Indicate Transmission Failure
Product Reference Guide
51
ENTER/EXIT PROGRAMMING MODE
Indicate Transmission Failure
This option enables/disables the reader’s ability to sound an error beep to indicate a transmission
failure while in ACK/NAK mode.
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected. See
for more detailed programming instructions.
$CR2TF00
Indicate Transmission Failure = Disable Indication
$CR2TF01
Indicate Transmission Failure = Enable Indication
DEFAULT
NOTE
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option
has been set as 7
Data Bits.
$CR2DC
Select Disable Character Setting
DEFAULT
0x44 = Disable Character is ‘D’