MATRIX 300N™ REFERENCE MANUAL
84
5
5.3 FIELDBUS CONNECTION
In this layout a single reader functions as a Slave node on a Fieldbus network. The data is
transmitted to the Host through an accessory Fieldbus interface board installed inside the
CBX500 connection box.
Reader configuration can be accomplished through the Ethernet interface using the
DL.CODE configuration program.
Data can be transmitted on the RS232 auxiliary interface independently from the Fieldbus
interface selection to monitor data.
When One Shot or Phase Mode operating mode is used, the reader can be activated by an
External Trigger (photoelectric sensor) when the object enters its reading zone.
Figure 62
– Fieldbus Interface Point-to-Point Layout
CAB-DSxx-S
Matrix 300N
1
2
3
Fieldbus Interface (Profibus, DevicNet, etc.)
Auxiliary Serial Interface (RS232
– Data Monitor)
External Trigger (for One Shot or Phase Mode)
Host
Power
CBX500