Motion Features
Product Reference Guide
301
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume
that it is in a motionless condition. The range for this setting is from 500
msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
= 0005 = 00, 5 = 050, 20 = 200, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
4. Scan the bar code: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
representing the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for examples of how to set this
feature.
Table 48. Motionless Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1 sec.
10 sec
9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits)
005
010
100
250
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘0’
‘1’, ‘0’, and ‘0’
‘2’, ‘5’, and ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for PowerScan 950X Series
Page 30: ...Setup 20 PowerScan PD953X PBT950X PM950X NOTES...
Page 34: ...Configuration Using Bar Codes 24 PowerScan PD953X PBT950X PM950X NOTES...
Page 56: ...46 PowerScan PD953X PBT950X PM950X NOTES...
Page 72: ...62 PowerScan PD953X PBT950X PM950X NOTES...
Page 90: ...Enter Exit Programming Mode 80 PowerScan PD953X PBT950X PM950X NOTES...
Page 182: ...172 PowerScan PD953X PBT950X PM950X NOTES...
Page 278: ...268 PowerScan PD953X PBT950X PM950X NOTES...
Page 316: ...References 306 PowerScan PD953X PBT950X PM950X NOTES...
Page 320: ...Message Formatting 310 PowerScan PD953X PBT950X PM950X NOTES...
Page 358: ...Scancode Tables 348 PowerScan PD953X PBT950X PM950X NOTES...