background image

Symbologies

Product Reference Guide

221

Symbologies

Set Length

Length Control allows you to select either variable length decoding or fixed 

length decoding for the specified symbology.

Variable Length: 

For variable length decoding, a minimum and maximum length 

may be set.

Fixed Length: 

For fixed length decoding, two different lengths may be set.

Set Length 1

This feature specifies one of the bar code lengths for a given symbology. 

Length 1 is the minimum label length if in Variable Length Mode, or the first 

fixed length if in Fixed Length Mode.  
Reference the 

1D Symbologies on page 72

 section to view the selectable range 

(number of characters) for the symbology being set.
Follow these instructions to set this feature:

1. Determine the desired character length. Pad the number with leading 

zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-

ming Mode.

3. Scan the “Select Length 1 Setting” for the symbology being set.
4. Scan the appropriate two digits from the keypad in 

Appendix C

, that repre-

sent the length setting which was determined in the steps above. You will 

hear a two-beep indication after the last character.

NOTE

If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again

 

at the beginning.

5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming 

Mode.

This completes the procedure. See the table below for examples of how to set 

this feature.

Table 3. Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

52 Characters

74 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT LENGTH 1SETTING for the desired symbology

4

Scan Two Characters From 

Appendix C

 ‘0’ and ‘1’

‘0’ and ‘7’

 ‘5’ and ‘2’

 ‘7’ AND ‘4’

5

Scan ENTER/EXIT PROGRAMMING MODE

Summary of Contents for DSM0400

Page 1: ...DSM0400 Product Reference Guide Fixed Mount Area Imager Bar Code Reader ...

Page 2: ...revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Elec tronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic...

Page 3: ...gs 12 Using the Programming Bar Codes 12 Datalogic DESP protocol SDK 12 DespDemoApp 12 Datalogic Aladdin Utility 12 Interface Settings 13 Configuring Other Features 13 Software Version Transmission 13 Resetting the Product Configuration to Defaults 13 CONFIGURATION USING BAR CODES 15 Configuration Parameters 15 RS 232 ONLY Interface 17 Baud Rate 18 Data Bits 19 Stop Bits 19 Parity 20 Handshaking C...

Page 4: ...and UPC E to EAN 13 77 Expand UPC E to UPC A 78 UPC E Number System Character Transmission 78 GTIN FORMATTING 79 EAN 13 JAN 13 80 EAN 13 Enable Disable 80 EAN 13 Check Character Transmission 80 EAN 13 ISBN Conversion 81 ISSN 81 ISSN Enable Disable 81 EAN 8 JAN 8 82 EAN 8 Enable Disable 82 EAN 8 Check Character Transmission 82 Expand EAN 8 to EAN 13 82 UPC EAN GLOBAL SETTINGS 83 UPC EAN Price Weigh...

Page 5: ... Transmission 115 Standard 2 of 5 Length Control 116 Standard 2 of 5 Set Length 1 117 Standard 2 of 5 Set Length 2 118 INDUSTRIAL 2 OF 5 119 Industrial 2 of 5 Enable Disable 119 Industrial 2 of 5 Check Character Calculation 120 Industrial 2 of 5 Check Character Transmission 120 Industrial 2 of 5 Length Control 121 Industrial 2 of 5 Set Length 1 122 Industrial 2 of 5 Set Length 2 123 CODE IATA 124 ...

Page 6: ...Enable Disable 153 MSI Check Character Calculation 153 MSI Check Character Transmission 154 MSI Length Control 154 MSI Set Length 1 155 MSI Set Length 2 156 PLESSEY 157 Plessey Enable Disable 157 Plessey Check Character Calculation 158 Plessey Check Character Transmission 158 Plessey Length Control 159 Plessey Set Length 1 160 Plessey Set Length 2 161 2D Symbologies 162 2D Global Features 163 2D S...

Page 7: ...00 MICRO QR CODE 201 Micro QR Code Enable Disable 201 Micro QR Code Length Control 202 Micro QR Code Set Length 1 203 Micro QR Code Set Length 2 204 DIGITAL WATERMARK 205 OCR 206 UCC COMPOSITE 207 UCC Optional Composite Timer 207 POSTAL CODE SELECTION 208 Postnet BB Control 211 NewZealand Postal Control 211 REFERENCES 213 RS 232 Parameters 214 RS 232 Only 214 Baud Rate 214 Data Bits 214 Stop Bits ...

Page 8: ...228 DSM0400 Dimensions 229 Multi face Bracket for Mounting in 5 sides 230 Angular Mounting Bracket 231 Ergonomic Recommendations 232 Standard Cable Pinouts for DSM049X models 233 SAMPLE BAR CODES 235 1D Bar Codes 235 1D Bar Codes continued 236 GS1 DataBar RSS 237 GS1 DataBar 14 237 2D Bar Codes 238 ASCII Chart 239 KEYPAD 241 HID Variable PIN Code 243 ...

Page 9: ...l purpose applications retail and also light industrial environments Using the DSM0400 To read a symbol or capture an image simply aim the reader and trigger the scanner using the button on top or a trigger command through the commu nication interface The DSM0400 is a powerful omni directional reader so the orientation of the symbol is not important Datalogic s exclusive pat ented Green Spot for g...

Page 10: ...ur scanner There are different sections for interface types default factory settings general features data formatting and symbology specific features Chapter 4 References provides details concerning programmable features Appendix A Technical Specifications lists physical and performance charac teristics as well as environmental and regulatory specifications It also pro vides standard cable pin out...

Page 11: ...he name of the product you re looking for This allows you access to download Data Sheets Manuals Software Utilities and Drawings Hover over the Support Service menu for access to Services and Technical Support Reseller Technical Support An excellent source for technical assistance and information is an autho rized Datalogic reseller A reseller is acquainted with specific types of busi nesses appli...

Page 12: ...Introduction 4 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...

Page 13: ...lip Insert Remove cable connector Follow the steps provided in this section to connect and get your scanner up and communicating with its host 1 DSM049X Models only IMPORTANT First of all connect the Datalogic Inter face Cable not included to be selected among the possible accessories to the scanner as shown in Figure 1 To insert remove the cable insert a paper clip or similar object into the open...

Page 14: ... the socket on the RS 232 cable connector and the AC Adapter plug into a stan dard power outlet as shown in Figure 2 RS 232 The scanner can communicate with a standard RS 232 host USB Connection Connect the scanner to a USB port on the terminal PC using the USB connector at the end of the cable USB Select to communicate either by USB Composite Keyboard COM USB OEM USB COM STD or USB Keyboard only ...

Page 15: ...ckets are included for mounting the DSM0400 onto a stationary surface on all sides or with different angles Attach the desired bracket to the bottom of the reader using the provided screws as shown in the figures below See Appendix A for the mechanical drawings Multi side Mounting Bracket ...

Page 16: ...Setup 8 DSM0400 Fixed Mount Area Imager Bar Code Reader Angular Bracket 17 to 25 Angle Mounting Both Brackets applied N 4 M2x0 4X4 ISO14583 NYLOK 180 T6 SCREWS N 4 LOCK WASHERS UNI 1751 INCLUDED ...

Page 17: ... System Pattern 2D Matrix Symbol Linear Bar A red beam illuminates the label The field of view indicated by the aiming sys tem will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit If the aiming system is centered and the entire bar code is within the aiming field yo...

Page 18: ...terface configuration as descripted in Configuring the Interface default is USB composite interface Scan the appropriate barcode for your reader s interface type from the following section Configuring the Interface Scan the programming bar code from the following section which selects the appropriate interface type to match the system the scanner will be connected to Next proceed to the correspond...

Page 19: ...lect RS232 STD Select USB COM USB Com emulating RS 232 standard interface USB OEM can be used for OPOS UPOS JavaPOS Interface features starting on page 51 Select USB OEM Select USB Keyboard USB Keyboard with standard key encoding Interface features starting on page 23 USB Composite combines USB Keyboard and USB COM DEFAULT Select USB Composite ...

Page 20: ...vities such as acquisition and configuration so that DSM0400 can be controlled and configured using its communication interface with the host The SDK can also be used for software update DespDemoApp This is demo application is a GUI based software that implements the DESP library It is available for Windows platforms and for RS 232 and USB COM communication protocols This application covers all th...

Page 21: ...require Configuration Using Bar Codes General Features includes programming for scan ning speaker and LED indicators and other such universal settings Reading Parameters Reading Parameters include programming for scanning speaker and LED indicators and other universal settings 2D Symbologies Includes options concerning the bar code label types symbolo gies These settings allow you to enable disabl...

Page 22: ...ports either DM configuration or C128 configuration barcodes In this manual only C128 labels are included The DSM0400 default uses C128 labels for configuration To switch back and forth between the two barcode types scan the following barcodes C128 switches to DM configuration DM switches to C128 configuration ...

Page 23: ... to meet your application needs Refer to Resetting the Product Configuration to Defaults on page 13 for initial configuration in order to set the default values and select the interface for your application The following configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group Interface Configuration RS 232 ONLY Interface on ...

Page 24: ...to set the desired programming feature You may need to cover unused bar codes on the page and possibly the facing page to ensure that the scanner reads only the bar code you intend to scan 3 If additional input parameters are needed go to Appendix C and scan the appropriate characters from the keypad NOTE Additional information about many features can be found in Chapter 4 References If you make a...

Page 25: ... programming bar codes in this chapter if modifications to the standard RS 232 interface settings are necessary to meet your system s requirements BAUD RATE on page 18 DATA BITS on page 19 STOP BITS on page 19 PARITY on page 20 HANDSHAKING CONTROL on page 21 ...

Page 26: ...s of data transmitted per second Set the scan ner s baud rate to match the baud rate setting of the host device With an improper baud rate setting data may not reach the host correctly Baud Rate 1200 Baud Rate 2400 Baud Rate 4800 Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 DEFAULT ...

Page 27: ...ts DEFAULT Stop Bits The stop bit s at the end of each transmitted character marks the end of trans mission of one character and prepares the receiving device for the next charac ter in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommo date Set the number of stop bits to match host device requirements DEFAULT 1 ...

Page 28: ...the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0 or 1 based on data to ensure that an even number of 1 bits are contained in the coded character D...

Page 29: ... Send RTS and Clear to Send CTS Handshaking Control includes the following options None No HW flow control RTS RTS is asserted during transmissions CTS is ignored RTS CTS RTS is asserted during transmissions CTS gates transmis sions RTS On CTS RTS is always asserted CTS gates transmissions DEFAULT Handshaking Control None Handshaking Control RTS Handshaking Control RTS CTS Handshaking Control RTS ...

Page 30: ...22 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...

Page 31: ...ar codes in this chapter to select options for USB Key board only Interface COUNTRY MODE on page 24 SETTING ALT INPUT TYPE on page 46 SETTING ALT OUTPUT TYPE on page 46 KEYBOARD NUMERIC KEYPAD on page 47 KEYBOARD SEND CONTROL CHARACTERS on page 47 USB KEYBOARD SPEED on page 48 ...

Page 32: ...ader Country Mode This feature specifies the country language supported by the keyboard The Country Mode setting is ignored if the interface uses alternate key encod ing Setup on PC to use ALT Universal 1 Open Registry Edit 2 Set EnableHexNumpad to 1 as follows 3 Reset the PC ...

Page 33: ...Enter Exit Programming Mode Product Reference Guide 25 Setting Country Mode DEFAULT United States French International Belgian French United Kingdom Danish French France German Italian ...

Page 34: ...Enter Exit Programming Mode 26 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Norwegian Portuguese Portugal Spanish Swedish Swiss French Japanese ASCII Hungarian ...

Page 35: ...Enter Exit Programming Mode Product Reference Guide 27 Setting Country Mode continued Czech SlovaK Romanian Croatian Polish_214 Canadian French Win7 Lithuanian ...

Page 36: ...Enter Exit Programming Mode 28 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Vietnamese Russian Arabic 101 Chinese ASCII Thai Kedmanee Albanian Arabic 102 ...

Page 37: ...Enter Exit Programming Mode Product Reference Guide 29 Setting Country Mode continued Arabic 102 AZERTY Azeri Cyrillic Azeri Latin Belarusian Bosnian Cyrillic Bosnian Latin Bulgarian Cyrillic ...

Page 38: ...ing Mode 30 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Bulgarian Latin Canadian French Legacy Canadian Multilingual Chinese Simplified Chinese Traditional Czech Programmers Czech QWERTY ...

Page 39: ...Enter Exit Programming Mode Product Reference Guide 31 Setting Country Mode continued Dutch Netherland Estonian Faeroese Finnish French Canada 2000 XP French Canada 95 98 Galician ...

Page 40: ...Enter Exit Programming Mode 32 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Greek Greek Latin Greek Polytonic Greek220 Greek220 Latin Greek319 Greek319 Latin ...

Page 41: ...Enter Exit Programming Mode Product Reference Guide 33 Setting Country Mode continued Hebrew Israel Hungarian_101KEY Icelandic Irish Italian_142 Japanese Shift JIS Kazakh ...

Page 42: ...nter Exit Programming Mode 34 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Korean Hangul Korean ASCII Kyrgyz Cyrillic Latin America Latvian Latvian QWERTY Lithuanian_IBM ...

Page 43: ...Programming Mode Product Reference Guide 35 Setting Country Mode continued Macedonian FYROM Maltese_47KEY Mongolian Cyrillic Polish Programmer Portuguese Brazil Portuguese Brazilian ABNT Portuguese Brazilian ABNT2 ...

Page 44: ...mming Mode 36 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued Romanian Legacy Romanian Programmer Romanian Standard CKBCO0B Russian Typewriter Serbian Cyrillic Serbian Latin Slovak QWERTY ...

Page 45: ...Enter Exit Programming Mode Product Reference Guide 37 Setting Country Mode continued Slovenian Spanish Variation Swiss German Tatar Turkish F Turkish Q Ukrainian ...

Page 46: ...amming Mode 38 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Country Mode continued US Dvorak US Dvorak Left Hand US Dvorak Right Hand US English Mac US English North American US International Uzbek Cyrillic ...

Page 47: ...Enter Exit Programming Mode Product Reference Guide 39 Setting Encoding Type DEFAULT Don t use encoding UTF_8 Windows 874 Windows 932 Windows 936 Windows 949 Windows 950 ...

Page 48: ...Enter Exit Programming Mode 40 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Encoding Type continued Windows 1250 Windows 1251 Windows 1252 Windows 1253 Windows 1254 Windows 1255 Windows 1256 ...

Page 49: ...Enter Exit Programming Mode Product Reference Guide 41 Setting Encoding Type continued Windows 1257 Windows 1258 Windows 20866 ISO 8859 1 ISO 8859 2 ISO 8859 3 ISO 8859 4 ...

Page 50: ...Enter Exit Programming Mode 42 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Encoding Type continued ISO 8859 5 ISO 8859 6 ISO 8859 7 ISO 8859 8 ISO 8859 9 ISO 8859 10 ISO 8859 11 ...

Page 51: ...Enter Exit Programming Mode Product Reference Guide 43 Setting Encoding Type continued ISO 8859 13 ISO 8859 14 ISO 8859 15 ISO 8859 16 MS DOS 437 MS DOS 737 MS DOS 775 ...

Page 52: ...Enter Exit Programming Mode 44 DSM0400 Fixed Mount Area Imager Bar Code Reader Setting Encoding Type continued MS DOS 850 MS DOS 852 MS DOS 855 MS DOS 857 MS DOS 860 MS DOS 861 MS DOS 862 ...

Page 53: ...Enter Exit Programming Mode Product Reference Guide 45 Setting Encoding Type continued MS DOS 863 MS DOS 865 MS DOS 866 MS DOS 869 Mac CP10000 ...

Page 54: ...n the current Keyboard Country Disable ALT Mode DEFAULT Enable ALT Mode Setting ALT Output Type This option specifies the encode type of ALT Mode when the scanner sends Output Keyboard Data in Alt Mode Be aware that the scanner may switch auto matically between ALT mode Normal Keyboard Scancode to correctly display some characters that are not present in the current Keyboard Country ALT Codepage u...

Page 55: ... Ctrl Key ASCII characters from 00H to 0x1FH inclusive are transmitted in the format Ctrl Key Special keys are available in the range from 81H to A1 Send Ctrl Shift Key The behavior is the same as above but control keys are sent in the format Ctrl Shift Keys Send Special Function Key Send characters between 00H and 1FH according to the special function key mapping table This is used to send keys t...

Page 56: ...is option specifies the USB poll rate for a USB keyboard NOTE USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyboard Speed 3ms USB Keyboard Speed 4ms USB Keyboard Speed 5ms USB Keyboard Speed 6ms USB Keyboard Speed 7ms USB Keyboard Speed 8ms This feature applies ONLY to the USB Keyboard interface ...

Page 57: ...ide 49 USB Keyboard Speed continued USB Keyboard Speed 9ms USB Keyboard Speed 10ms USB Keyboard Speed 11ms USB Keyboard Speed 12ms USB Keyboard Speed 13ms USB Keyboard Speed 14ms USB Keyboard Speed 15ms USB Keyboard Speed 16ms USB Keyboard Speed 17ms ...

Page 58: ...Enter Exit Programming Mode 50 DSM0400 Fixed Mount Area Imager Bar Code Reader USB Keyboard Speed continued USB Keyboard Speed 18ms USB Keyboard Speed 19ms USB Keyboard Speed 20ms ...

Page 59: ...ge 52 Introduction Feature settings for USB interfaces differ depending upon which host type the scanner will be connected with Use the feature settings in this chapter to spe cifically configure for the USB OEM interface Other USB interfaces are included in the appropriate chapter for their host type ...

Page 60: ...e scanners Depending on what other scanners you may already have connected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Tabletop Scanner Handheld Scanner NOTE DEFAULT USB OEM Device Usage Tabletop Scanner USB OEM Device Usage Handheld Scanner It may be necessary to switch device usage when connecting two scanners of the same type to a POS sy...

Page 61: ...X SUFFIX on page 54 GLOBAL AIM ID on page 55 on page 56 The features in this chapter can be used to build specific user defined data into a message string See Chapter 4 References for more detailed instructions on setting these fea tures GS1 128 AIM ID ...

Page 62: ...ng your desired character s End by scanning the ENTER EXIT bar code again and then exit programming mode by scan ning it one more time Set Global Prefix Set Global Suffix To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix C represent ing your desired character s End by scanning the ENTER EXIT bar co...

Page 63: ... of AIM IDs for all symbology types AIM label identifiers as opposed to custom characters you select yourself as with label identifiers can be included with scanned bar code data See Global AIM ID on Chapter 4 References for more detailed programming instructions DEFAULT Global AIM ID Disable Global AIM ID Enable ...

Page 64: ...f Global AIM ID is disabled the AIM ID for GS1 128 can be enabled disabled independently The AIM ID for GS1 128 is a C1 C2 or C3 AIM IDs for other symbologies can be enabled disabled independently as well Contact Customer Support for assistance GS1 128 AIM ID Disable GS1 128 AIM ID Enable DEFAULT ...

Page 65: ...e 60 ENABLE DISABLE GREEN SPOT GOOD READ LED INDICA TOR on page 61 ENABLE DISABLE TRIGGER LED INDICATOR on page 61 ENABLE DISABLE POWER LED INDICATOR on page 61 SCANNING FEATURES on page 62 SCAN MODE on page 62 FLASH ON TIME on page 63 FLASH OFF TIME on page 64 STAND MODE SENSITIVITY on page 65 SCANNING ACTIVE TIME on page 66 PICK MODE on page 67 ...

Page 66: ...eads of labels of the same symbology and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Time out does not apply to scan modes that require a trigger pull for each label that is read Double Read Timeout 0 1 Second Double Read Timeout 0 2 Second Double Read Timeout 0 3 Second Double Read Timeout 0 4...

Page 67: ...eference Guide 59 Double Read Timeout continued Double Read Timeout 0 5 Second Double Read Timeout 0 6 Second Double Read Timeout 0 7 Second Double Read Timeout 0 8 Second Double Read Timeout 0 9 Second Double Read Timeout 1 Second DEFAULT ...

Page 68: ... AND SPEAKER INDICATORS Good Read Speaker Volume Selects the speaker volume loudness upon a good read beep There are three selectable volume levels Good Read Speaker Volume Speaker Off Good Read Speaker Volume Low Good Read Speaker Volume Medium Good Read Speaker Volume High DEFAULT ...

Page 69: ...n spot good read LED indicator Green Spot Disable Green Spot Enable DEFAULT Enable Disable Trigger LED indicator Enable Disable Trigger LED Indicator blue LED Trigger LED Disable Trigger LED Enable DEFAULT Enable Disable Power LED Indicator Enable Disable Power LED Indicator yellow LED Power LED Disable Power LED Enable DEFAULT ...

Page 70: ...ger Bar Code Reader SCANNING FEATURES Scan Mode Scan Mode Trigger Single DEFAULT Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode See Scan Mode on Chapter 4 References for more details ...

Page 71: ... seconds For more detailed programming instructions see Flash On Time on Chapter 4 References Select Flash ON Time Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix C represent ing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the CANCEL bar code...

Page 72: ...r setting 0 2 seconds For more detailed programming instructions see Flash Off Time on Chapter 4 References Select Flash OFF Time Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix C represent ing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the ...

Page 73: ...de Product Reference Guide 65 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and high Stand Mode Sensitivity Low Stand Mode Sensitivity Medium DEFAULT Stand Mode Sensitivity High ...

Page 74: ...es the amount of time that the reader stays in scan ON state once the state is entered Here the labels for quick configuration on 3 5 or 8 seconds More options are available using DESP or Aladdin configuration proto cols Scanning Active Time 3 seconds Scanning Active Time 5 seconds DEFAULT Scanning Active Time 8 seconds ...

Page 75: ...e close to the center of the aiming pattern This allows the reader to accurately target labels when they are placed close together such as on a pick sheet The Pick Mode can be enabled only in Trigger Single Scan Mode NOTE This feature is not compatible with Multiple Labels Reading in a Volume DEFAULT Pick Mode Disable Pick Mode Enable ...

Page 76: ...nter for all symbologies Aiming Pointer Disable Aiming Pointer Enable DEFAULT Green Spot Duration Specifies the duration of the good read pointer beam after a good read Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec DEFAULT Green Spot Duration Medium 500 msec Green Spot Duration Long 800 msec ...

Page 77: ...uct Reference Guide 69 Enhanced Mobile Phone Mode This mode is useful for improving reading performances when scanning bar codes displayed on a mobile phone DEFAULT Enhanced Mobile Phone Mode Disable Enhanced Mobile Phone Mode Enable ...

Page 78: ...e To set decoding for only 2D codes go to 2D Normal Inverse Symbol Control on page 165 For additional options see the Aladdin configuration application NOTE CAUTION Decode Negative Image Disable DEFAULT Decode Negative Image Enable When this feature is enabled you will be unable to read other program ming labels in this manual Unlike some programming features and options Decode Negative Image sele...

Page 79: ...s 1 Scan the ENTER EXIT PROGRAMMING MODE barcode below 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by scanning the ENTER EXIT PRO GRAMMING barcode ENTER EXIT PROGRAMMING MODE Disable All Symbologies NOTE This does not disable the reading of programming labels ...

Page 80: ...EAN 13 Jan 13 on page 80 ISSN on page 81 EAN 8 Jan 8 on page 82 UPC EAN Global Settings on page 83 CODE 39 on page 89 Code 32 ITAL Pharmaceutical Code on page 98 Code 39 CIP French Pharmaceutical on page 100 CODE 128 on page 101 GS1 128 on page 106 CODE ISBT 128 on page 107 INTERLEAVED 2 OF 5 I 2 OF 5 on page 109 Follett 2 of 5 on page 114 Interleaved 2 of 5 CIP HR on page 114 STANDARD 2 OF 5 on p...

Page 81: ...he top of applicable pro gramming pages 2 Scan the correct barcode to set the desired programming feature or parameter You may need to cover unused barcodes on the page and pos sibly the facing page to ensure that the reader reads only the barcode you intend to scan 3 If additional input parameters are needed go to Appendix C and scan the appropriate characters from the keypad NOTE Additional info...

Page 82: ...of processing coupon labels Coupon Control Allow all coupon barcodes to be decoded Coupon Control Enable only UPCA coupon decoding DEFAULT Coupon Control Enable only GS1 DataBar coupon decoding UPC A The following options apply to the UPC A symbology UPC A Enable Disable When disabled the reader will not read UPC A barcodes UPC A Disable UPC A Enable DEFAULT ...

Page 83: ...r along with UPC A barcode data UPC A Check Character Transmission Don t Send UPC A Check Character Transmission Send DEFAULT Expand UPC A to EAN 13 Expands UPC A data to the EAN 13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand ...

Page 84: ...ture enables disables transmission of the UPC A number system char acter UPC A Number System Character Do not transmit UPC A Number System Character Transmit DEFAULT UPC E The following options apply to the UPC E symbology UPC E Enable Disable When disabled the reader will not read UPC E barcodes UPC E Disable UPC E Enable DEFAULT ...

Page 85: ...r along with UPC E barcode data UPC E Check Character Transmission Don t Send UPC E Check Character Transmission Send DEFAULT Expand UPC E to EAN 13 Expands UPC E data to the EAN 13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand ...

Page 86: ...UPC E data to the UPC A data format DEFAULT UPC E to UPC A Don t Expand UPC E to UPC A Expand UPC E Number System Character Transmission This feature enables disables transmission of the UPC E system number char acter UPC E Number System Character Do not transmit UPC E Number System Character Transmit DEFAULT ...

Page 87: ... ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format NOTE DEFAULT GTIN Formatting Disable GTIN Formatting Enable If add on information is present on the base label prior to the conversion taking place the add on information will be appended to the converted GTIN label ...

Page 88: ...symbology EAN 13 Enable Disable When disabled the reader will not read EAN 13 JAN 13 barcodes EAN 13 Disable EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data EAN 13 Check Character Transmission Don t Send EAN 13 Check Character Transmission Send DEFAULT ...

Page 89: ...AN 13 Bookland labels starting with 978 to ISBN labels DEFAULT EAN 13 ISBN Conversion Disable EAN 13 ISBN Conversion Convert to ISBN ISSN The following options apply to the ISSN symbology ISSN Enable Disable Enables disables conversion of EAN JAN13 Bookland labels starting with 977 to ISSN labels DEFAULT ISSN Disable ISSN Enable ...

Page 90: ...JAN 8 barcodes EAN 8 Disable EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data EAN 8 Check Character Transmission Don t Send EAN 8 Check Character Transmission Send DEFAULT Expand EAN 8 to EAN 13 Enable this option to expand EAN 8 JAN 8 labels to EAN 13 JAN 13 DEFAULT Expand EAN 8 to EAN 13 Disable Expand EAN 8 ...

Page 91: ...s otherwise marked for each fea ture description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT Price Weight Check Disabled Price Weight Check 4 digit price weight check Price Weight Check 5 digit price weight check Price Weight Check European 4 digit price weight check Price Weight Check European 5 digit price weight chec...

Page 92: ... supple mentals NOTE DEFAULT Optional Add Ons Disable P2 Optional Add Ons Enable P2 DEFAULT Optional Add Ons Disable P5 Optional Add Ons Enable P5 If a UPC EAN base label and an add on are both decoded the reader will transmit the base label and add on If a UPC EAN base label is decoded without an add on the base label will be transmit ted without an add on Conditional add on settings if enabled a...

Page 93: ...r This option sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled Optional Add on Timer 10ms DEFAULT Optional Add on Timer 20ms Optional Add on Timer 30ms Optional Add on Timer 40ms Optional Add on Timer 50ms ...

Page 94: ... to disable all symbologies 1 Scan the ENTER EXIT PROGRAMMING MODE barcode below 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by scanning the ENTER EXIT PRO GRAMMING barcode ENTER EXIT PROGRAMMING MODE Disable All Symbologies NOTE This does not disable the reading of programming labels ...

Page 95: ...s Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 140ms Optional Add on Timer 160ms Enter Exit Programming Mode Product Reference Guide 87 Optional Add On Timer continued ...

Page 96: ...0ms Optional Add on Timer 220ms Optional Add on Timer 240ms Optional Add on Timer 260ms Optional Add on Timer 280ms Optional Add on Timer 300ms Enter Exit Programming Mode 88 DSM0400 Fixed Mount Area Imager Bar Code Reader Optional Add On Timer continued ...

Page 97: ... Check Character Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data character DEFAULT Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std Check Code 39 Check Character Calculation Calculate Mod 7 Check ...

Page 98: ... to transmit the check character along with Code 39 barcode data Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation continued Code 39 Check Character Calculation Enable Italian Post Check Code 39 Check Character Calculation Enable Daimler Chrysler Check ...

Page 99: ... transmission of Code 39 start and stop characters DEFAULT Code 39 Start Stop Character Transmission Don t Transmit Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters DEFAULT Code 39 Full ASCII Disable Code 39 Full ASCII Enable ...

Page 100: ...f quiet zones for Code 39 labels Quiet zones are blank areas at the ends of a bar code typically 10 times the width of the narrowest bar or space in the label Read the Enter Exit Programming Mode bar code at the top of this page and then one of the following bar codes DEFAULT Quiet zones Auto Quiet Zones Small Quiet Zones on two side ...

Page 101: ...length decoding or no check length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Code 39 Length Control Variable Length Code 39 Length Control Fixed Length DEFAULT Code 39 Length Control No check ...

Page 102: ...amming instructions see Set Length on Chapter 4 References Table 1 provides examples for setting Length 1 Table 1 Code 39 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 0 0 and 7 1 and 5 5 AND 0 5 Scan ENTER ...

Page 103: ...mming instructions see Set Length on Chapter 4 References Table 2 provides examples for setting Length 2 Table 2 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 39 LENGTH 2 SETTING 4 Scan Two Characters From Appendix C 0 and 0 0 and 7 1 and 5 5 AND 0 5 Scan...

Page 104: ... Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels DEFAULT Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Code 39 Interdigit Ratio 3 Code 39 Interdigit Ratio 4 Code 39 Interdigit Ratio 5 ...

Page 105: ...rogramming Mode Product Reference Guide 97 Code 39 Interdigit Ratio continued Code 39 Interdigit Ratio 6 Code 39 Interdigit Ratio 7 Code 39 Interdigit Ratio 8 Code 39 Interdigit Ratio 9 Code 39 Interdigit Ratio 10 ...

Page 106: ...Code 32 Italian Pharmaceutical Code sym bology Code 32 Enable Disable When disabled the reader will not read Code 32 barcodes DEFAULT Code 32 Disable Code 32 Enable Code 32 Feature Setting Exceptions NOTE The following features are set for Code 32 by using these Code 39 settings Code 39 Length Control on page 93 Code 39 Interdigit Ratio on page 96 ...

Page 107: ...e 32 barcode data DEFAULT Code 32 Check Character Transmission Don t Send Code 32 Check Character Transmission Send Code 32 Start Stop Character Transmission This option enables disables transmission of Code 32 start and stop charac ters DEFAULT Code 32 Start Stop Character Transmission Don t Trans mit Code 32 Start Stop Character Transmission Transmit ...

Page 108: ...a Imager Bar Code Reader CODE 39 CIP FRENCH PHARMACEUTICAL The following options apply to the Code 39 CIP symbology Code 39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels DEFAULT Code 39 CIP Disable Code 39 CIP Enable ...

Page 109: ...able Disable When disabled the reader will not read Code 128 barcodes Code 128 Disable Code 128 Enable DEFAULT Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data DEFAULT Code 128 Check Character Transmission Don t Send Code 128 Check Character Transmission Send ...

Page 110: ...EFAULT Code 128 Function Character Transmission Don t Send Code 128 Function Character Transmission Send Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zones Auto DEFAULT ...

Page 111: ... Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for the Code 128 symbology Code 128 Length Control Variable Length Code 128 Length Control Fixed Length DEFAULT Code 128 Length Control No Check ...

Page 112: ...nstructions see Set Length on Chapter 4 References Table 3 provides some examples for setting Length 1 Table 3 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 80 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 1 and 5 8 and 0 5 Scan ENTER EX...

Page 113: ... more detailed programming instruc tions see Set Length on Chapter 4 References Table 4 provides examples for setting Length 2 Table 4 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 80 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 128 LENGTH 2 SETTING 4 Scan Two Characters From Appendix C 0 and 0 0 and ...

Page 114: ...128 GS1 128 Enable This option enables disables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels GS1 128 Transmit in Code 128 data format GS1 128 Transmit in GS1 128 data format DEFAULT GS1 128 Do not transmit GS1 128 labels ...

Page 115: ...disable ISBT128 concatenation of 2 labels DEFAULT ISBN 128 Concatenation Disable ISBN 128 Concatenation Enable ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic NOTE DEFAULT ISBT 128 Concatenation Mode Static ISBT 128 Concatenation Mode Dynamic This option is only valid when ISBT 128 Concatenation on page 107 is enabled see page 9 107 ...

Page 116: ...c ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatenation Timeout 500 msec ISBT 128 Dynamic Concatenation Timeout 750 msec ISBT 128 Dynamic Concatenation Timeout 1 second ISBT 128 Advanced Concatenation Options NOTE To set up pairs of label types for concatenation use the Datalogic Aladdin configura tion application or ...

Page 117: ...ader will not read I 2 of 5 barcodes DEFAULT I 2 of 5 Disable I 2 of 5 Enable I 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional I 2 of 5 check character DEFAULT I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Parcel ...

Page 118: ...ith I 2 of 5 barcode data I 2 of 5 Check Character Transmission Don t Send I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Check Character Calculation continued I 2 of 5 Check Character Calculation Check DHL I 2 of 5 Check Character Calculation Check Daimler Chrysler I 2 of 5 Check Character Calculation Check Bosch I 2 of 5 Check Character Calculation Italian Post ...

Page 119: ...ength decoding or no check length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set I 2 of 5 Length Control Variable Length I 2 of 5 Length Control Fixed Length DEFAULT I 2 of 5 Length Control No Check ...

Page 120: ...amming instruc tions see Set Length on Chapter 4 References Table 5 provides some examples for setting Length 1 Table 5 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT I 2 of 5 LENGTH 1 SETTING 5 Scan Two Characte...

Page 121: ...r more detailed pro gramming instructions see Set Length on Chapter 4 References Table 6 provides examples for setting Length 2 Table 6 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT I 2 OF 5 LENGTH 2 SETTI...

Page 122: ...bles ability of imager to decode Follett 2 of 5 labels DEFAULT Follett 2 of 5 Disable Follett 2 of 5 Enable INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology Interleaved 2 of 5 CIP HR Enable Disable Enables Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels DEFAULT Interleaved 2 of 5 CIP HR Disable Interleaved 2 of 5 CIP HR Enable ...

Page 123: ...f 5 Check Character Calculation This option enables disables calculation and verification of an optional Stan dard 2 of 5 check character DEFAULT Standard 2 of 5 Check Character Calculation Disable Standard 2 of 5 Check Character Calculation Enable Standard 2 of 5 Check Character Transmission This feature enables disables transmission of an optional Standard 2 of 5 check character Standard 2 of 5 ...

Page 124: ...length decoding or no check length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Standard 2 of 5 Length Control Variable Length Standard 2 of 5 Length Control Fixed Length DEFAULT Standard 2 of 5 Length Control No Check ...

Page 125: ...ctions see Set Length on Chapter 4 Refer ences Table 7 provides some examples for setting Length 1 Table 7 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 1 and 5 5 AND 0 5 Sca...

Page 126: ...For more detailed programming instructions see Set Length on Chapter 4 References Table 8 provides examples for setting Length 2 Table 8 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 Scan Two C...

Page 127: ...ide 119 INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology Industrial 2 of 5 Enable Disable Enables Disables ability of reader to decode Industrial 2 of 5 labels DEFAULT Industrial 2 of 5 Disable Industrial 2 of 5 Enable ...

Page 128: ...al Industrial 2 of 5 check character DEFAULT Industrial 2 of 5 Check Character Calculation Disable Industrial 2 of 5 Check Character Calculation Enable Industrial 2 of 5 Check Character Transmission Enables disables transmission of an Industrial 2 of 5 check character Industrial 2 of 5 Check Character Transmission Disable Industrial 2 of 5 Check Character Transmission Enable DEFAULT ...

Page 129: ...decoding or no check length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Industrial 2 of 5 Length Control Variable Length Industrial 2 of 5 Fixed Length DEFAULT Industrial 2 of 5 Length Control No Check ...

Page 130: ...instructions see Set Length on Chapter 4 References Table 9 provides some examples for setting Length 1 Table 9 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 0 0 and 7 1 and 5 5 A...

Page 131: ...ength only one fixed length For more detailed programming instructions see Set Length on Chapter 4 References Table 10 provides examples for setting Length 2 Table 10 Industrial 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 ...

Page 132: ...y IATA Enable Disable Enables Disables the ability of the reader to decode IATA labels DEFAULT IATA Disable IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 check character IATA Check Character Transmission Disable IATA Check Character Transmission Enable DEFAULT ...

Page 133: ...bled the reader will not read Datalogic 2 of 5 barcodes DEFAULT Datalogic 2 of 5 Disable Datalogic 2 of 5 Enable Datalogic 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Data logic 2 of 5 check character DEFAULT Datalogic 2 of 5 Check Character Calculation Disable Datalogic 2 of 5 Check Character Calculation Enable ...

Page 134: ...ength decoding or no check length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Datalogic 2 of 5 Length Control Variable Length Datalogic 2 of 5 Length Control Fixed Length DEFAULT Datalogic 2 of 5 Length Control No Check ...

Page 135: ...hapter 4 References Table 11 provides some examples for setting Length 1 Table 11 Datalogic 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 02 06 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT Datalogic 2 of 5 LENGTH 1 SETTING 5 Scan Two Characters From Appendix C 0 a...

Page 136: ... more detailed programming instructions see Set Length on Chapter 4 References Table 12 provides examples for setting Length 2 Table 12 Datalogic 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14 Characters 50 Characters 2 Pad with leading zeroes to yield two digits 00 04 14 50 3 Scan ENTER EXIT PROGRAMMING MODE 4 Scan SELECT DATALOGIC 2 OF ...

Page 137: ...dabar Enable Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label is treated as a data character DEFAULT Codabar Check Character Calculation Don t Calculate Codabar Check Character Calculation Enable AIM standard check char Codabar Check Character Calculation Ena...

Page 138: ...ng with Codabar barcode data Codabar Check Character Transmission Don t Send Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codabar start and stop characters Codabar Start Stop Character Transmission Don t Trans mit Codabar Start Stop Character Transmission Transmit DEFAULT ...

Page 139: ...t Stop Character Match Don t Require Match Codabar Start Stop Character Match Require Match Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the nar rowest bar or space in the label Codabar Quiet Zones Auto DEFAULT Codabar Quiet Zones Small Quiet Zones on two sides ...

Page 140: ...le length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Codabar Length Control Variable Length Codabar Length Control Fixed Length DEFAULT Codabar Length Control No Check ...

Page 141: ...d programming instructions see Set Length on Chapter 4 References Table 13 provides some examples for setting Length 1 Table 13 Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting and pad with leading zeroes 03 Characters 09 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 a...

Page 142: ...s length only one fixed length For more detailed programming instructions see Set Length on Chapter 4 References Table 14 provides examples for setting Length 2 Table 14 Codabar Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting and pad with leading zeroes 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODABAR LENGTH 2...

Page 143: ...bology ABC Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT ABC Codabar Disable ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT ABC Codabar Concatenation Mode Static ABC Codabar Concatenation Mode Dynamic ...

Page 144: ...ks used by the ABC Codabar Dynamic Concatenation Mode ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT ABC Codabar Dynamic Concatenation Timeout 200 msec ABC Codabar Dynamic Concatenation Timeout 500 msec ABC Codabar Dynamic Concatenation Timeout 750 msec ABC Codabar Dynamic Concatenation Timeout 1 Second ...

Page 145: ...amming Mode Product Reference Guide 137 ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated DEFAULT ABC Codabar Force Concatenation Disable ABC Codabar Force Concatenation Enable ...

Page 146: ... will not read Code 11 barcodes DEFAULT Code 11 Disable Code 11 Enable Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character Code 11 Check Character Calculation Disable Code 11 Check Character Calculation Check C Code 11 Check Character Calculation Check K Code 11 Check Character Calculation Check C and K DEFAULT ...

Page 147: ...ransmission Send DEFAULT Code 11 Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Code 11 Length Control Variable Length Code 11 Length Control Fi...

Page 148: ...uctions see Set Length on Chapter 4 References Table 15 provides some examples for setting Length 1 Table 15 Code 11 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 02 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 11 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 2 0 and 7 1 and 5 5 ...

Page 149: ...iled programming instructions see Set Length on Chapter 4 References Table 16 provides examples for setting Length 2 Table 16 Code 11 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 11 LENGTH 2 SETTING 4 Scan Two Characters From Appendix C 0...

Page 150: ...ble Disable When disabled the reader will not read GS1 DataBar Omnidirectional bar codes DEFAULT GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulation When enabled GS1 DataBar Omnidirectional barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Omnidirectional GS1 128 Emulation Disable GS1 DataBar Omnidirect...

Page 151: ...d Enable Disable When disabled the reader will not read GS1 DataBar Expanded barcodes DEFAULT GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 DataBar Expanded barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Expanded GS1 128 Emulation Disable GS1 DataBar Expanded GS1 128 Emulation Enable ...

Page 152: ...ength decoding or no check length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set GS1 DataBar Expanded Length Control Variable Length GS1 DataBar Expanded Length Control Fixed Length DEFAULT GS1 DataBar Expanded Length Control No check ...

Page 153: ...see Set Length on Chapter 4 Refer ences Table 17 provides some examples for setting Length 1 Table 17 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 52 Characters 74 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar EXPANDED LENGTH 1SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 5 and 2 7 AND 4 5...

Page 154: ...ixed length For more detailed programming instructions see Set Length on Chapter 4 References Table 18 provides examples for setting Length 2 Table 18 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 ignore sec ond length 07 Characters 52 Characters 74 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING 4 Scan Tw...

Page 155: ...ted Enable Disable When disabled the reader will not read GS1 DataBar Limited barcodes DEFAULT GS1 DataBar Limited Disable GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limited barcodes will be translated to the GS1 128 label data format DEFAULT GS1 DataBar Limited GS1 128 Emulation Disable GS1 DataBar Limited GS1 128 Emulation Enable ...

Page 156: ...er to decode Code 93 labels DEFAULT Code 93 Disable Code 93 Enable Code 93 Check Character Calculation Enables disables calculation and verification of an optional Code 93 check character Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93 Check Character Calculation Enable Check K Code 93 Check Character Calculation Enable Check C and K DEFAULT ...

Page 157: ...cter Transmission Enable Code 93 Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Code 93 Length Control Variable Length Code 93 Fixed Length DEFA...

Page 158: ...nstructions see Set Length on Chapter 4 References Table 19 provides some examples for setting Length 1 Table 19 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 1 and 5 5 AND 0 5 Scan ENTER E...

Page 159: ...his length only one fixed length For more detailed program ming instructions see Set Length on Chapter 4 References Table 20 provides examples for setting Length 2 Table 20 CODE 93 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT CODE 93 LENGTH 2 SETTING 4 Scan Two Chara...

Page 160: ...er Exit Programming Mode 152 DSM0400 Fixed Mount Area Imager Bar Code Reader Code 93 Quiet Zones Enables disables quiet zones for Code 93 Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Auto DEFAULT ...

Page 161: ...eader to decode MSI labels DEFAULT MSI Disable MSI Enable MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check character MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 DEFAULT MSI Check Character Calculation Enable Mod11 10 MSI Check Character Calculation Enable Mod10 10 ...

Page 162: ...acter Transmission Enable DEFAULT MSI Length Control This feature specifies either variable length decoding fixed length de coding or no check length decoding for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set MSI Length Control Variable Length MSI Fixed Length DEFAULT MS...

Page 163: ...ructions see Set Length on Chapter 4 References Table 21 provides some examples for setting Length 1 Table 21 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 1 and 5 5 AND 0 5 Scan ENTER EXIT PROGRAM...

Page 164: ...s to ignore this length only one fixed length For more detailed pro gramming instructions see Set Length on Chapter 4 References Table 22 provides examples for setting Length 2 Table 22 MSI Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT MSI LENGTH 2 SETTING 4 Scan Two ...

Page 165: ...ming Mode Product Reference Guide 157 PLESSEY The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels DEFAULT Plessey Disable Plessey Enable ...

Page 166: ...ble Plessey Check Character Calculation Enable Plessey std check char verification DEFAULT Plessey Check Character Calculation Enable Anker check char verification Plessey Check Character Calculation Enable Plessey std and Anker check char verification Plessey Check Character Transmission Enables disables transmission of an MSI check character Plessey Check Character Transmission Disable Plessey C...

Page 167: ...g fixed length decoding or no check length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Plessey Length Control Variable Length Plessey Fixed Length DEFAULT Plessey Length Control No Check ...

Page 168: ...ailed programming instructions see Set Length on Chapter 4 References Table 23 provides some examples for setting Length 1 Table 23 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT Plessey LENGTH 1 SETTING 4 Scan Two Characters From Appendix C 0 and 1 0 and 7 1 and 5 5 A...

Page 169: ...4 References The length can be set from 1 to 50 characters A setting of 0 specifies to ignore this length only one fixed length Table 24 provides examples for setting Length 2 Table 24 Plessey Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Characters 15 Characters 50 Characters 2 Scan ENTER EXIT PROGRAMMING MODE 3 Scan SELECT PLESSEY LENGTH 2 SETTING 4 Sc...

Page 170: ...code types Symbology dependent options for each symbology are included in this chapter 2D Symbology Selection AZTEC CODE on page 166 HAN XIN CODE on page 170 DATA MATRIX on page 174 DOTCODE on page 180 MAXICODE on page 186 on page 190 MICRO PDF417 on page 193 QR CODE on page 198 MICRO QR CODE on page 201 DIGITAL WATERMARK on page 205 on page 206 UCC COMPOSITE on page 207 POSTAL CODE SELECTION on p...

Page 171: ...u may need to cover unused bar codes on the page and possibly the facing page to ensure that the reader reads only the bar code you intend to scan 3 If additional input parameters are needed go to Appendix C and scan the appropriate characters from the keypad NOTE Additional information about many features can be found in the References chapter If you make a mistake before the last character scan ...

Page 172: ... Append Enables disables ability of reader to append multiple 2D Codes labels in a structured format The structured append property is globally applied to the following symbologies if these are enabled Aztec Data Matrix PDF 417 QR Code DEFAULT Structured Append Disable Structured Append Enable ...

Page 173: ...egative printed 2D sym bols This configuration item applies globally to all the 2D symbologies that support that feature according to Standard AIM Specification Data Matrix QR MicroQR Aztec and Han Xin Code Normal Inverse Symbol Control Normal Normal Inverse Symbol Control Inverse DEFAULT Normal Inverse Symbol Control Both Normal and Inverse ...

Page 174: ... 166 DSM0400 Fixed Mount Area Imager Bar Code Reader 2D Symbology Selection AZTEC CODE Aztec Code Enable Disable Enables disables the ability of the reader to decode Aztec Code labels DEFAULT Aztec Code Disable Aztec Code Enable ...

Page 175: ... length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Aztec Code Length Control Variable Length Aztec Code Length Control Fixed Length DEFAULT Aztec Code Length Control No Check ...

Page 176: ...scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instruc tions see Set Length on Chapter 4 References Select Aztec Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ...

Page 177: ...the barcodes 0 0 0 2 for setting length 2 For more detailed pro gramming instructions see Set Length on Chapter 4 References Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENTER...

Page 178: ...ng Mode 170 DSM0400 Fixed Mount Area Imager Bar Code Reader HAN XIN CODE Han Xin Code Enable Disable Enables disables the ability of the reader to decode Han Xin Code labels DEFAULT Han Xin Code Disable Han Xin Code Enable ...

Page 179: ... length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Han Xin Code Length Control Variable Length Han Xin Code Length Control Fixed Length DEFAULT Han Xin Code Length Control No Check ...

Page 180: ...g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instruc tions see Set Length on Chapter 4 References Select Han Xin Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning ...

Page 181: ... the barcodes 0 0 0 2 for setting length 2 For more detailed pro gramming instructions see Set Length on Chapter 4 References Select Han Xin Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the EN...

Page 182: ...gramming Mode 174 DSM0400 Fixed Mount Area Imager Bar Code Reader DATA MATRIX Data Matrix Enable Disable Enables disables ability of reader to decode Data Matrix labels Data Matrix Disable Data Matrix Enable DEFAULT ...

Page 183: ... Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a bit mask to filter one or more Data Matrix labels with different symbol size AND shape styles Data Matrix Dimensions Mask Square Style Data Matrix Dimensions Mask Rectangular Style DEFAULT Data Matrix Dimensions Mask Both Square and Rectangular Style ...

Page 184: ...oding fixed length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Data Matrix Length Control Variable Length Data Matrix Length Control Fixed Length DEFAULT Data Matrix Length Control No Check ...

Page 185: ... all symbologies 1 Scan the ENTER EXIT PROGRAMMING MODE barcode below 2 Scan the Disable All Symbologies barcode 3 Complete the programming sequence by scanning the ENTER EXIT PRO GRAMMING barcode ENTER EXIT PROGRAMMING MODE Disable All Symbologies NOTE This does not disable the reading of programming labels ...

Page 186: ... scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instruc tions see Set Length on Chapter 4 References Select Data Matrix Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning th...

Page 187: ...an the barcodes 0 0 0 2 for setting length 2 For detailed program ming instructions see Set Length on Chapter 4 References Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENTER ...

Page 188: ...Code Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set DotCode Length Control Variable Length DotCode Length Control Fixed Length DEFAULT DotCode Length C...

Page 189: ...can the barcodes 0 0 0 2 for setting length 2 See Set Length on Chapter 4 References for more detailed programming instructions Select DotCode Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric characters in Appendix C representing your desired character s End by scanning the ENTER E...

Page 190: ...e four digits e g scan the barcodes 0 0 0 2 for setting length 2 See Set Length on Chapter 4 References for more detailed programming instructions Select DotCode Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric characters in Appendix C representing your desired character s End by s...

Page 191: ...s Use ful for decoding high resolution DotCode DEFAULT DotCode High Resolution Disable DotCode High Resolution Enable DotCode Constant Position Enables or disables a mode useful for decoding a series of DotCodes that will be presented in about the same area of the field of view DEFAULT DotCode Constant Position Disable DotCode Constant Position Enable ...

Page 192: ... zeroes Always use four digits e g scan the bar codes 0 0 0 2 for setting diameter 2 Default value is 0016 Maximum Dot Diameter To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric characters in Appendix C representing your desired character s End by scanning the ENTER EXIT bar code again Make a mistak...

Page 193: ...ays use four digits e g scan the bar codes 0 0 0 2 for setting diameter 2 Default value is 0001 Minimum Dot Diameter To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric characters in Appendix C representing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the ...

Page 194: ...es ability of reader to decode Maxicode labels DEFAULT Maxicode Disable Maxicode Enable Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Secondary Message is not readable DEFAULT Maxicode Primary Message Transmission Disable Maxicode Primary Message Transmission Enable ...

Page 195: ...d length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Maxicode Length Control Variable Length Maxicode Length Control Fixed Length DEFAULT Maxicode Length Control No Check ...

Page 196: ...can the barcodes 0 0 0 2 for setting length 2 For more detailed programming instruc tions see Set Length Select Maxicode Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENTER EXIT bar code again M...

Page 197: ...he barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 References Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENTER EXI...

Page 198: ...PDF417 Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set PDF417 Length Control Variable Length PDF417 Length Control Fixed Length DEFAULT PDF417 Length Co...

Page 199: ...d to be 2 710 Always use four digits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 References Select PDF417 Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desir...

Page 200: ...s of 01 Any value greater than 2 710 will be considered to be 2 710 Always use four digits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 Refer ences Select PDF417 Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu...

Page 201: ...it Programming Mode Product Reference Guide 193 MICRO PDF417 Micro PDF417 Enable Disable Enables disables the ability of the reader to decode Micro PDF417 labels DEFAULT Micro PDF417 Disable Micro PDF417 Enable ...

Page 202: ... which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID and label type Code 128 EAN128 AIM Id and label type DEFAULT Micro PDF417 Code 128 GS1 128 Emulation Micro PDF AIM ID and label type Micro PDF417 Code 128 GS1 128 Emulation Code 128 EAN128 AIM ID and label type ...

Page 203: ...ength decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Micro PDF417 Length Control Variable Length Micro PDF417 Length Control Fixed Length DEFAULT Micro PDF417 Length Control No Check ...

Page 204: ...ll be considered to be 0366 Always use four digits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 References Select Micro PDF417 Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C rep...

Page 205: ...idered to be 0366 Always use four digits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 References Select Micro PDF417 Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing ...

Page 206: ... QR Code Length Control This feature specifies either variable length decoding fixed length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set QR Code Length Control Variable Length QR Code Length Control Fixed Length DEFAULT QR Code Leng...

Page 207: ...scan the barcodes 0 0 0 2 for setting length 2 For more detailed pro gramming instructions see Set Length on Chapter 4 References Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENT...

Page 208: ...se four digits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed programming instructions see Set Length on Chapter 4 Refer ences Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End ...

Page 209: ...Programming Mode Product Reference Guide 201 MICRO QR CODE Micro QR Code Enable Disable Enables disables the ability of the reader to decode Micro QR Code labels DEFAULT Micro QR Code Disable Micro QR Code Enable ...

Page 210: ...ing fixed length decoding or no check length decoding for this symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Micro QR Code Length Control Variable Length Micro QR Code Length Control Fixed Length DEFAULT Micro QR Code Length Control No Check ...

Page 211: ...arcodes 0 0 0 2 for setting length 2 For more detailed programming instruc tions see Set Length on Chapter 4 References Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by scanning the ENTER E...

Page 212: ...gits e g scan the barcodes 0 0 0 2 for setting length 2 For more detailed pro gramming instructions see Set Length on Chapter 4 References Select Micro QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix C representing your desired charac ter s End by s...

Page 213: ...EAN 13 EAN 8 UPC A UPC E CODE 128 GS1 128 and GS1 DataBar Expanded symbologies For additional details and configuration options please contact technical support for assistance Digimarc Disable DEFAULT Digimarc Enable NOTE NOTE When enabling Digimarc also make sure that the following symbol ogies are enabled EAN 13 EAN 8 UPC A UPC E CODE 128 GS1 128 GS1 DataBar Expanded IMPORTANT For decoding Digim...

Page 214: ...ount Area Imager Bar Code Reader OCR Enables or disables the Optical Character Recognition OCR capability of the decoder For additional details and configuration options please contact techni cal support for assistance OCR Disable DEFAULT OCR Enable ...

Page 215: ...l wait for the stacked part of a UCC Composite label before transmitting the linear label without an add on DEFAULT UCC Optional Composite Timer Timer Disabled UCC Optional Composite Timer 100msec UCC Optional Composite Timer 200msec UCC Optional Composite Timer 300msec UCC Optional Composite Timer 400msec UCC Optional Composite Timer 500msec ...

Page 216: ...es the ability of the scanner to decode labels of a specific postal symbology Postnet IMB Planet Swedish Post Royal Mail Portuguese Post Kix PostNet BB Australian Post NewZealand Postal Japanese Post PostNet Enable PostNet Disable DEFAULT PlaNet Enable PlaNet Disable DEFAULT RoyalMail Enable RoyalMail Disable DEFAULT ...

Page 217: ...Programming Mode Product Reference Guide 209 Postal Code Selection continued Kix Enable Kix Disable DEFAULT Australian Post Enable Australian Post Disable DEFAULT Japanese Post Enable Japanese Post Disable DEFAULT ...

Page 218: ...sable DEFAULT Swedish Postal Enable Swedish Postal Disable DEFAULT Portugal Post Enable Portugal Post Disable DEFAULT Enter Exit Programming Mode 210 DSM0400 Fixed Mount Area Imager Bar Code Reader Postal Code Selection continued ...

Page 219: ...ontrols the ability of the scanner to decode B and B fields of Postnet labels PostNet BB Enable PostNet BB Disable DEFAULT NewZealand Postal Control Controls the ability of the scanner to decode NewZealand Postal labels NewZealand Postal Enable NewZealand Postal Disable DEFAULT ...

Page 220: ...212 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...

Page 221: ...for the actual bar code labels used to configure the scanner RS 232 Only on page 214 DATA FORMAT on page 215 Data Editing on page 215 Global Prefix Suffix on page 216 Global AIM ID on page 217 SCANNING FEATURES on page 218 Scan Mode on page 218 Flash On Time on page 219 Flash Off Time on page 220 SYMBOLOGIES on page 221 Set Length on page 221 RS 232 PARAMETERS on page 214 ...

Page 222: ...re specifies parity required for sending and receiving data A parity check bit is the most significant bit of each ASCII coded character Select the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Ev...

Page 223: ...Data Suffix AIM ID This function is used to identify and display the com mon label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data 00 20 Characters ASCII NOTE Additional advanced editing is available Contact Technical Support see page 3 for more information Please Keep In Mind Modifying a message string is not a mandatory requirement Data...

Page 224: ...BAL PREFIX bar code 3 Reference the ASCII Chart on page 239 on the inside back cover of this man ual to find the hex value assigned to the desired character The corre sponding hex number for the character is 24 To enter this selection code scan the 2 and 4 bar codes from Appendix C NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string ...

Page 225: ...onsist of three characters as follows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea a UPC A and UPC E labels are converted to EAN 13 when adding AIM IDs Code 128 GS1 128 C Code 39 and Code 32 A DataBar Omnidirectional DataBar Expanded e Codabar F Sta...

Page 226: ... label while in this mode Flashing The reader flashes1 on and off regardless of the trigger status Flash rate is controlled by Flash On Time and Flash Off Time When Flash is ON the reader reads continuously When Flash is OFF scanning is deactivated Always On No trigger pull is required to read a bar code Scanning is continu ously on Double Read Timeout prevents undesired multiple reads of the same...

Page 227: ...om the keypad in Appendix C represent ing the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This complet...

Page 228: ...igits from the keypad in Appendix C that repre sent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode Th...

Page 229: ...r example 0 00 5 05 20 20 etc 2 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 3 Scan the Select Length 1 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix C that repre sent the length setting which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake befor...

Page 230: ...ing Mode 3 Scan the Select Length 2 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix C that repre sent the length setting which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string You can the...

Page 231: ...ent Power Consumption Typical RMS Input current at 5V in Default Configuration and Trig ger Single mode DSM04x1 models USB connected Operating 244 mA Standby Idle 72 mA Low Power 3 9 mA DSM04x2 models USB connected Operating 244 mA Standby Idle 70 mA Low Power 5 mA DSM04x2 models RS232 connected Operating 276 mA Standby Idle 65 mA Low Power 9 mA if power and trigger status LED are disabled subtrac...

Page 232: ...ed Databar Expanded Databar Expanded Stacked IATA Trioptic Matrix 2 5 Telepen Composite codes CC A CC B and CC C PDF417 MicroPDF417 2D Codes China Han Xin Code Datamatrix with Chinese extension QR code Micro QR Aztec MaxiCode and Dotcode Postal Codes Australian Post British Post China Post Portugal Post Swedish Post New Zeland Post Japanese Post KIX Post IMB Planet Code Postnet Postnet BB Royal Ma...

Page 233: ...al Depth of Field Symbologya a All labels grade A ambient light level 300lux pitch angle 10 tilt angle 10 skew angle 0 room temperature 20 C Resolution mils Dmin mm Dmax mm Code 39 3 65 200 Code 39 5 35 290 Datamatrix 10 75 260 EAN13 13 45 420 Datamatrix 15 55 320 Code 39 20 b b Limited by field of view 600 DSM04X2 SR models MP Resolution 1280x960 Field of View 42 H x 32 V Typical Depth of Field S...

Page 234: ...y field of view 600 RS 232 Electrical Connections 9 pin Connector 1 Trigger DSM045X models only Trigger signal input see Figure 1 and Figure 2 2 TX Transmit Data output from scanner 3 RX Receive Data input to scanner 4 NC Not connected 5 GND Ground 6 VCC 5Vdc 7 CTS Clear to Send input to scanner 8 RTS Request to Send output from scanner Default configuration is RS 232 115200 8 N 1 no handshaking A...

Page 235: ...e indications One exception to the behaviors listed in the tables is that the reader s functions are programmable so they may or may not be turned on For example certain indications such as Green Spot GOOD green LED can be disabled using programming bar code labels Indicator Description LED Beeper Power up Reader in IDLE mode The device powers up and is ready for operation in IDLE mode POWER LED t...

Page 236: ...ther bar code type Distance between imager and bar code is incorrect Move the imager closer to or further from the bar code Bar code is decoded but not transmitted to the host Imagernotprogrammedfor the correct host type Scan the appropriate host type bar code Reader in Pro gramming mode The reader is in Program ming accepting program ming barcodes eg a enter program ming bar code is read during I...

Page 237: ...DSM0400 Dimensions Product Reference Guide 229 DSM0400 Dimensions ...

Page 238: ...Technical Specifications 230 DSM0400 Fixed Mount Area Imager Bar Code Reader Multi face Bracket for Mounting in 5 sides ...

Page 239: ...DSM0400 Dimensions Product Reference Guide 231 Angular Mounting Bracket 17 to 25 Possible Angle ...

Page 240: ...ensure that you are adhering to your company s safety programs to prevent employee injury Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clea...

Page 241: ...odel Cable clip Latch Pin Hole on the bottom side Pin 1 Pin 10 Cable To host Cable Strain Relif Interface Cable Port The signal descriptions in Table 1 apply to the connector on the scanner and are for reference only Table 1 Standard Cable Pinouts Scanner Side Pin RS 232 USB 1 RTS out 2 D 3 D 4 GND GND 5 RX 6 TX 7 VCC VCC 8 9 10 CTS in NOTE IMPORTANT DSM049X has to be used only with the Datalogic ...

Page 242: ...Technical Specifications 234 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...

Page 243: ...ce Guide 235 Appendix B Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes UPC A EAN 13 9780330290951 Code 39 Code 128 Code 128 Interleaved 2 of 5 ...

Page 244: ...Code 32 345678902 Sample Bar Codes 236 DSM0400 Fixed Mount Area Imager Bar Code Reader 1D Bar Codes continued Codabar 13579 Code 93 ABCDEF Code 11 123456779 ...

Page 245: ...taBar Expanded 1234890hjio9900mnb GS1 DataBar Limited 08672345650916 GS1 DataBar variants must be enabled to read the bar codes below see GS1 DataBar Omnidirectional on page 142 GS1 DataBar 14 GS1 DataBar Omnidirectional Truncated 55432198673467 GS1 DataBar Omnidirectional Stacked 90876523412674 GS1 DataBar Omnidirectional Stacked 78123465709811 ...

Page 246: ...400 Fixed Mount Area Imager Bar Code Reader 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF417 Car Registration PDF 417 ABCabc Micro PDF 417 BV17453 QR Code 35900G9 Micro QR Code 123456 UCC Composite ...

Page 247: ... 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d e f g h i j k l m n o p q r s t u v w x y z DEL 60 61 62 63 64 65...

Page 248: ...Sample Bar Codes 240 DSM0400 Fixed Mount Area Imager Bar Code Reader NOTES ...

Page 249: ...Product Reference Guide 241 Appendix C Keypad Use the barcodes in this appendix to enter numbers as you would select dig its characters from a keypad 0 1 2 3 4 5 ...

Page 250: ...Keypad 242 DSM0400 Fixed Mount Area Imager Bar Code Reader 6 7 8 9 ...

Page 251: ...HID Variable PIN Code Product Reference Guide 243 HID Variable PIN Code Cancel an incomplete HID Variable PIN Code Exit HID Variable PIN Code A B C D E F ...

Page 252: ...phone 39 051 3147011 Fax 39 051 3147205 2020 Datalogic S p A and or its affiliates All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U www datalogic com 820114600 RevB August 2020 ...

Reviews: