PRODUCT REFERENCE GUIDE 11
2. Release the button to enter the Focus function. The Blue Diamonds turn on.
3. From the
Focusing and PPI Setup Chart
, position the 1 mm code at the center of
the Horizontal FOV (aligned with the laser pointers).
4. Exit the Focus function by pressing the X-PRESS push button once. The Blue Dia-
monds and laser pointers turn off.
Setup
Figure 10 - X-PRESS Interface: Setup Function
5. Enter the Setup function by pressing and holding the X-PRESS push button until
the Setup LED is on.
6. Release the button to enter the Setup function. The Setup LED will blink until the
procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are success-
fully saved in the reader memory, the Setup LED will stop blinking and Matrix
450N emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five) seconds
Matrix 450N will exit without saving the parameters to memory, the Setup LED
will stop blinking and in this case Matrix 450N emits a long low pitched beep.