DS41
DATALOGIC
2.14 - Installation
RS232 interface
The serial interface is used in this case for point to point connections; it
handles communication with the host computer and allows both transmission
of code data and the configuration of the scanner. This is the default
interface.
The following pins of the 25-pin connector are used for RS232 interface
connection:
Pin
Name
Function
2
TX232
Transmitted Data
3
RX232
Received Data
4
RTS232
Request To Send
5
CTS232
Clear To Send
7
SGND
Signal Ground
RTS/CTS HARDWARE HANDSHAKING ENABLED
DS41
USER INTERFACE
7
SGND
SGND
RTS232
4
DCD
CTS232
5
DTR
RX232
3
TXD
TX232
2
RXD
Figure 2.15 - RS232 main interface connections