EtherNet/IP (Net Host Port 1 only):
This enables use of
the EtherNet/IP protocol on the reader.
Message Format – Select one of four message format options
from the drop-down list:
•
Custom Message
•
Standard Message
•
User Defined Message
•
MUX (ADP) Message.
Number of Client Readers – The number of client readers in a
multi-reader network must be defined on the reader acting as
the Controller. Select the number of client readers from the
drop-down list (up to 14).
Group Number – All readers in a Controller/Client group (both
the Controller and ALL Clients) must be set to the same
controller group number. The default of zero (0) disables a
reader from listening for messages to become a client.
Controller /Client
Configuration
Redundant Controller Configuration – Select
None
,
Primary
Controller
, or
Backup Controller
from the drop-down list.
•
None:
This reader will act only as a client
•
Primary Controller:
This reader will act as the primary
controller
•
Backup Controller:
This reader will act as a backup
controller if the primary controller fails
Ethernet Link
Select
AutoDetect, 100 Mbps/Full Duplex, 100 Mbps/Half
Duplex, 10 Mbps/Full Duplex,
or
10 Mbps/Half Duplex
from
the drop-down list.
Controller
Multicast IP
Address
Enter an IP address for multicast.
Telnet Port
Enter a Telnet port ID.