PRODUCT REFERENCE GUIDE 137
Synchronized ID-NET Network Configurations
The Synchronized ID-NET network communications between Master and Slave are inter-
nally managed by the application software. A pre-configured job is loaded with the Syn-
chronized Layout Type and the correct Operating Mode for both the Master and Slaves
when either the Phase Mode or PackTrack Configuration is selected from the Internal
Network Setting feature.
1. Complete the configuration of all the application parameters (including Image Set-
tings) and save them to the Master with an application relative name and
with
the
option to
Clone Master configuration on Slaves
.
Figure 72 - Saving Synchronized Phase Mode Configuration to Master
2. Connect to each Slave reader via Ethernet (see note below), and set the Slave spe-
cific parameters.
NOTE
If necessary, Slave device photometric (Image Settings) parameters
must be configured separately through DL.CODE. This is preferably done
through each device’s Ethernet TCP/IP channel. If Slave devices are not
connected to Ethernet you must temporarily (manually) connect them
one by one to perform Image Settings.
Summary of Contents for matrix 450N
Page 1: ...Matrix 450N PRODUCT REFERENCE GUIDE Image Based Reader ...
Page 69: ...PRODUCT REFERENCE GUIDE 55 Figure 22 Matrix 450N LT 03x L Bracket Overall Dimensions ...
Page 88: ...74 MATRIX 450N Figure 37 ID NET Network Connections with Common Power Star Network ...
Page 92: ...78 MATRIX 450N Figure 41 NPN External Trigger Using Matrix 450N Power ...
Page 142: ...Reader 2 Reader 3 128 MATRIX 450N ...
Page 150: ...136 MATRIX 450N ...
Page 152: ...138 MATRIX 450N Open the cloned application job ...