The settings that the user can modify will appear on the screen. To move from one setting to another,
simply press the
ARROW UP/ARROW DOWN
buttons.
Parameter
Description
Change
Internal
illuminator
Select or deselect the option to enable/disable
the illuminator fitted on the sensor.
Press the
SET
button to
enable/disable the option.
External
illuminator
Select or deselect the option to enable/disable
the strobe signal that the sensor can use to pilot
the external illuminator.
Press the
SET
button to
enable/disable the option.
Exposure time
The exposure time identifies the period that the
lens remains open and allows light to reach the
CMOS mounted on the sensor. Therefore, the
longer the exposure time, the brighter the image
will be. On the other hand, increasing the
exposure times increases the risk of acquiring
blurred images where the detail being monitored
moves at a certain speed. If the images of
objects that move quickly are not very bright, it
is recommended to adjust the gain settings.
To adjust the exposure
time, move to the option
and use the
RIGHT/LEFT
ARROW
buttons.
Gain
The gain setting allows you to adjust the
brightness of the image acquired by the sensor
by amplifying the signal transmitted by the
CMOS to the processing unit. Increasing the
gain setting, however, also increases the
disturbance on the image which decreases its
quality.
To adjust the gain setting,
move to the option and use
the
RIGHT/LEFT ARROW
buttons.
Negative
Select the option to enable the inversion of the
grey tones. This creates a negative image
compared to the one currently acquired by the
sensor (i.e. white turns to black and vice-versa).
Press the
SET
button to
enable/disable the option.
Once the camera settings have been completed, it is possible to return to the Setup menu by pressing