Troubleshooting
E F 3 0 1 5 S e t u p G u i d e ( R e v A )
33
Is the drive enclosure Fault/Service Required LED amber?
Answer
Possible reasons
Actions
No
System functioning properly.
No action required.
Yes (blinking) One of the following errors
occurred:
•
Hardware-controlled power-up
error
•
Cache flush error
•
Cache self-refresh error
•
Check the event log for specific information
regarding the fault.
•
Isolate the fault.
•
Contact an authorized service provider for
assistance.
•
Replace if necessary.
Yes
A fault occurred.
If installing an I/O module FRU, the
module has not gone online and
likely failed its self-test.
•
Check the event log for specific information
regarding the fault.
•
Isolate the fault.
•
Contact an authorized service provider for
assistance.
•
Replace if necessary.
•
If installing an I/O module FRU, try removing
and reinstalling the new I/O module, and
check the event log for errors.