background image

Global AIM ID

Product Reference Guide

        

                   

261

Global AIM ID

AIM label identifiers (as opposed to custom characters you select yourself as with label identifi-
ers) can be included with scanned bar code data. AIM label identifiers consist of three characters 
as follows:

A close brace character (ASCII ‘]’), followed by...

A code character (see the table below), followed by...

A modifier character (the modifier character is symbol dependent).

Figure 8. AIM ID

NOTE

This feature enables/disables addition of AIM IDs for all symbology
types.

SYMBOLOGY

CHAR

SYMBOLOGY

CHAR

UPC/EAN

E

a

a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs.

Code 128/GS1-128

C

Code 39 and 
Code 32

A

GS1 DataBar Omnidirec-
tional, GS1 DataBar 
Expanded

e

Codabar

F

Standard 2 of 5

S

Interleaved 2 of 5

I

ISBN

X

b

b. ISBN (X with a 0 modifier character)

Code 93

G

Code 11

H

Prefix

Su

ffix

L

ab

el ID

L

ab

el ID

B

a

r Code D

a

t

a

AIM ID

Summary of Contents for QuickScan Lite 21 Series

Page 1: ...QuickScanTM Lite QW2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide...

Page 2: ...Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or sugges...

Page 3: ...9 Software Version Transmission 10 Resetting the Product Configuration to Defaults 10 Chapter 3 Interfaces 11 Interface Selection 11 Configuring the Interface 11 Global Interface Features 15 Host Comm...

Page 4: ...ndicate Transmission Failure 51 Disable Character 51 Enable Character 52 Chapter 7 Keyboard Interface 53 Introduction 53 Standard Factory Settings 53 Scancode Tables 53 Country Mode 54 Caps Lock State...

Page 5: ...acter Transmission 91 EAN 13 Flag 1 Character 92 EAN 13 ISBN Conversion 92 ISSN Enable Disable 93 EAN 13 Minimum Reads 93 EAN 8 94 EAN 8 Enable Disable 94 EAN 8 Check Character Transmission 94 Expand...

Page 6: ...30 Code 39 Quiet Zones 131 Code 39 Minimum Reads 132 Code 39 Decoding Level 133 Code 39 Length Control 134 Code 39 Set Length 1 135 Code 39 Set Length 2 136 Code 39 Interdigit Ratio 137 Code 39 Charac...

Page 7: ...acter Transmission 173 Codabar Start Stop Character Transmission 173 Codabar Start Stop Character Set 174 Codabar Start Stop Character Match 175 Codabar Quiet Zones 176 Codabar Minimum Reads 177 Codab...

Page 8: ...128 Force Concatenation 212 ISBT 128 Advanced Concatenation Options 212 MSI 213 MSI Enable Disable 213 MSI Check Character Calculation 213 MSI Check Character Transmission 214 MSI Length Control 214 M...

Page 9: ...character Delay 250 ACK Character 251 NAK Character 252 ACK NAK Timeout Value 253 ACK NAK Retry Count 254 Disable Character 255 Enable Character 256 Wedge Quiet Interval 257 Intercharacter Delay 258 I...

Page 10: ...Scancode Tables 301 Control Character Emulation 301 Interface Type PC AT PS 2 or USB Keyboard 302 Interface type PC AT PS 2 Alt Mode or USB Keyboard Alt Mode 304 Digital Interface 306 IBM XT 308 Micr...

Page 11: ...a serial or USB cable and can also create configuration bar codes to print Manual Overview Chapter 1 Introduction provides a product overview unpacking instructions and cable connection information Ch...

Page 12: ...rtain parameter set tings Appendix F Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces Manual Conventions The following conventions are used in this d...

Page 13: ...are updates demos and instructions for returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A resel...

Page 14: ...Introduction 4 QuickScanTM Lite QW2100 NOTES...

Page 15: ...eyboard Wedge KBW When connected using this interface the host interprets scanned data as keystrokes and supports several international keyboards for the Win dows environment See Country Mode on page...

Page 16: ...e cable clip with its opening as shown in the insert portion of Figure 1 RS 232 Serial Connection Turn off power to the terminal PC and connect the reader to the terminal PC serial port via the RS 232...

Page 17: ...ions Hands Free Stand An accessory is available which holds the reader at a convenient angle allowing hands free scanning of items Press in on the release buttons on both sides of the stand to raise t...

Page 18: ...used as a holder to mount the reader on a wall or other vertical position as shown in Figure 5 Figure 5 Using the Wall Holder Programming The reader is typically factory configured with a set of defa...

Page 19: ...system s correct interface type Configure Interface Settings The reader is typically factory configured with a set of default features standard to the interface type you ordered If after scanning the...

Page 20: ...ns and want to restore the Factory Configuration you have two options You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Con figuration bar code below Both labels re...

Page 21: ...d to Next proceed to the corresponding chap ter in this manual also listed in Table 1 to configure any desired settings and features associ ated with that interface NOTE Unlike some other programming...

Page 22: ...P HA12 P Select RS232 WN RS 232 Wincor Nixdorf RS 232 for use with OPOS UPOS JavaPOS P HA13 P Select RS 232 OPOS P HA13 P Select USB COM STDa USB Com to simulate RS 232 standard interface USB OEM FEA...

Page 23: ...ures starting on page 53 P HA11 P Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key P...

Page 24: ...100 KEYBOARD cont FEATURES USB Keyboard with standard key encoding P HA35 P Select USB Keyboard Set KEYBOARD WEDGE Interface Features starting on page 53 P HA2B P Select USB Alternate Keyboard USB Key...

Page 25: ...ONLY Interface on page 37 RS 232 USB Com Interfaces on page 43 Keyboard Interface on page 53 USB OEM Interface on page 65 Host Commands Obey Ignore This option specifies whether the reader will obey o...

Page 26: ...ScanTM Lite QW2100 ENTER EXIT PROGRAMMING MODE USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode CUSSE00 USB Suspend Mode Disable CUSSE01 USB Suspend M...

Page 27: ...f the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Timeout does not apply to scan modes that require a trigg...

Page 28: ...MODE Double Read Timeout continued CSNDR32 Double Read Timeout 0 5 Second CSNDR3C Double Read Timeout 0 6 Second CSNDR46 Double Read Timeout 0 7 Second CSNDR50 Double Read Timeout 0 8 Second CSNDR5A D...

Page 29: ...lliseconds to 2 550 milliseconds 2 55 sec onds in 10ms increments Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read See Label Gone Timeout on page...

Page 30: ...r power consumption state after being idle no scanner activity for one second NOTE RS 232 and USB interfaces ONLY A reader having a Scan Mode setting of Object Sense Stand Mode Flashing or Always On w...

Page 31: ...ONLY A reader having a Scan Mode setting of Object Sense Stand Mode Flashing or Always On will not enter Sleep Mode The reader is always internally active when in these modes CSLTO00 Sleep Mode Timeo...

Page 32: ...R EXIT PROGRAMMING MODE LED and Beeper Indicators Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power CBPPU00 Power On Alert Disable No Audible Indicat...

Page 33: ...D upon successfully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then active NOTE This option which uses...

Page 34: ...QuickScanTM Lite QW2100 ENTER EXIT PROGRAMMING MODE Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound CBPTY00 Good Read Beep Type Mono CBPTY01 Good Read Beep T...

Page 35: ...und at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone Good Read Beep Length Specifies the duration of a good read beep CBPFR00 Good Read Beep...

Page 36: ...h continued CBPLE08 Good Read Beep Length 80 msec CBPLE0A Good Read Beep Length 100 msec CBPLE0C Good Read Beep Length 120 msec CBPLE0E Good Read Beep Length 140 msec CBPLE10 Good Read Beep Length 160...

Page 37: ...ion during a good read beep NOTE Setting this configuration item to turn off illumination during the beep reduces the peak current drawn by the reader in some scanning modes CBPIC00 Illumination Contr...

Page 38: ...ood Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels CBPVO00 Good Read Beep Volume Beeper Off CBPVO01 Good Read Beep Volume Low CBPVO0...

Page 39: ...on time can be set within a range of 0 1 to 25 5 seconds in 100ms increments See Good Read LED Duration on page 245 for more detailed programming instruc tions CLAGL Select Good Read LED Duration Sett...

Page 40: ...n Mode on page 246 for more detailed programming instructions CSNRM00 Scan Mode Trigger Single CSNRM01 Scan Mode Trigger Hold Multiple CSNRM02 Scan Mode Trigger Pulse Multiple CSNRM03 Scan Mode Flashi...

Page 41: ...er the trigger is pulled while in Stand Mode NOTE This timeout is only used when the Scan Mode is configured as Stand Mode CSNOT01 Stand Mode Triggered Timeout 0 5 Seconds CSNOT03 Stand Mode Triggered...

Page 42: ...ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout continued CSNOT0C Stand Mode Triggered Timeout 6 Seconds CSNOT10 Stand Mode Triggered Timeout 8 Seconds CSNOT00 Stand Mode Triggered Timeout Sw...

Page 43: ...d increments See Scan ning Active Time on page 247 for more detailed programming instructions Stand Mode Flash Enables disables the LED flash when the reader is in Stand Mode CSNET Select Scanning Act...

Page 44: ...ime for the indicator LED while in Flash Mode The selectable range is 100 to 9 900 milliseconds 0 1 to 9 9 seconds in 100 millisecond increments See Flash Off Time on page 249 for more detailed progra...

Page 45: ...ING MODE Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and high DEFAULT 06 Flash is OFF for 600ms CSMSE00 Stand Mode Sensitivity Low CSMSE01 Stand Mode...

Page 46: ...Spot Duration Specifies the duration of the good read pointer beam after a good read CLSSP00 Green Spot Duration Disable Green Spot is Off CLSSP01 Green Spot Duration Short 300 msec CLSSP02 Green Spo...

Page 47: ...ces are available in Chapter 6 RS 232 USB Com Inter faces RS 232 Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Baud Rate Baud rate is the...

Page 48: ...terface 38 QuickScanTM Lite QW2100 ENTER EXIT PROGRAMMING MODE Baud Rate continued CR2BA03 Baud Rate 9600 CR2BA04 Baud Rate 19 200 CR2BA05 Baud Rate 38 400 CR2BA06 Baud Rate 57 600 CR2BA07 Baud Rate 1...

Page 49: ...end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one...

Page 50: ...e according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are...

Page 51: ...d RTS CTS RTS is asserted during transmissions CTS gates transmissions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserte...

Page 52: ...RS 232 ONLY Interface 42 QuickScanTM Lite QW2100 NOTES...

Page 53: ...B Com Interfaces Introduction The programming bar codes in this chapter allow modifications to the standard RS 232 and USB Com interfaces Standard Factory Settings Reference Appendix B Standard Defaul...

Page 54: ...e set within a range of zero 0 to 990 milliseconds in 10ms increments A setting of zero specifies no delay See Intercharacter Delay on page 250 for more detailed programming instructions CR2IC00 Inter...

Page 55: ...al line BEL is issued to gain a user s attention to an illegal entry or other important event Beep On Not on File This option enables disables the action of the reader to sound a three beep sequence u...

Page 56: ...sable Enable for label transmission The reader expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The reader will respond with ACK NAK when the host sen...

Page 57: ...to 0xFF can be selected See NAK Character on page 252 for more detailed programming instructions NOTE Setting to previously defined characters such as XON XOFF or host commands conflicts with normal...

Page 58: ...The selectable timeout range is 200 milliseconds to 15 000ms 15 seconds in 200ms increments A selection of 0 disables the timeout See ACK NAK Timeout Value on page 253 for more detailed programming i...

Page 59: ...e selectable range is from 1 to 254 retries A selection of 0 disables the count and a selection of 255 specifies unlimited retries See ACK NAK Retry Count on page 254 for more detailed programming ins...

Page 60: ...errors detected while waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character CR2EH00 ACK NAK Error Hand...

Page 61: ...aracters or any hex value from 0 to 0xFF can be selected See Disable Character on page 255 for more detailed programming instructions CR2TF00 Indicate Transmission Failure Disable Indication CR2TF01 I...

Page 62: ...alue from 0 to 0xFF can be selected See Enable Character on page 256 for more detailed programming instructions NOTE Setting to previously defined characters such as XON XOFF or host commands conflict...

Page 63: ...apter to select options for USB Keyboard and Wedge Interfaces Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Scancode Tables Information ab...

Page 64: ...encoding Keyboard Wedge All other interfaces support ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden CKBCO00 Country Mode U S CKBCO01 Country Mode Belgium CKBCO0...

Page 65: ...04 Country Mode France CKBCO05 Country Mode Germany Supports only the interfaces listed in the Country Mode feature description CKBCO0D Country Mode Hungary CKBCO06 Country Mode Italy Supports only th...

Page 66: ...he Country Mode feature description CKBCO08 Country Mode Portugal CKBCO10 Country Mode Romania Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces...

Page 67: ...key encoding keyboard is selected Numlock This option specifies the setting of the Numbers Lock Numlock key while in Keyboard Wedge interface This only applies to alternate key encoding interfaces It...

Page 68: ...EXIT PROGRAMMING MODE Keyboard Numeric Keypad This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad CKBKP00 Keyboard Numeric Keypad Standard Keys CKB...

Page 69: ...e are transmitted in the for mat Ctrl Key Special keys are available in the range from 81H to A1 Send Ctrl Shift Key The behavior is the same as above but control keys are sent in the format Ctrl Shif...

Page 70: ...ata to host The selectable range for this feature is from 0 to 990ms in 10ms increments See Wedge Quiet Interval on page 257 for more detailed programming instructions NOTE This feature applies ONLY t...

Page 71: ...990 milliseconds in 10ms increments A setting of zero specifies no delay See Intercharacter Delay on page 258 for more detailed programming instructions NOTE This feature applies ONLY to the Keyboard...

Page 72: ...t for this interface The selectable range for this feature is from 0 to 99 seconds See Intercode Delay on page 259 for more detailed programming instructions CKBID Set Intercode Delay Make a mistake S...

Page 73: ...peed This option specifies the USB poll rate for a USB Keyboard NOTE This feature applies ONLY to the USB Keyboard interface CKBSP01 USB Keyboard Speed 1ms CKBSP02 USB Keyboard Speed 2ms CKBSP03 USB K...

Page 74: ...anTM Lite QW2100 ENTER EXIT PROGRAMMING MODE USB Keyboard Speed continued CKBSP06 USB Keyboard Speed 6ms CKBSP07 USB Keyboard Speed 7ms CKBSP08 USB Keyboard Speed 8ms CKBSP09 USB Keyboard Speed 9ms CK...

Page 75: ...ich host type the reader will be connected with Use the feature settings in this chapter to specifically configure for the USB OEM interface Other USB interfaces are included in the approprite chapter...

Page 76: ...te Options are Table Top Scanner Handheld Scanner USB OEM Interface Options This setting provides for an interface specific control mechanism Options are Obey Obey Reader Configuration Host Commands I...

Page 77: ...th all symbologies or only with specific symbolo gies Figure 6 shows the available elements you can add to a message string Figure 6 Breakdown of a Message String NOTE Additional advanced editing is a...

Page 78: ...r from the ASCII Chart from 00 FF on the inside back cover of this manual as a prefix suffix or Label ID Enter prefixes and suffixes in the order in which you want them to appear on the output Global...

Page 79: ...nstructions GS1 128 AIM ID If Global AIM ID is disabled the AIM ID for GS1 128 can be enabled disabled independently The AIM ID for GS1 128 is a C1 C2 or C3 AIM IDs for other symbologies can be enable...

Page 80: ...r Symbology on page 71 If you wish to program the reader to always include an indus try standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 69 Label ID Pre...

Page 81: ...for a given sym bology type NOTE This setting requires the scanning of bar codes from multiple sec tions See Label ID Set Individually Per Symbology on page 264 for more detailed programming instruct...

Page 82: ...which a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CABID Set UPC A Label ID Character s CA2ID Set UPC A P2 Label ID Character s CA5ID Se...

Page 83: ...ch a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CE5ID Set UPC E P5 Label ID Character s CE8ID Set UPC E GS1 128 Label ID Character s C3B...

Page 84: ...l ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions C8BID Set EAN 8 Label ID Character s C82ID Set EAN 8 P2 Label ID Character s C85ID Set EAN 8 P5 L...

Page 85: ...ch a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CLBID Set GS1 DataBar Limited Label ID Character s CC3ID Set Code 39 Label ID Character...

Page 86: ...is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CI2ID Set Interleaved 2 of 5 Label ID Character s CHRID Set Interleaved 2 of 5 CIP HR Label ID Charact...

Page 87: ...a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CS2ID Set Standard 2 of 5 Label ID Character s CU2ID Set Industrial 2 of 5 Label ID Charac...

Page 88: ...cts the symbology for which a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CC9ID Set Code 93 Label ID Character s CCFID Set Codablock F La...

Page 89: ...ed Label ID Symbology Selection continued This option selects the symbology for which a Label ID is to be configured See Label ID Set Individually Per Symbology on page 264 for full instructions CISID...

Page 90: ...ters M I and D as a Label ID the chart indicates its associated hex characters as 4D4944 Turn to Keypad starting on page 297 and scan the bar codes representing the hex characters determined For the e...

Page 91: ...se of all alphabetic characters to upper or lower case NOTE Case conversion affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data CLFCA00 Case Conversion...

Page 92: ...hexadecimal ASCII values The first character in the pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in a pair i...

Page 93: ...ost widely used set of standard factory settings That section also provides space to record any custom settings needed or implemented for your system UPC A Datalogic 2 of 5 UPC E Codabar EAN 13 ABC Co...

Page 94: ...ng Enable only GS1 DataBar enables only GS1 DataBar coupon decoding To set this feature 1 Scan the Enter Exit bar code 2 Scan either the enable or disable bar code below You ll need to cover any unuse...

Page 95: ...le When disabled the reader will not read UPC A bar codes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A bar code data CABEN00 UPC A Disable CAB...

Page 96: ...so changes the sym bology ID to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system character CAB3B00 UPC A...

Page 97: ...coded before it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 1...

Page 98: ...isable When disabled the reader will not read UPC E bar codes UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E bar code data CEBEN00 UPC E Disable...

Page 99: ...AN 13 data format Selecting this feature also changes the sym bology ID to match those required for EAN 13 Expand UPC E to UPC A Expands UPC E data to the UPC A data format CEB3B00 UPC E to EAN 13 Don...

Page 100: ...haracter UPC E Minimum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as good read CEBNS00 UPC E Number System Character Do no...

Page 101: ...e When disabled the reader will not read EAN 13 JAN 13 bar codes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 bar code data C3BEN00 EAN 13 D...

Page 102: ...The Flag 1 character is the first character of the label EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookland labels starting with 978 to ISBN labels C3BF100 EAN 13...

Page 103: ...g with 977 to ISSN labels EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read C3BIN00 ISSN Disable C3...

Page 104: ...isable When disabled the reader will not read EAN 8 JAN 8 bar codes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar code data C8BEN00 EAN 8 D...

Page 105: ...8 Both Guards Substitution Enables disables the ability of the reader to find an EAN JAN8 guard pattern in caseswhere the EAN JAN8 margin makes the guard look like a character C8B3B00 Expand EAN 8 to...

Page 106: ...therwise full strike EAN 8 segment EAN 8 Guard Substitution Enables disables the ability of the reader to substitute guard pattern for even parity 6 when an EAN JAN8 label is presented C8BGI00 EAN 8 G...

Page 107: ...an EAN JAN8 label segment in order for the reader to accept the segment for decoding C8BSB05 EAN 8 Minimum Segment Length Block 5 C8BSB06 EAN 8 Minimum Segment Length Block 6 C8BSB07 EAN 8 Minimum Seg...

Page 108: ...cont EAN 8 Minimum Segment Length Block cont C8BSB0B EAN 8 Minimum Segment Length Block 11 C8BSB0C EAN 8 Minimum Segment Length Block 12 C8BSB0D EAN 8 Minimum Segment Length Block 13 C8BSB0E EAN 8 Min...

Page 109: ...Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read C8BMR01 EAN 8 Minimum Reads 1 C8BMR02 EAN 8 Minimu...

Page 110: ...ves together which may have differing char acters in them NOTE The label halves being stitched together to assemble a complete label must have the structure GddddC and CddddG C8BSE00 EAN 8 Stitch Exac...

Page 111: ...will not read EAN two label bar codes EAN Two Label Combined Transmission This feature enables disables transmission of an EAN two label pair as one label tHE LABEL TYPE FOR ean TWO LABEL PAIRS IS ean...

Page 112: ...Minimum Reads This feature specifies the minimum number of consecutive times an EAN two label bar code must be decoded before it is accepted as good read CN2MR01 EAN 8 Minimum Reads 1 CN2MR02 EAN 8 M...

Page 113: ...each feature description UPC EAN Decoding Level Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer s needs...

Page 114: ...ill combine label data from multiple scans when decoding Enabling correlation will help the reader read labels that have some spots and or voids It may also help read labels that have damaged areas En...

Page 115: ...heck digit calculation Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation CPW...

Page 116: ...tings cont UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read CABMR01 UPC A Minimum Reads 1 CABMR02 UPC...

Page 117: ...s Enables disables the ability to stitch exact UPC A EAN 13 label halves with no overlapping characters NOTE The segment must have the structure GddddddCdddddd or ddddddCddddddG CUNG100 UPC EAN Guard...

Page 118: ...s the ability to stitch two UPC A EAN 13 label halves together that may have differing characters in them NOTE The label half structures must have the structure GddddddC and CddddddG The characters dC...

Page 119: ...ssary in an UPC EAN JAN label segment in order for the reader to accept the segment for decoding CUNSL05 UPC EAN Minimum Segment Length Block 5 CUNSL06 UPC EAN Minimum Segment Length Block 6 CUNSL07 U...

Page 120: ...tings cont UPC EAN Minimum Segment Length cont CUNSL0B UPC EAN Minimum Segment Length Block 11 CUNSL0C UPC EAN Minimum Segment Length Block 12 CUNSL0D UPC EAN Minimum Segment Length Block 13 CUNSL0E U...

Page 121: ...ming of optional and conditional add ons NOTE If a UPC EAN base label and a an add on are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded without an...

Page 122: ...2 QuickScan TM Lite QW2100 ENTER EXIT PROGRAMMING MODE Add Ons cont Optional Add ons cont CADO501 Optional Add Ons Enable P5 CADO800 Optional Add Ons Disable GS1 128 CADO801 Optional Add Ons Enable GS...

Page 123: ...option sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled CADOT01 Optional Add on Timer 10ms CADOT02 Optional Add on Timer 20ms CA...

Page 124: ...ODE Add Ons cont Optional Add On Timer cont CADOT06 Optional Add on Timer 60ms CADOT07 Optional Add on Timer 70ms CADOT0A Optional Add on Timer 100ms CADOT0C Optional Add on Timer 120ms CADOT0E Option...

Page 125: ...Reads This feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label CADM201 P2 Add Ons Minimum Reads 1 CADM202 P2 Add On...

Page 126: ...um Reads This feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label CADM501 P5 Add Ons Minimum Reads 1 CADM502 P5 Add...

Page 127: ...feature specifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label CADM801 GS1 128 Add Ons Minimum Reads 1 CADM802 GS1 128 A...

Page 128: ...led the reader will not read GS1 DataBar Omnidirectional bar codes GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional bar codes will be translated to the GS1 128 la...

Page 129: ...his feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirec tional label must be decoded before it is accepted as good read C4BMR01 GS1 DataBar Omnidirectional Minimum Reads...

Page 130: ...isable When disabled the reader will not read GS1 DataBar Expanded bar codes GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded bar codes will be translated to the GS1 128 label...

Page 131: ...Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read CXBMR01 GS1 DataBar Expanded Minimum Reads 1 CXBMR0...

Page 132: ...r variable length decoding or fixed length decoding for the GS1 Data Bar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decod...

Page 133: ...th if in Variable Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 74 characters See Set Length 1 on pa...

Page 134: ...d fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 74 characters A setting of 00 specifies to ignore this length only one fixed...

Page 135: ...able Disable When disabled the reader will not read GS1 DataBar Limited bar codes GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited bar codes will be translated to the GS1 128 lab...

Page 136: ...s This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read CLBMR01 GS1 DataBar Limited Minimum Reads 1 CLBMR02 GS1...

Page 137: ...e 127 ENTER EXIT PROGRAMMING MODE Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the reader will not read Code 39 bar codes CC3EN00 Code 39 Disable C...

Page 138: ...When disabled any check character in the label is treated as a data character CC3CC00 Code 39 Check Character Calculation Don t Calculate CC3CC01 Code 39 Check Character Calculation Calculate Std Che...

Page 139: ...r code data Code 39 Start Stop Character Transmission Enable this option to enable disable transmission of Code 39 start and stop characters CC3CT00 Code 39 Check Character Transmission Don t Send CC3...

Page 140: ...R EXIT PROGRAMMING MODE Code 39 cont Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 characters to Code 39 full ASCII characters CC3FA00 Code 39 Full ASCII Disa...

Page 141: ...lank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label CC3LO01 Code 39 Quiet Zones Quiet Zone on one side CC3LO02 Code 39 Quiet Zones Quie...

Page 142: ...e 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read CC3MR01 Code 39 Minimum Reads 1 CC3MR02 Code 39 Min...

Page 143: ...ymbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CC3DL01 Code 39 Decodi...

Page 144: ...r variable length decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decodin...

Page 145: ...h Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 0 to 50 characters See Set Length 1 on page 268 for more detaile...

Page 146: ...cludes the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore thi...

Page 147: ...ture specifies the ratio between an intercharacter space and module for Code 39 labels CC3IR00 Code 39 Interdigit Ratio Disable CC3IR01 Code 39 Interdigit Ratio 1 CC3IR02 Code 39 Interdigit Ratio 2 CC...

Page 148: ...ER EXIT PROGRAMMING MODE Code 39 cont Code 39 Interdigit Ratio cont CC3IR06 Code 39 Interdigit Ratio 6 CC3IR07 Code 39 Interdigit Ratio 7 CC3IR08 Code 39 Interdigit Ratio 8 CC3IR09 Code 39 Interdigit...

Page 149: ...ing correlation will also increase the chances that a label will be read incorrectly Code 39 Stitching This option enables disables stitching for Code 39 labels When parts of a Code 39 bar code are pr...

Page 150: ...not read Code 32 bar codes Code 32 Feature Setting Exceptions CP3EN00 Code 32 Disable CP3EN01 Code 32 Enable DEFAULT NOTE The following features are set for Code 32 by using these Code 39 settings Cod...

Page 151: ...acter along with Code 32 bar code data Code 32 Start Stop Character Transmission This option enables disable transmission of Code 32 start and stop characters CP3CT00 Code 32 Check Character Transmiss...

Page 152: ...Code 39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 128 The following options apply to the Code 128 symbology Code 128 Enable Disable When disabled the...

Page 153: ...de 128 label shall be set to Code 39 and all Code 39 formatting con trol shall be applied to the label Code 128 Check Character Transmission Enable this option to transmit the check character along wi...

Page 154: ...2 3 and 4 Code 128 Sub Code Change Transmission Enables disables the transmission of Sub Code exchange characters NOT transmitted by standard decoding CC8TF00 Code 128 Function Character Transmission...

Page 155: ...es are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label CC8LO00 Code 128 Quiet Zones No Quiet Zones CC8LO01 Code 128 Quiet Zones Qu...

Page 156: ...128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read CC8MR01 Code 128 Minimum Reads 1 CC8MR02 Code 128 M...

Page 157: ...mbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CC8DL01 Code 128 Decodi...

Page 158: ...variable length decoding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decodin...

Page 159: ...gth Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 80 characters See Set Length 1 on page 268 for more detai...

Page 160: ...gth if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 80 characters A setting of 00 specifies to ignore this length only one fixed length See...

Page 161: ...g correlation will also increase the chances that a label will be read incorrectly Code 128 Stitching This option enables disables stitching for Code 128 labels When parts of a Code 128 bar code are p...

Page 162: ...ion enables disables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 dat...

Page 163: ...153 ENTER EXIT PROGRAMMING MODE Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 bar codes CI2E...

Page 164: ...isabled any check character in label is treated as a data character CI2CC00 I 2 of 5 Check Character Calculation Disable CI2CC01 I 2 of 5 Check Character Calculation Check Standard Modulo 10 CI2CC02 I...

Page 165: ...Character Calculation cont I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 bar code data CI2CC20 I 2 of 5 Check Character Calculation Chec...

Page 166: ...ont I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read CI2MR01 I 2 of 5 Minimum Reads 1 CI2MR02...

Page 167: ...ry aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions NOTE This configuration item applies to Interle...

Page 168: ...ies either variable length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed leng...

Page 169: ...le Length Mode or the first fixed length if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two See Set...

Page 170: ...d length if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters A setting of 0 specifies to ignore this length only one fixe...

Page 171: ...ay also help read labels that have damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly I 2 of 5 Zero Pattern Enables disables ZERO Digit decoding Th...

Page 172: ...assembled by the reader s software and the data will be decoded if all bar code proofing requirements are met Interleaved 2 of 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR sy...

Page 173: ...AMMING MODE Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology Datalogic 2 of 5 Enable Disable When disabled the reader will not read Datalogic 2 of 5 bar codes CD2EN00 Dat...

Page 174: ...ic 2 of 5 check character Datalogic 2 of 5 Check Character Transmission This option enables disables transmission of an optional Datalogic 2 of 5 character CD2CC00 Datalogic 2 of 5 Check Character Cal...

Page 175: ...of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read Datalogic 2 of 5 Decoding Level CD2MR01 I 2 of 5 Minimum Reads 1 CD2MR02 I 2 of 5 Minimum Reads 2 CD2M...

Page 176: ...iable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length dec...

Page 177: ...th Mode or the first fixed length if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two See Set Length...

Page 178: ...length if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters A setting of 00 specifies to ignore this length only one fixed...

Page 179: ...racter space and module for Data logic 2 of 5 CD2IR00 Datalogic 2 of 5 Interdigit Maximum Ratio Disable CD2IR01 Datalogic 2 of 5 Interdigit Maximum Ratio 1 CD2IR02 Datalogic 2 of 5 Interdigit Maximum...

Page 180: ...terdigit Maximum Ratio cont CD2IR06 Datalogic 2 of 5 Interdigit Maximum Ratio 6 CD2IR07 Datalogic 2 of 5 Interdigit Maximum Ratio 7 CD2IR08 Datalogic 2 of 5 Interdigit Maximum Ratio 8 CD2IR09 Datalogi...

Page 181: ...ation will also increase the chances that a label will be read incorrectly Datalogic 2 of 5 Stitching This option enables disables stitching for Datalogic 2 of 5 labels When parts of a Datalogic 2 of...

Page 182: ...e this option to enables disables calculation and verification of an optional Codabar check character When disabled any check characters in the label are treated as data characters CCBEN00 Codabar Dis...

Page 183: ...r code data Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters CCBCT00 Codabar Check Character Transmission Don t Send CCB...

Page 184: ...art Stop Character Set This option specifies the format of transmitted Codabar start stop characters CCBSC00 Codabar Check Character Set ABCD TN E CCBSC01 Codabar Check Character Set ABCD ABCD CCBSC02...

Page 185: ...ING MODE Codabar cont Codabar Start Stop Character Match When enabled this option requires that start and stop characters match CCBSM00 Codabar Start Stop Character Match Don t Require Match CCBSM01 C...

Page 186: ...e blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label CCBLO01 Codabar Quiet Zones Quiet Zone on one side CCBLO02 Codabar Quiet Zones Q...

Page 187: ...ar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read CCBMR01 Codabar Minimum Reads 1 CCBMR02 Codabar Minim...

Page 188: ...symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CCBDL01 Codabar Deco...

Page 189: ...ariable length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding t...

Page 190: ...gth if in Fixed Length Mode Length includes the bar code s start stop check and data characters The length must include at least one data character The length can be set from 3 to 50 characters See Se...

Page 191: ...includes the bar code s start stop check and data characters The length must include at least one data character The length can be set from 3 to 50 characters A setting of 00 specifies to ignore this...

Page 192: ...eature specifies the ratio between an intercharacter space and module for Codabar labels CCBIR00 Codabar Interdigit Ratio Disable CCBIR01 Codabar Interdigit Ratio 1 CCBIR02 Codabar Interdigit Ratio 2...

Page 193: ...EXIT PROGRAMMING MODE Codabar cont Codabar Interdigit Ratio cont CCBIR06 Codabar Interdigit Ratio 6 CCBIR07 Codabar Interdigit Ratio 7 CCBIR08 Codabar Interdigit Ratio 8 CCBIR09 Codabar Interdigit Ra...

Page 194: ...abling correlation will also increase the chances that a label will be read incorrectly Codabar Stitching This option enables disables stitching for Codabar labels When parts of a Codabar bar code are...

Page 195: ...Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic CCBAB00 ABC Codabar Di...

Page 196: ...abar Dynamic Concatena tion Mode CCBDT05 ABC Codabar Dynamic Concatenation Timeout 50 msec CCBDT0A ABC Codabar Dynamic Concatenation Timeout 100 msec CCBDT14 ABC Codabar Dynamic Concatenation Timeout...

Page 197: ...or ending with D to be concatenated Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When disabled the reader will not read Code 11 bar codes CCBFC00 ABC Codabar Fo...

Page 198: ...er Transmission This feature enables disables transmission of an optional Code 11 check character CC1CC00 Code 11 Check Character Calculation Disable CC1CC01 Code 11 Check Character Calculation Check...

Page 199: ...11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read CC1MR01 Code 11 Minimum Reads 1 CC1MR02 Code 11 Minim...

Page 200: ...r variable length decoding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decodin...

Page 201: ...Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s check and data characters The length can be set from 2 to 50 characters See Set Length 1 on page 268 for more deta...

Page 202: ...if in Fixed Length Mode Length includes the bar code s check and data characters The length can be set from 2 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See...

Page 203: ...ture specifies the ratio between an intercharacter space and module for Code 11 labels CC1IR00 Code 11 Interdigit Ratio Disable CC1IR01 Code 11 Interdigit Ratio 1 CC1IR02 Code 11 Interdigit Ratio 2 CC...

Page 204: ...ER EXIT PROGRAMMING MODE Code 11 cont Code 11 Interdigit Ratio cont CC1IR06 Code 11 Interdigit Ratio 6 CC1IR07 Code 11 Interdigit Ratio 7 CC1IR08 Code 11 Interdigit Ratio 8 CC1IR09 Code 11 Interdigit...

Page 205: ...y decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CC1DL01 Codabar Decoding Leve...

Page 206: ...abling correlation will also increase the chances that a label will be read incorrectly Code 11 Stitching This option enables disables stitching for Code 11 labels When parts of a Code 11 bar code are...

Page 207: ...e reader will not read Standard 2 of 5 bar codes Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Standard 2 of 5 check character CS...

Page 208: ...mum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read CS2CT00 Standard 2 of 5 Check Character Transmission...

Page 209: ...length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may...

Page 210: ...able Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s check and data characters The length can be set from 1 to 50 characters See Set Length 1 on page 268 f...

Page 211: ...ed length if in Fixed Length Mode Length includes the bar code s check and data characters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed...

Page 212: ...ll also increase the chances that a label will be read incorrectly Standard 2 of 5 Stitching This option enables disables stitching for Standard 2 of 5 labels When parts of a Standard 2 of 5 bar code...

Page 213: ...es ability of reader to decode Industrial 2 of 5 labels Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 of 5 check character CU2...

Page 214: ...able length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length dec...

Page 215: ...n Variable Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 50 characters See Set Length 1 on page 268...

Page 216: ...Length includes the bar code s check data and full ASCII shift charac ters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies to...

Page 217: ...Reads This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read CU2MR01 Industrial 2 of 5 Minimum Reads 1 CU2MR02 Ind...

Page 218: ...h stitching for Industrial 2 of 5 Industrial 2 of 5 Character Correlation Enable disables character correlation for Industrial 2 of 5 CU2ST00 Industrial 2 of 5 Stitching Disable CU2ST01 Industrial 2 o...

Page 219: ...Disables the ability of the reader to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 check character CIAEN00 IATA...

Page 220: ...8 concatenation of 2 labels ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic CI8CE00 ISBN 128 Concatenation Disable CI8CE01 ISBN 128 Concatenation Enable DEFAULT...

Page 221: ...mic Concatenation Mode CI8DT05 ISBT 128 Dynamic Concatenation Timeout 50 msec CI8DT0A ISBT 128 Dynamic Concatenation Timeout 100 msec CI8DT14 ISBT 128 Dynamic Concatenation Timeout 200 msec CI8DT32 IS...

Page 222: ...e concatenated ISBT 128 Advanced Concatenation Options NOTE This option is only valid when ISBT 128 Concatenation is enabled see page 210 CI8FC00 ISBT 128 Force Concatenation Disable CI8FC01 ISBT 128...

Page 223: ...els MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check character CMSEN00 MSI Disable CMSEN01 MSI Enable DEFAULT CMSCC00 MSI Check Character Calculat...

Page 224: ...er variable length decoding or fixed length decoding for the MSI sym bology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding...

Page 225: ...or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 01 to 50 characters See Set Length 1 on page 268 for more detailed pro...

Page 226: ...es the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 0 specifies to ignore this len...

Page 227: ...t MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read CMSMR01 MSI Minimum Reads 1 CMSMR02 MSI Minimum Reads...

Page 228: ...decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CMSDL00 MSI Decoding Level Disa...

Page 229: ...93 Check Character Calculation Enables disables calculation and verification of an optional Code 93 check character CC9EN00 Code 93 Disable CC9EN01 Code 93 Enable DEFAULT CC9CC00 Code 93 Check Charact...

Page 230: ...ither variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length dec...

Page 231: ...h Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 01 to 50 characters See Set Length 1 on page 268 for more detail...

Page 232: ...cludes the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore thi...

Page 233: ...93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read CC9MR01 Code 93 Minimum Reads 1 CC9MR02 Code 93 Minim...

Page 234: ...to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CC9DL00 Code 93 Decoding Level Disable...

Page 235: ...ables disables fixed length stitching for Code 93 CC9LO00 Code 93 Quiet Zones No Quiet Zones CC9LO01 Code 93 Quiet Zones Quiet Zone on one side CC9LO02 Code 93 Quiet Zones Quiet Zones on two sides CC9...

Page 236: ...enable fixed or variable length stitching for Code 93 Code 93 Character Correlation Enables disables Character Correlation for Code 93 CC9ST00 Code 93 Stitching Disable CC9ST01 Code 93 Stitching Enabl...

Page 237: ...block F Enable Disable Enables Disables the ability of the reader to decode Codablock F labels Codablock F EAN Enable Disable Enables Disables the Codablock F EAN subtype code with FNC1 in the first p...

Page 238: ...ble length decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding t...

Page 239: ...Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 003 to 255 characters See Set Length 1 on page 268 for mor...

Page 240: ...includes the bar code s check data and full ASCII shift charac ters The length does not include start stop characters The length can be set from 3 to 255 characters A setting of 00 specifies to ignore...

Page 241: ...e Enables Disables ability of reader to decode Code 4 labels Code 4 Check Character Transmission This feature enables disables transmission of an optional Code 4 check character CCREN00 Code 4 Disable...

Page 242: ...ersion of hexidecimal label data to decimal label data Code 5 The following options apply to the Code 5 symbology Code 5 Enable Disable Enables Disables ability of reader to decode Code 5 labels CCRHD...

Page 243: ...l Code 5 check character Code 5 Hex to Decimal Conversion This feature enables disables the conversion of hexidecimal label data to decimal label data CC5CT00 Code 5 Check Character Transmission Don t...

Page 244: ...ymbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions NOTE This configuratio...

Page 245: ...ont Code 4 and Code 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read CC5MR01 Code 4 or Code 5...

Page 246: ...5 Enable Disable Enables Disables ability of reader to decode Follett 2 of 5 labels BC412 The following options apply to the BC412 symbology BC412 Enable Disable Enables Disables ability of reader to...

Page 247: ...le this option to enable disable calculation and verification of an optional BC412 check character When disabled any check character in the label is treated as a data character CBCCC00 BC412 Check Cha...

Page 248: ...412 Minimum Reads This feature specifies the minimum number of consecutive times a BC412 label must be decoded before it is accepted as good read CBCMR01 Code 39 Minimum Reads 1 CBCMR02 Code 39 Minimu...

Page 249: ...ology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 267 for more detailed programming instructions CBCDL01 Code 39 Decoding...

Page 250: ...r variable length decoding or fixed length decoding for the BC412 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding...

Page 251: ...Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 0 to 50 characters See Set Length 1 on page 268 for more detailed...

Page 252: ...des the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore this l...

Page 253: ...eference Guide 243 Chapter 11 References This section contains explanations and examples of selected bar code features See the program ming sections for the actual bar code labels used to configure th...

Page 254: ...LABEL GONE TIMEOUT SETTING 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hear a...

Page 255: ...an the appropriate three digits from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 S...

Page 256: ...continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Timeout prevents undesired multiple reads of the same label while...

Page 257: ...at repre sent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mod...

Page 258: ...Appendix E Keypad representing the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to ex...

Page 259: ...n Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to...

Page 260: ...wo digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT P...

Page 261: ...pad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This compl...

Page 262: ...ad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This comple...

Page 263: ...5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character...

Page 264: ...Keypad that repre sent the number which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programm...

Page 265: ...in Appendix E Keypad that represent the desired character value in step 1 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programmin...

Page 266: ...rs from the keypad in Appendix E Keypad that represent the desired character value in step 2 above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code...

Page 267: ...the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE...

Page 268: ...endix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit...

Page 269: ...the duration which was determined in the steps above You will hear a two beep indica tion after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This complet...

Page 270: ...to terminate the string 6 Scan the ENTER EXIT bar code once again to exit Programming Mode 7 The resulting message string would appear as follows Scanned bar code data 12345 Resulting message string...

Page 271: ...ollowed by A modifier character the modifier character is symbol dependent Figure 8 AIM ID NOTE This feature enables disables addition of AIM IDs for all symbology types SYMBOLOGY CHAR SYMBOLOGY CHAR...

Page 272: ...00 CODE11 CE 434500 b 620000 CODE128 230000 T 540000 CODE32 A 410000 X 580000 CODE39 2A0000 V 560000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 CODE93 260000 U 550000 DATALOGIC 2OF5 s 730000 s 73...

Page 273: ...SBN I 490000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 UPCA P8 A 4100...

Page 274: ...Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID...

Page 275: ...using Label ID Symbology Selection starting on page 72 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents fr...

Page 276: ...label AB12BA21 it would look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 char acters Nothing is done wit...

Page 277: ...reasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the dec...

Page 278: ...for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep i...

Page 279: ...ing Mode 3 Scan the Select Length 2 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in...

Page 280: ...References 270 QuickScan TM Lite QW2100 NOTES...

Page 281: ...Approximately 4 2 oz 119 g Color Black or White Electrical Characteristics Voltage Current 5 0 VDC 10 Max Operating Current 5V 260mA Typical Operating Scanning Current 5V 180mA Idle Operating Current...

Page 282: ...ment Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 40 to 158 F 40 to 70 C Humidity 5 to 95 relative humidity non condensing Drop Specifications Withstands multiple 5 ft 1 524 m drops...

Page 283: ...l descriptions in Table 2 apply to the connector on the reader and are for ref erence only Table 2 Standard Cable Pinouts Reader Side Cable Clip Latch To Host Cable Cable Strain Relief Bottom of Image...

Page 284: ...274 QuickScanTM Lite QW2100 NOTES...

Page 285: ...ttings for these same configurable features Table 3 Standard Defaults Parameter Default Your Setting Page Number General Features Host Commands Obey Ignore Obey 15 USB Suspend Mode Disable 16 Double R...

Page 286: ...B COM Intercharacter Delay No Delay 44 Beep On ASCII BEL Disable 45 Beep On Not on File Enable 45 ACK Character ACK 47 NAK Character NAK 47 ACK NAK Timeout Value 600 ms 48 ACK NAK Retry Count 3 Retrie...

Page 287: ...IM ID Enable 69 Label ID Control Disable 71 Set Global Mid Label ID Character s No Characters 80 Case Conversion Disable 81 Character Conversion No Char Conversion 82 Symbologies Coupon Control Enable...

Page 288: ...ission Send 94 Expand EAN 8 to EAN 13 Disable 95 EAN 8 Both Guards Substitution Disable 95 EAN 8 Guard Insertion Disable 96 EAN 8 Guard Substitution Disable 96 EAN 8 Minimum Segment Length Block 8 97...

Page 289: ...r Omnidirectional Enable Disable Disable 118 GS1 DataBar Omnidirectional GS1 128 Emulation Disable 118 GS1 DataBar Omnidirectional Minimum Reads 1 119 GS1 DataBar Expanded GS1 DataBar Expanded Enable...

Page 290: ...5 Code 39 Set Length 2 50 136 Code 39 Interdigit Ratio 4 137 Code 39 Character Correlation Disable 139 Code 39 Stitching Enable 139 Code 32 Code 32 Enable Disable Disable 140 Code 32 Check Character T...

Page 291: ...ecoding Level 3 157 I 2 of 5 Length Control Variable 158 I 2 of 5 Set Length 1 12 159 I 2 of 5 Set Length 2 100 160 I 2 of 5 Character Correlation Disable 161 I 2 of 5 Stitching Disable 162 Interleave...

Page 292: ...ar Quiet Zones Auto 176 Codabar Minimum Reads 2 177 Codabar Decoding Level 3 178 Codabar Length Control Variable 179 Codabar Set Length 1 3 180 Codabar Set Length 2 50 181 Codabar Interdigit Ratio 4 1...

Page 293: ...Decoding Level 3 199 Standard 2 of 5 Length Control Variable 199 Standard 2 of 5 Set Length 1 8 200 Standard 2 of 5 Set Length 2 50 201 Standard 2 of 5 Character Correlation Disable 202 Standard 2 of...

Page 294: ...213 MSI Check Character Calculation Enable Mod10 213 MSI Check Character Transmission Enable 214 MSI Length Control Variable 214 MSI Set Length 1 1 Character 215 MSI Set Length 2 50 Characters 216 MSI...

Page 295: ...isable Disable 231 Code 4 Check Character Transmission Enable 231 Code 4 Hex to Decimal Conversion Enable 232 Code 5 Code 5 Enable Disable Disable 232 Code 5 Check Character Transmission Enable 233 Co...

Page 296: ...nterfaces USB OEM Global Suffix No Global Suffix Double Read Timeout 500 msec Interfaces All Keyboard Wedge USB Keyboard No unique settings Interface RS232 WN Expand UPC A to EAN 13 Enable UPC E Check...

Page 297: ...Label ID Character s E GS1 DataBar Expanded Label ID Character s E GS1 DataBar Limited Label ID Character s E Character Conversion CR to Interface RS232 OPOS Baud Rate 115200 Baud Transmission Label I...

Page 298: ...E P5 Label ID Character s I EAN8 P2 Label ID Character s J EAN8 P5 Label ID Character s K EAN8 GS1 128 Label ID Character s EAN13 P2 Label ID Character s L EAN13 P5 Label ID Character s M EAN13 GS1 12...

Page 299: ...rors on the reader An optional Green Spot also performs useful functions The tables below list these indications One exception to the behaviors listed in the tables is that the reader s functions are...

Page 300: ...tinuously While in Stand Mode or Trigger Object Sense mode the green spot shall be on while in stand watch state N A N A Green Spota flashes momen tarily Upon successful read of a label the software s...

Page 301: ...d FRU1 isolation mode If the reader is reset the se quence will be repeated The following table describes the LED flashes beep codes asso ciated with an error found 1 Field Replaceable Unit FRU NUMBER...

Page 302: ...292 QuickScanTM Lite QW2100 NOTES...

Page 303: ...r codes in this appendix are typical representations for their symbology types UPC A EAN 13 Code 39 Code 128 Interleaved 2 of 5 0 12345 67890 5 3 456789 012340 123ABC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7...

Page 304: ...294 QuickScanTM Lite QW2100 Sample Bar Codes continued Code 32 Codabar Code 93 Code 11...

Page 305: ...elow see GS1 DataBar RSS on page 295 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Page 306: ...296 QuickScanTM Lite QW2100 NOTES...

Page 307: ...Product Reference Guide 297 Appendix E Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Page 308: ...298 QuickScanTM Lite QW2100 6 7 8 9 A B C...

Page 309: ...Product Reference Guide 299 D E F...

Page 310: ...300 QuickScanTM Lite QW2100 NOTES...

Page 311: ...dge and USB Keyboard platforms Control Character 00 Characters from 00 to 0x1F are sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 0...

Page 312: ...EOT C D ENQ C S E ACK C S F BEL C S G BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S...

Page 313: ...6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I...

Page 314: ...091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 1...

Page 315: ...2 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142...

Page 316: ...B LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C...

Page 317: ...er is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab S Tab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M...

Page 318: ...FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1...

Page 319: ...x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G...

Page 320: ...TM Lite QW2100 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy com ponents of Microsoft Windows in English and some other Weste...

Page 321: ...of Field 271 E Electrical Safety 272 EMI RFI 272 Error Codes 291 Errors 291 G Good Read Beeper 22 Pitch 24 25 Volume 28 Good Read Beeper 22 Good Read Beeper Pitch 24 25 Good Read Beeper Volume 28 Gree...

Page 322: ...271 RS 232 interface selection 12 RS 232 Serial Connection 6 RTS 41 S sample bar codes code 128 293 code 39 293 interleaved 2 of 5 294 select digits characters 297 Serial Output 273 Skew Yaw Tolerance...

Page 323: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Page 324: ...an Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 742 2206 latinamerica scanning datalogic com Singapore Datalogic Sca...

Reviews: