82 MATRIX 450N
OUTPUTS
Two optocoupled general purpose outputs are available. The meaning of the two out-
puts Output 1 and Output 2 can be defined by the user. They are typically used to signal
the data collection result.
CBX100/500
Description
+V
Power Source - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
-V
Power Reference - Outputs
The electrical features of the outputs are the following:
Outputs 1 and 2
V
CE
= 30 Vdc max.
I
CE
= 40 mA continuous max.; 130 mA pulsed max.
V
CE saturation
= 1 Vdc max. @ 10 mA
P
D
= 90 mW Max. @ 50 °C ambient temp.
By default, Output 1 is associated with the No Read event, which activates when the
code(s) signaled by the external trigger are not decoded, and Output 2 is associated
with the Good Read event, which activates when all the selected codes are correctly
decoded.
The output signals are fully programmable being determined by the configured Activa-
tion/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the DL.CODE parameters Help On Line for further details.
Summary of Contents for matrix 450N
Page 1: ...Matrix 450N PRODUCT REFERENCE GUIDE Image Based Reader ...
Page 69: ...PRODUCT REFERENCE GUIDE 55 Figure 22 Matrix 450N LT 03x L Bracket Overall Dimensions ...
Page 88: ...74 MATRIX 450N Figure 37 ID NET Network Connections with Common Power Star Network ...
Page 92: ...78 MATRIX 450N Figure 41 NPN External Trigger Using Matrix 450N Power ...
Page 142: ...Reader 2 Reader 3 128 MATRIX 450N ...
Page 150: ...136 MATRIX 450N ...
Page 152: ...138 MATRIX 450N Open the cloned application job ...