DATALOGIC
DP1100
Technical Features - 4.1
4 TECHNICAL
FEATURES
DP1100 H1
DP1100 H2
ELECTRICAL FEATURES
INPUT POWER
Supply voltage
230 Vac 50/60Hz
±
20% (184-276V)
Supply voltage
110 Vac 50/60Hz
±
20% (88-132V)
Power consumption max.
35 VA
SERIAL INTERFACES
MAIN
RS232, RS485 Non Polled,
RS485 Polled, 20 mA C. L.
AUXILIARY
RS232
BAUD RATES
All Interfaces
150 to 19200
CONTROL INPUTS
(optocoupled NPN or PNP)
1 presence sensor
1 auxiliary presence
sensor
2 presence sensors
2 auxiliary presence
sensors
Voltage max.
30 Vdc
Input current max.
20 mA
CONTROL OUTPUTS
(open emitter open collector)
No Read1
Right Read1
Right Read2
No Read
Right Read
Wrong Read
VCE max.
40 Vdc
Collector current max.
40 mA continuous; 130 mA pulsed
VCE saturation
1V at 10 mA
USER INTERFACE
LED indicators
power on, data reception, data transmission,
presence sensor active, barcode decoded