INITIAL SETUP
2
2 INITIAL
SETUP
For a correct DLCC configuration keep in mind the following:
•
when using the DLCC for the first time, set the desired card address via COM
Port, since its factory default address is "Undefined";
2.1 CONFIGURATION
STRINGS
When using a DLCC on a terminal or a portable PC, initial setup can be performed
via COM port by sending the configuration strings to the card using any terminal
emulation program, for example Hyper Terminal.
NOTE
Ensure that your PC COM port is set as follows:
9600 baud, no parity, 8 data bits, 1 stop bit, handshaking disabled.
The programming sequence is the following:
$+
Command
$
-
CR
Enter configuration environment
Character sequence in following tables
Exit and Save configuration
Carriage return character (0D Hex.)
Example
Command programming sequence:
$+ RC1237 $-
CR
Enter configuration environment
Carriage return character (0D Hex.)
DLCC address: 1237
Exit and Save configuration
NOTE
If you sent a wrong configuration string, you have to wait for a period
of time equal to Rx timeout (default: 5 sec.) before sending the
following configuration string.