Manual Datafox EVO 3.5 Universal
Seite 15
Datum: 26.11.2018 04.03.11.XX
6.2.
Guidline for Commissioning
6.2.1. Set-up of the device
This section provides a short guideline for commissioning und links to the corresponding chapters in
the manual.
► Connecting device to current supply
► Setting interface for communication
► Loading setup of the device
See manual
6.2.2. Installation of the Device
► Installing the device at the intended location
► Establishing connections for:
o
Power:
o
Communication:
TCP/IP wlan
GPRS
RS485
o
Digital inputs
o
Digital outputs
o
Analog inputs
o
► Finishing installation of the device
► Setting for man communication
6.2.3. Troubleshooting during Commissioning
► Please see the FAQ on our website:
http://www.datafox.de/faq-de.html
► Tips:
o
Connection to the device cannot be set up via TCP/IP
Check IP in the device and the application (studio)
Ping on IP
Setting "Active Connection" in BIOS?
set to NO
Setting "HTTP" in BIOS?
set to NO