slowly  the  trimmer again clockwise until the 

yellow LED turns OFF 

(Operating condition, pos.B). 

Setting of S5N-

Px…F01/G00/E01 with OF-43 (P/R fibre-optics) 

Position the sensors (fibre terminals) on opposite sides. 
Turn  the  sensitivity  trimmer  to  maximum:  moving  the  sensor  both  vertically  and 
horizontally, determine the power on and off points of the yellow LED (OUT) and 
then mount the sensor in the middle of the points defined. Optimum operation is 
obtained  when  the  green  LED  is  ON  and  the  yellow  LED  is  OFF  (the  output 
function and the relative LEDs are inverted in the E01 model with the OF-43 fibre). 
If  necessary,  reduce  sensitivity  using  the  trimmer,  in  order  to  detect  very  small 
targets. In order to improve alignment, repeat the procedure detailed above whilst 
progressively reducing the sensitivity. 

Setting of S5N-

Px…C01/C21/E01 with OF-42 (proximity fibre) 

Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow LED is 
OFF. Position the target to detect in front of the sensor or of the fibre terminals. 
Turn  the  sensitivity  trimmer  clockwise  until  the  yellow  LED  turns  ON 

(Target 

detected state, pos.A). 

Remove the target, the yellow LED turns OFF. 
Turn the sensitivity trimmer clockwise until the yellow LED turns ON 

(Background 

detected state, pos.B). 

The trimmer reaches maximum if the background is not detected. 
Turn the trimmer to the intermediate position C, between the two positions A and 
B. The green LED must be ON. 

Setting of S5N-

Px…C10/D00 

The operating distance range of these sensors is factory preset: please consider 
this feature when positioning. 

TEST FUNCTION (S5N-

Px…G00) 

The  TEST+  and  TEST-  inputs  can  be  used  to  inhibit  the  emitter  and  verify 
that the system is correctly operating. 
The receiver output should switch when the test is activated while the beam 
is uninterrupted. 
The inputs activating voltage range is 10 … 30 VDC. 
 
 
 
 
 
 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

.. 

 

For information about the disposal of Waste Electrical and 
Electronic Equipment (WEEE), please refer to the website at 

www.datalogic.com

 

 
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED 

 Without limiting the 

rights under copyright, no part of this documentation may be reproduced, stored in or introduced into 
a  retrieval  system,  or  transmitted  in  any  form  or  by  any  means,  or  for  any  purpose,  without  the 
express written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo 
are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All 
other trademarks and brands are property of their respective owners. Datalogic reserves the right to 
make modifications and improvements without prior notification. 
 
 
 

821005704 Rev. E

 

 

MIN 

MAX 

 

Summary of Contents for S5N-PA

Page 1: ...min between electronics and housing Insulating resistance 20 M 500 Vdc between electronics and housing Operating distance typical values background suppression 50 150 mm Emission type RED 630 nm Ambi...

Page 2: ...oniche e contenitore Resistenza d isolamento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici soppr di sfondo 50 150 mm Tipo di emissione rossa 630 nm Reiezione alla...

Page 3: ...grundausblendung 50 150 mm Sender Wellenl nge Rot 630 nm Umgebungshelligkeit gem EN 60947 5 2 Vibration Amplitude 0 5 mm Schaltfrequenz 10 55Hz f r allen Achsen EN60068 2 6 Schockbest ndigkeit 11 ms 3...

Page 4: ...gidit di lectrique 500 Vca 1 min entre composants lectroniques et bo tier R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Distance de d tection valeurs typiques suppr de f...

Page 5: ...2 3 5 M12 S5N PA S5N MA 10 30 Vdc 2 Vpp 30 mA N A N C PNP NPN 100 mA 2 V 1 ms 500 Hz LED LED SET N O LIGHT N C DARK EEPROM 25 55 C 25 70 C 500 Vac 1 min 20 M 500 Vdc 50 150 mm 630 nm EN 60947 5 2 0 5...

Page 6: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 7: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 8: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 9: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 10: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...

Page 11: ...25 70 C Insulating strength 500 Vac 1 min between electronics and housing Insulating resistance 20 M 500 Vdc between electronics and housing Operating distance typical values background suppression 50...

Page 12: ...Vca 1 min tra parti elettroniche e contenitore Resistenza d isolamento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici soppr di sfondo 50 150 mm Tipo di emissione r...

Page 13: ...len und Geh use Tastweiten typische Werte Hintergrundausblendung 50 150 mm Sender Wellenl nge Rot 630 nm Umgebungshelligkeit gem EN 60947 5 2 Vibration Amplitude 0 5 mm Schaltfrequenz 10 55Hz f r alle...

Page 14: ...55 C Temp rature de stockage 25 70 C Rigidit di lectrique 500 Vca 1 min entre composants lectroniques et bo tier R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Distance d...

Page 15: ...D READY ERROR LED OUTPUT LED 10 M12 3 5 M12 S5N PA S5N MA 10 30 Vdc 2 Vpp 30 mA N A N C PNP NPN 100 mA 2 V 1 ms 500 Hz LED LED SET N O LIGHT N C DARK EEPROM 25 55 C 25 70 C 500 Vac 1 min 20 M 500 Vdc...

Page 16: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 17: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 18: ...s Lens material PMMA Mechanical protection IP67 Type 1 enclosure Connections 2 m cable 4 mm M12 4 pole connector Weight 110 g max cable vers 60 g max connector vers AtEx 2014 34 EU II 3D EX tc IIIC IP...

Page 19: ...t IP67 Geh useart 1 Anschluss Kabel mit 2 m L nge 4 mm 4 poliger M12 Stecker Gewicht 110 g max bei Kabelversion 60 g max bei Steckerversion AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C EINSTELLUNG Ausr...

Page 20: ...1 F00 Bo tier laiton nickel Lentilles PMMA Classe de protection IP67 Bo tier type 1 Connexions 2 m c ble 4 mm connecteur M12 4 p les Poids 110 g max versions c ble 60 g max versions connecteur AtEx 20...

Page 21: ...eriale contenitore ottone nichelato Materiale lenti PMMA Protezione meccanica IP67 Contenitore tipo 1 Collegamenti cavo di lunghezza 2 m 4 mm connettore M12 a 4 poli Peso 110 g max vers a cavo 60 g ma...

Page 22: ...1 R2 0 1 2 5 m C01 1 40 cm C10 0 10 cm F00 G00 0 18 m A00 R2 0 1 2 5 m B01 R2 0 1 2 0 m C01 1 30 cm C10 0 8 cm F00 G00 0 15 m 660 nm B01 880 nm A00 C01 C10 G00 EN 60947 5 2 0 5 mm 10 55 Hz EN60068 2 6...

Page 23: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 24: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 25: ...G 6 shock for every axis EN60068 2 27 LIGHT DARK selection white wire or pin 2 connected to 10 30V LIGHT mode to 0V DARK mode white wire or pin 2 not connected LIGHT mode mod C01 C10 DARK mode mod A00...

Page 26: ...n 2 angeschlossen an 10 30 V Hellschaltung 0 V Dunkelschaltung wei er Draht oder Pin 2 nicht angeschlossen Hellschaltung bei Mod C01 C10 und Dunkelschaltung bei Mod A00 B01 F00 Geh usematerial PBT Lin...

Page 27: ...EN60068 2 6 R sistance aux chocs 11 ms 30 G 6 chocs pour chaque axes EN60068 2 27 S lection CLAIRE SOMBRE LIGHT ON fil blanc ou broche 2 connect 10 30V DARK ON 0V Fil blanc ou broche 2 non connect LI...

Page 28: ...tenza agli urti 11 ms 30 G 6 shock per ogni asse EN60068 2 27 Selezione BUIO LUCE filo bianco o pin 2 connesso a 10 30V modo LUCE a 0V modo BUIO filo bianco o pin 2 non connesso modo LUCE mod C01 C10...

Page 29: ...0 R2 0 1 3 5 m B01 R2 0 1 2 5 m C01 1 40 cm C10 0 10 cm F00 G00 0 18 m A00 R2 0 1 2 5 m B01 R2 0 1 2 0 m C01 1 30 cm C10 0 8 cm F00 G00 0 15 m 660 nm B01 880 nm A00 C01 C10 G00 EN 60947 5 2 0 5 mm 10...

Page 30: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 31: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 32: ...e product Two different setting possibilities are available EASY TOUCH a long pressure of the SET pushbutton allows self setting FINE DETECTION to be used onlyin particularlycritical conditions this s...

Page 33: ...na rapida e sicura impostazione del prodotto in autoapprendimento Sono previste due diverse possibilit di impostazione EASY TOUCH con una sola pressione prolungata del tasto SET si ottiene la regolazi...

Page 34: ...tellung nur anwenden wenn die EASYtouchTM Teach In Einstellung nicht ausreichend sein sollte oder wenn kritische Konstellationen bestehen Einstellung S5N PA W Um eine korrekte Einstellung zu erreichen...

Page 35: ...issage EASY TOUCH Il permet un param trage rapide et s r du produit Deuxmodes de r glages sont possibles EASY TOUCH en appuyant sur la touche SET de mani re prolong e on obtient une acquisition standa...

Page 36: ...EN 60947 5 2 0 5 mm 10 55 Hz EN60068 2 6 11 ms 30 G 6 EN60068 2 27 PBT PMMA IP67 1 M12 4 25 g AtEx 2014 34 EU I I 3G EX nA II T6 I I 3D EX tD A22 IP67 T85 C RG0 IEC 62471 EASY TOUCH EASY TOUCH EASY TO...

Page 37: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 38: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 39: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 40: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 41: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...

Page 42: ...otection IP67 Metal versions type 1 enclosure Connections 2 m cable 4 mm M12 4 pole connector Weight 75 g max cable vers 25 g max connector vers 110 g max cable vers 60 g max connector vers AtEx 2014...

Page 43: ...MMA Protezione meccanica IP67 Contenitore tipo 1 versioni metalliche Collegamenti cavo di lunghezza 2 m 4 mm connettore M12 a 4 poli Peso 75 g max vers a cavo 25 g max vers a conn 110 g max vers a cav...

Page 44: ...0 g max Kabel Vers 60 g Stecker Vers AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C Emissionen freie Risikogruppe RG 0 nach IEC 62471 EINSTELLUNG EASY TOUCH Der Sensor verf gt ber die patentierte EASYtou...

Page 45: ...N60068 2 27 Bo tier PBT laiton au nickel Lentilles PMMA Classe de protection IP67 Bo tier type 1 versions en m tal Connexions 2 m c ble 4 mm connecteur M12 4 p les Poids 75 g max versions c ble 25 g m...

Page 46: ...MA 10 30 Vdc 2 Vpp 25 mA N O N C PNP NPN 30 Vcc 100 mA 2 V 100 s 5 kHz 50 s LED LED SET N O LIGHT N C DARK EEPROM 10 55 C 20 70 C 500 Vac 1 min 20 M 500 Vdc 10 mm 2 mm 4 5 mm LED 400 700 nm EN 60947...

Page 47: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 48: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 49: ...G00 Class 1 CDRH 21 CFR PART 1040 10 mod B01 C01 G00 Max power 1 mW Pulse 5 s 645 660 nm Frequency 25 kHz Ambient light rejection According to EN 60947 5 2 Vibrations 0 5 mm amplitude 10 55 Hz freque...

Page 50: ...one LASER ROSSO Classe 1 IEC 60825 1 2014 mod B01 C01 G00 Classe 1 CDRH 21 CFR PART 1040 10 mod B01 C01 G00 Potenza max 1 mW Impulso 5 s 645 660 nm Frequenza 25 kHz Reiezione alla luce ambiente come p...

Page 51: ...utzklasse 1 CRDH 21 CFR Part 1040 10 bei Mod B01 C01 G00 Max Power 1 mW Polse 5 S 645 660 nm Frequenz 25 kHz Umgebungshelligkeit gem EN 60947 5 2 Vibration Amplitude 0 5 mm Schaltfrequenz 10 55Hz f r...

Page 52: ...e 1 IEC 60825 1 2014 mod B01 C01 G00 Classe 1 CDRH 21 CFR PART 1040 10 mod B01 C01 G00 Puissance max 1 mW Dur e de l Impulsion 5 s 645 660 nm fr quence 25 kHz R jection la lumi re ambiante EN 60947 5...

Page 53: ...M18x1 N 2 3 8 6 14 12 4 14 5 14 5 10 M18x1 6 61 M12 10 4 S5N PH S5N MH 10 30 Vdc 2 Vpp 35 mA B01 C01 F01 30 mA G00 N O N C PNP NPN 100 mA 2 V 333 s 1 5 kHz LED B01 C01 F01 LED B01 C01 F01 N O LIGHT N...

Page 54: ...C01 F01 Operating mode LIGHT mode on N O output DARK mode on N C output mod C01 DARK mode on N O output LIGHT mode on N C output mod B01 F01 Operating temperature 10 50 C Storage temperature 25 70 C I...

Page 55: ...D POWER ON VERDE Impostazione trimmer di sensibilit mod B01 C01 F01 Modo operativo modo LUCE su uscita N A modo BUIO su uscita N C mod C01 modo BUIO su uscita N A modo LUCE su uscita N C mod B01 F01 T...

Page 56: ...l bei Ausgang N O Dunkel bei Ausgang N C Mod C01 Dunkel bei Ausgang N O Hell bei Ausgang N C Mod B01 F01 Betriebstemperatur 10 50 C Lagertemperatur 25 70 C Dielektrische Durchschlagsfestigkeit 500 Vca...

Page 57: ...WER ON VERTE Ajustement Potentiom tre de r glage mod B01 C01 F01 Mode operationnel mode CLAIR sur NO mode SOMBRE sur NF mod C01 mode SOMBRE sur NO mode CLAIR sur NF mod B01 F01 Temp rature de fonction...

Page 58: ...67 43 B C F version M O D E L S L X S5N PL S5N ML 10 30 Vdc 2 Vpp 35 mA B01 C01 F01 30 mA G00 N O N C PNP NPN 100 mA 2 V 333 s 1 5 kHz LED B01 C01 F01 LED B01 C01 F01 N O LIGHT N C DARK C01 N O DARK N...

Page 59: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 60: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 61: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 62: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 63: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...

Page 64: ...tance typical values B01 0 1 16 m on R2 C01 0 35 cm F01 G00 0 60 m Emission type RED LASER Class 1 IEC 60825 1 2014 mod B01 C01 G00 Class 1 CDRH 21 CFR PART 1040 10 mod B01 C01 G00 Max power 1 mW Puls...

Page 65: ...a parti elettroniche e contenitore Distanza operativa valori tipici B01 0 1 16 m su R2 C01 0 35 cm F01 G00 0 60 m Tipo di emissione LASER ROSSO Classe 1 IEC 60825 1 2014 mod B01 C01 G00 Classe 1 CDRH...

Page 66: ...B01 0 1 16 m gegen R2 C01 0 35 cm F01 G00 0 60 m Sender Wellenl nge Rotlicht Laser Schutzklasse 1 nach IEC 60825 1 2014 bei Mod B01 C01 G00 Schutzklasse 1 CDRH 21 CFR PART 1040 10 mod B01 C01 G00 Max...

Page 67: ...Distance de d tection valeurs typiques B01 0 1 16 m sur R2 C01 0 35 cm F01 G00 0 60 m Type d mission LASER Rouge Classe 1 IEC 60825 1 2014 mod B01 C01 G00 Classe 1 CDRH 21 CFR PART 1040 10 mod B01 C0...

Page 68: ...version M O D E L S L X S5N PL S5N ML 10 30 Vdc 2 Vpp 35 mA B01 C01 F01 30 mA G00 N O N C PNP NPN 100 mA 2 V 333 s 1 5 kHz LED B01 C01 F01 LED B01 C01 F01 N O LIGHT N C DARK C01 N O DARK N C LIGHT B0...

Page 69: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 70: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 71: ...perature 25 55 C Storage temperature 25 70 C Insulating strength 500 Vac 1 min between electronics and housing Insulating resistance 20 M 500 Vdc between electronics and housing Operating distance typ...

Page 72: ...25 70 C Rigidit dielettrica 500 Vca 1 min tra parti elettroniche e contenitore Resistenza d isolamento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici Tasteggio 15...

Page 73: ...use Isolationswiderstand 20 M 500 Vdc zwischen elektronischen Teilen und Geh use Tastweite typische Werte Tastweite 15 100 mm Hintergrundausblendung 50 100 mm Sender Wellenl nge rot 670 nm Umgebungsh...

Page 74: ...e de stockage 25 70 C Rigidit di lectrique 500 Vca 1 min entre composants lectroniques et bo tier R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Port e op rationnelle val...

Page 75: ...33 M18 M12 OUTPUT LED STABILITY LED SET PUSHBUTTON S5N PS S5N MS 10 30 Vdc 2 Vpp 30 mA NO NC PNP NPN 100 mA 2 V 1 ms 500 Hz LED LED SET NO LIGHT NC DARK EEPROM 25 55 C 25 70 C 500 Vac 1 min 20 M 500 V...

Page 76: ...ic parts and housing Operating distance typical values B01 0 1 3 5 m on R2 C01 0 60 cm B01 0 1 2 m on R2 C01 0 35 cm Emission type red 630 nm mod E01 red 660 nm mod B01 T01 infrared 880 nm mod C01 C21...

Page 77: ...mento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici B01 0 1 3 5 m su R2 C01 0 60 cm B01 0 1 2 m su R2 C01 0 35 cm Tipo di emissione rossa 630 nm mod E01 rossa 660...

Page 78: ...rte B01 0 1 3 5 m gegen R2 C01 0 60 cm B01 0 1 2 m gegen R2 C01 0 35 cm Sender Wellenl nge ROT 630 nm bei Mod E01 ROT 660 nm bei Mod B01 T01 INFRAROT 880 nm bei Mod A00 C21 G00 Umgebungshelligkeit gem...

Page 79: ...R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Distance de d tection valeurs typiques B01 0 1 3 5 m sur R2 C01 0 60 cm B01 0 1 2 m sur R2 C01 0 35 cm Type d mission roug...

Page 80: ...4 5 61 14 5 10 TRIMMER S5N MA S5N MR 10 30 Vdc 2 Vpp 35 mA N O N C PNP NPN 100 mA 2 V 0 5 ms F01 G00 2 ms 1 kHz F01 G00 250 kHz LED G00 LED B01 C01 C21 E01 F01 LED G00 B01 C01 C21 E01 F01 T01 25 55 C...

Page 81: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 82: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 83: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 84: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 85: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...

Page 86: ...ax connector vers AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C SETTING Setting of S5N Mx A00 Position the sensor and reflector on opposite sides Find the points where the yellow LED OUT is switched ON...

Page 87: ...cavo 60 g max vers a connettore AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C REGOLAZIONI Regolazione S5N Mx A00 Posizionare il sensore e il riflettore su lati opposti Determinare i punti di accensione...

Page 88: ...4 34 EU II 3D EX tc IIIC IP67 T85 C EINSTELLUNG Ausrichtung S5N Mx A00 Montieren Sie den Sensor und den Reflektor gegen berliegend Ermitteln Sie durch vertikale und horizontale Bewegung die Einschalte...

Page 89: ...U II 3D EX tc IIIC IP67 T85 C REGLAGES R glage S5N Mx A00 Placer le capteur et le r flecteur sur des c t s oppos s D terminer les points d allumage et d extinction de la LED jaune OUT dans la directio...

Page 90: ...mA 2 V 0 5 ms F01 G00 2 ms 1 kHz F01 G00 250 kHz LED G00 LED B01 C01 C21 E01 F01 LED G00 B01 C01 C21 E01 F01 T01 25 55 C 25 70 C 500 Vac 1 min 20 M 500 Vdc A00 R2 0 1 4 M B01 R2 0 1 3 5 m C01 0 60 cm...

Page 91: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 92: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Page 93: ...e temperature 25 70 C Insulating strength 500 Vac 1 min between electronics and housing Insulating resistance 20 M 500 Vdc between electronics and housing Operating distance typical values B01 0 1 3 5...

Page 94: ...mento 25 70 C Rigidit dielettrica 500 Vca 1 min tra parti elettroniche e contenitore Resistenza d isolamento 20 M 500 Vcc tra parti elettroniche e contenitore Distanza operativa valori tipici B01 0 1...

Page 95: ...len und Geh use Isolationswiderstand 20 M 500 Vdc zwischen elektronischen Teilen und Geh use Reich Tastweiten typische Werte B01 0 1 3 5 m gegen R2 C01 0 60 cm T01 0 1 1 m gegen R2 B01 0 1 2 m gegen R...

Page 96: ...trique 500 Vca 1 min entre composants lectroniques et bo tier R sistance d isolement 20 M 500 Vcc entre composants lectroniques et bo tier Distance de d tection valeurs typiques B01 0 1 3 5 m sur R2 C...

Page 97: ...14 5 L 14 5 L 79 43 46 69 42 36 57 42 24 67 43 34 72 5 14 5 10 S5N PA S5N PR 10 30 Vdc 2 Vpp 35 mA NO NC PNP NPN 100 mA 2 V 0 5 ms F01 G00 2 ms 1kHz F01 G00 250 kHz LED G00 LED B01 C01 C21 E01 F01 LED...

Page 98: ...e Description Data Type Access 0x000C 12 Device Access Locks 2 octets Bit 0 Parameter write access 0 unlocked 1 locked Bit 1 Data Storage 0 unlocked 1 locked Standardized Device locking functions Bit...

Page 99: ...ic RO 0x0029 41 Process Data Output 1 octet Read last valid Process Data Output from PDout channel Device specific RO 0x0052 82 Device Temperature 2 octets 2 octets 2 octets 2 octets 2 octets 1 64 2 4...

Page 100: ...0 High Active default B01 T01 0x01 Low Active default C01 0x01 Single Point default DO pin configuration UIntegerT UIntegerT R W Saved in non volatile memory 2 octets 3 0 Not used M03 0 10 Hysteresis...

Page 101: ...Warning Out of specification only B01 C01 T01 0x4210 16912 Temperature overrun Appears Disappears Warning Out of specification 0x5100 20736 General power supply fault Appears Disappears Error Failure...

Page 102: ...ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont sujette...

Page 103: ...k resistance 11 ms 30 G 6 shock for every axis EN60068 2 27 Housing material PBT Lens material PMMA Mechanical protection IP67 Connections 2 m cable 4 mm M12 4 pole connector Weight 75 g max cable ver...

Page 104: ...30 G 6 shock per ogni asse EN60068 2 27 Materiale contenitore PBT Materiale lenti PMMA Protezione meccanica IP67 Collegamenti cavo di lunghezza 2 m 4 mm connettore M12 a 4 poli Peso 75 g max vers a c...

Page 105: ...60068 2 27 Geh use PBT Linsen PMMA Schutzart IP67 Anschlu 2 m Kabel 4 mm oder M12 Stecker 4 polig Gewicht 75 g max Kabel Version oder 25 g Stecker Version AtEx 2014 34 EU II 3D EX tc IIIC IP67 T85 C E...

Page 106: ...s pour chaque axes EN60068 2 27 Bo tier PBT Lentilles PMMA Classe de protection IP67 Connexions 2 m c ble 4 mm connecteur M12 4 p les Poids 75 g max versions c ble 25 g max versions connecteur AtEx 20...

Page 107: ...10 S5N PA S5N PR 10 30 Vdc 2 Vpp 35 mA NO NC PNP NPN 100 mA 2 V 0 5 ms F01 G00 2 ms 1kHz F01 G00 250 kHz LED G00 LED B01 C01 C21 E01 F01 LED G00 B01 C01 C21 E01 F01 T01 25 55 C 25 70 C 500 Vac 1 min...

Page 108: ...DR CKLICHEN STILLSCHWEIGENDEN GESETZLICHEN ODER GARANTIE Datalogic garantit que les Produits seront exempts de d fauts de mat riaux et de fabrication dans le cadre d une utilisation normale et appropr...

Page 109: ...ahmen zu ergreifen FR Conformit CE La marque CE indique la conformit du produit aux exigences essentielles nonc es dans la directive europ enne applicable Les directives et les normes applicables sont...

Reviews: