background image

Hex-Numeric Keypad

Quick Reference Guide

43

Hex-Numeric Keypad

Use the bar codes that follow to enter numbers as you 
would select digits/characters from a keypad.

0

1

2

3

4

5

Summary of Contents for QuickScan QBT21 Series

Page 1: ...QuickScan QBT21X1 General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide...

Page 2: ...ntative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggest...

Page 3: ...Devices to Base 10 Linking to a Bluetooth Adapter in Serial Port Profile Mode 11 Linking to a Bluetooth Adapter in HID mode 11 Variable PIN Code 13 Programming 14 Using Programming Bar Codes 14 Confi...

Page 4: ...24XX Warranty Claims Process 37 Warranty Exclusions 38 No Assignment 39 Risk of Loss 39 Ergonomic Recommendations 40 Cleaning 41 Support Through the Website 42 Hex Numeric Keypad 43 For HID Variable P...

Page 5: ...arked appropriately or identified as proprietary or confiden tial and c any information that End User under the circumstances should recognize as confidential Proprietary Information does not include...

Page 6: ...End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licensors to any person other than End User s authorized employees or agen...

Page 7: ...of the United Nations Convention on International Sale of Goods shall not apply to this Agreement 10 Termination 10 1 Either party may terminate this Agreement or any license granted under this Agreem...

Page 8: ...courts of any other state country or territory in which End User resides or in which any of End User s assets are located In the event an action is brought to enforce the terms and conditions of this...

Page 9: ...and light industrial envi ronments Omni Directional Operation To read a symbol simply aim the reader and pull the trigger The QuickScan QBT21X1 reader is a versatile linear imager featuring a wide sc...

Page 10: ...ion see page 10 4 Select the Interface Type see page 21 5 Configure the Reader starting on page 14 optional depends on settings needed Locking the Reader to the Base The Base Station provides a lockin...

Page 11: ...by pushing up the lever as far as it will go Figure 2 Lever in locked position NOTE It is good practice to put the reader in the locked condition at the end of the working shift or when not in use for...

Page 12: ...g 1 Remove the rubber Cable Stopper from the bottom of the Base Station 2 Securely plug the Power Cable if used and Interface I F Cable connectors into their respective ports in the underside of the B...

Page 13: ...connection that the reader s cable type is compatible with your host equipment NOTE The QuickScan QBT21X1 can be set up to require a PIN code when connecting to the host If you are adding new equipme...

Page 14: ...the keyboard and the remaining end at the key board port on the terminal PC Figure 4 Connecting to the Host Power Connection Plug the AC Adapter into an approved AC socket If plugged into the wall ens...

Page 15: ...gure 6 QuickScan Base LEDs Table 1 Radio Base LEDs LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On the Ba...

Page 16: ...charged by connecting the reader directly to a host through the micro USB connector available in the bottom of the handle as shown Replacing the Battery Pack 1 Using a coin or screwdriver unscrew the...

Page 17: ...he battery pack downward while pressing the bottom side of the battery pack to seat securely into the contact springs so that the edges of the pack and the handle board are aligned while securing the...

Page 18: ...der Link Datalogic RF Devices to Base For RF devices before configuring the interface it is nec essary to link the handheld with the base To link the handheld and the base press the trigger to wake up...

Page 19: ...s and select Datalogic Scanner If you receive an error message it may be necessary to disable security on the device 4 Use an RS 232 terminal program to see incom ing data on the port designated by th...

Page 20: ...esignated by the computer s Bluetooth manager NOTE The QBT21X1 can be set up to require a PIN code when connecting If you want to set up a PIN or when adding new equipment to a sys tem that uses a cus...

Page 21: ...der is waiting for an alphanumeric entry enter the required variable PIN Code by scanning the cor responding bar codes in the Hex Numeric Keypad sec tion at the back of this manual for alphanumeric en...

Page 22: ...enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure...

Page 23: ...Mode Read the configuration command label below for the HID Alt Mode feature Power Off Scan the bar code below to shut off power to the handheld until the next trigger pull PowerOff ENTER EXIT PROGRA...

Page 24: ...d Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key en...

Page 25: ...E continued Country Mode Britain Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Supports only the interface...

Page 26: ...COUNTRY MODE continued Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Supports only the interfaces listed in the...

Page 27: ...e 19 COUNTRY MODE continued Country Mode Portugal Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the...

Page 28: ...y board and keyboard wedge interfaces It does not apply when an alternate key encoding keyboard is selected NOTE The following bar codes can be used either while in HID mode when reader is connected u...

Page 29: ...ults and additional information associated with each interface proceed to the corresponding chapter in the Quick Scan Q21X1 PRG Configuring the Interface Scan the programming bar code which selects th...

Page 30: ...S232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB COM to simulate RS 232 standard interface Select USB COM STDa a Download the correct USB COM...

Page 31: ...AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286...

Page 32: ...D XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 3...

Page 33: ...configured through the base See Country Mode on page 16 for programming bar codes and informa tion Caps Lock State This option specifies the format in which the reader sends character data See Caps Lo...

Page 34: ...n specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard NUMLOCK ENTER EXIT P...

Page 35: ...a good read green spot Use the bar codes below to specify the duration of the good read pointer beam after a good read GOOD READ GREEN SPOT DURATION ENTER EXIT PROGRAMMING MODE Green Spot Duration Dis...

Page 36: ...released scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads whil...

Page 37: ...odes Quick Reference Guide 29 SCAN MODES Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode CSNRM01 C...

Page 38: ...y Type Li Ion battery pack Typical charge time for full charge from full discharge 6 hours with Host Power through the micro USB cable connection 4 hours with Base and 12V external power supply adapte...

Page 39: ...13 mils DOF based on EAN All other codes are Code 39 All labels grade A typical environmental light 20 C label inclination 10 Symbology Code 39 4 mils 3 0 to 11 0 cm 1 2 to 4 3 in 5 mils 2 0 to 15 0 c...

Page 40: ...S1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Truncated DATABAR Expanded Coupon EAN128 GS1 128 code 4 code 5 BC412 Interfaces Supporteda RS 232 Std RS 232 Wincor Nixd...

Page 41: ...rticulates IEC 529 IP42 scanner only ESD Level Air Discharge 16 kV Regulatory See the Regulatory Addendum Radio Features Frequency Range 2400 to 2483 5 MHz Range in open air 25 m typical a See Interfa...

Page 42: ...highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indication is configurable via thefeature Good Read When to Indica...

Page 43: ...Label A label has been rejected N A Reader sounds three times at lowest fre quency and cur rent volume Label Program ming Mode Accep tance of Partial Label In cases where multiple labels must be scann...

Page 44: ...Configuration Contact Helpdesk for assis tance 2 Interface PCB 6 Digital PCB 12 Imager Indication LEDs Power up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is no...

Page 45: ...ts subassemblies or products that have been tested as meeting applicable specifications for equivalent new material and products Customer will allow Datalogic to scrap all parts removed from the repai...

Page 46: ...h has been damaged modified altered repaired or upgraded by other than Datalogic service personnel or its authorized representatives ii any claimed defect failure or damage which Datalogic determines...

Page 47: ...NG FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATE MENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUM...

Page 48: ...rect heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures...

Page 49: ...a good connection Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol...

Page 50: ...RAL DUTY HANDHELD SCANNERS category link From this page you can select your product model from the dropdown list which gives you access to Downloads including Data Sheets Manuals Software Utilities an...

Page 51: ...Hex Numeric Keypad Quick Reference Guide 43 Hex Numeric Keypad Use the bar codes that follow to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Page 52: ...Hex Numeric Keypad 44 QuickScan QBT21X1 Hex Numeric Keypad continued 6 7 8 9 A B...

Page 53: ...D E F For HID Variable Pin Code only If you make a mistake scan the CANCEL barcode below to abort and not save the entry string You can then restart Finish by scanning the Exit HID Variable PIN Code l...

Page 54: ...Hex Numeric Keypad 46 QuickScan QBT21X1 NOTES...

Page 55: ...Hex Numeric Keypad Quick Reference Guide 47 NOTES...

Page 56: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 U S A Telephone 541 68...

Reviews: