
DP1100
DATALOGIC
2.4 - Installation
!
2.3.1 Main serial interface selection
One of the following interface types can be selected to connect the main
interface of the DP1100 to the host computer:
EIA RS232
20 mA CURRENT LOOP
EIA RS485 POLLED
EIA RS485 NON POLLED
To select the interface type, position the jumper block as indicated in the
following figure:
SW1 SW2 SW3
RS232
20 mA C.L.
RS485
POLLED
RS485
NON POLLED
SW1 SW2 SW3
Figure 2.3 - Interface type selection
NOTE
The RS232 interface type is factory set.