Maintenance - 3.1
3 MAINTENANCE
!
3.1
REPLACING THE PROTECTION FUSE
All the internal circuits of the DP1100 are protected by a fuse on the input
power line.
The decoder must be opened to change the fuse.
WARNING
The decoder must be disconnected from
the power supply during this operation.
Refer to paragraph 2.3 to open the decoder.
To replace the protection fuse refer to the following instructions:
1) Unscrew the screw on the protection shield indicated in figure 3.1, paying
attention to the cable which is connected to the electrical ground.
2) Remove the protection shield.
3) Replace the fuse whose position is shown in figure 3.2. Make sure to use
the correct value as specified in the protection fuse table below.
PROTECTION FUSE
230 Vac version
315 mA T
110 Vac version
500 mA T