98
Operations
AccuLazr™ AL5010 Product Line Manual
FieldBus LED Status Indicators
DEVICENET
Module Status Off - No power
FB1 Green Normal operation
FB1 Green, flashing Auto Baud in progress
FB2 Red Unrecoverable Fault(s) detected
FB2 Red, flashing Recoverable Fault(s) detected
Alternating Red/Green Self test in progress
Network Status Off - Not online - or - no power
FB3 Green On-line, one or more connections established
FB3 Green, flashing On-line, no connections established
FB4 Red Critical link failure
FB4 Red, flashing Connection timeout
Alternating Red/Green Self test in progress
PROFIBUS
LED State
Color
Description
FB1 Clear (0) Off
Node Off-Line or Power not supplied
Set (1) Green Node in Data Exchange Mode
Toggling (1Hz) Green, flashing Node in Clear Mode
FB2 Clear (0) Off
No Error or Power not supplied
Set (1) Red Error in initialization of PROFIBUS
ASIC
Toggling (1Hz) Red, flashing Error in configuration data and/or User
Parameterization Data